Simplex Fire Alarm Network Reference, Network Interconnections, Physical Bridge Modules

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed Approved MEA NYC with Simplex 4120 Network additional Simplex 4120 Network connection flexibility modem communications 4120 Network topologies include ring loop star hub and Connections can include linking of two 4120 Network loops into one Total Network System linking can include passing communications up to three physical bridge links Hub nodes in the fire alarm control unit connecting to Star wiring assist in expansion and retrofit of existing 2120 Multiplex systems Refer to datasheet S4190 0016 for details on the Serial Line SLI for connection to multiple 2120 systems using a TrueSite for Simplex 4100ES 4100U and 4010ES Series fire alarm units Standard physical bridge modules include wired media modules for Network connections and a modem media module for bridge Models are available for Class B or Class X communications Fiber optic media modules can be field installed as required for 4120 communications Also compatible with legacy 4100 4100 4020 Series control units Listed to Standard 864 Connection Flexibility Physical bridge modules provide intelligent network link that increases the flexibility of Simplex 4120 Communications between the physical bridge modules a proprietary full duplex two wire modem protocol for efficient transfer Additionally each physical bridge module functions a proxy for its remote node information to maintain overall network 4120 Network Loop Connections Connection options linking of two 4120 Network loops into one network to single or multiple remote nodes using existing two wire creating hub nodes to form Star configuration systems and of these connections providing convenient networking Alarm Network Reference Bridge Modules for 4120 Network 1 bridge module link to a single remote node This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7165 0026 251 for allowable and or conditions concerning material presented in this document It is subject to re examination revision and possible cancellation Accepted for use City of New York Department of MEA35 93E Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co are the property Tyco Fire Protection Products Rev 8 11 2020 Bridge Modules for 4120 Network selection details 1 Modules for 4100ES and 4100U Bridge Class B Style 4 Bridge Class X Style 7 left port 4120 fiber media card right port 4120 fiber media card left port 4120 fiber media card left port 4120 fiber media card one modem module two wired communications two modem modules two wired communications separately as needed to wired media modules per system requirements VDC Converter Module for multiple Physical Modules 3 A maximum details 2 Modules for 4010ES Bridge Class B Style 4 Bridge Class X Style 7 left port 4120 fiber media card right port 4120 fiber media card left port 4120 fiber media card left port 4120 fiber media card one modem module two wired communications two modem modules two wired communications separately as needed to wired media modules per system requirements space slot size slot size of 1 left port and 1 port duplex fiber media per modular network card Field connections left port to right port Order fiber media kits for retrofit jobs ST connectors are already Refer to datasheet for full fiber media specifications and information block module 4 x 5 card 4100ES or 4100U only Not to 4010ES mA mA mA mA mA mA space vertical blocks mA vertical blocks mA mA mA mA mA of one left port one right port duplex media card per modular interface card Field require left port to port pairing Order fiber service kits for retrofit where ST connectors already installed Refer datasheet S4100 0056 full fiber media module and retrofit 2 Rev 8 11 2020 node connection to star topology Bridge Modules for 4120 Network 2 remote node locations to star connections Figure 2 illustrates the use of multiple physical bridge modules to allow a conventional ring topology 4120 Network to into a star topology Each physical bridge link requires a physical bridge module at each end A network interface card is required at each to complete the network communications path refer to internal block diagrams Figure 3 and Figure 4 for additional information capability This example illustrates the flexibility available when retrofitting existing Star connection topology system wiring such as for of Simplex 2120 series Multiplex fire alarm control units 3 Rev 8 11 2020 applications Bridge Modules for 4120 Network 3 illustrates network connection flexibility using physical bridges Network nodes can communicate through up to three physical bridge as indicated by the arrows Star topology bridges each link once back to the hub node and then communicate using standard 4120 wired connections the shaded section with three physical bridge links up to four separate 4120 Network loops can be connected without star connections 3 bridges physical bridge block diagram 4 bridge diagram 4 Rev 8 11 2020 additional information refer to Installation Instructions 579 184 Bridge Modules for 4120 Network distance distance B Style 4 Connection X Style 7 Connection rate temperature humidity 3 Short haul twisted pair lines AWG 9500 ft 2.85 km AWG 15,000 ft 4.5 km 4 Long haul leased telco lines 5 Connections and data information unlimited leased lines for analog data point to point full duplex no line or signaling required two wire line interface 2 wire RJ 11 Interface 2 wire RJ 11 Interfaces to 14.4 kbps to 38.4 kbps using MNP 5 compression and error correction 6 Environmental requirements to 120 0 to 49 to 93 RH non condensing at 90 32 maximum bridge hub node to multiple star connections block diagram 5 block diagram 5 Rev 8 11 2020 4120 network reference 7 Additional 4120 network reference Bridge Modules for 4120 Network Hybrid Fire Alarm Control Unit Fire Alarm Control Unit Fire Alarm Control Unit Fire Alarm Control Unit International Addressable Basic Control Unit with IDNAC Addressable Basic Control Unit with IDNAC International Physical Bridge Modules for 4120 Networks Signal Fiber Optic Modems and Accessories for 4120 networks Bridge Modules for 4120 Networks Network Interface Card BNIC Models Basic Units with ES PS Power Supplies with ES PS Power Supplies for 4120 Network Workstations Incident Commander Graphic Annunciator Graphic Annunciator Incident Commander Mobile Client Systems Integrator for ES Net and 4120 networks 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without Additional listings may be applicable conta

Related Files