Simplex Fire Suppression System Abort Switches and Releasing Appliance Circuit (RAC) Maintenance Switches; S2080-0011
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-fire-suppression-system-abort-switches-and-releasing-appliance-circuit-rac-maintenance-switches-s2080-0011-7956012384.pdf |
---|---|
Type | |
Size | 807.30 KB |
Downloads |
Text Preview
System Peripherals Fire Suppression System Abort Switches systems often require abort switches These abort are clearly labeled have a visually striking blue and combine easy operation with rugged construction high integrity operation Listed switches provide a manual fire suppression release abort request Pushbutton momentary switch is mounted on a blue Plate is flame retardant with improved impact and plate resistance A protruding collar protects the switch from contact collar is removable if required Available flush or surface mount Flush mounting requires standard single gang box Surface mounting includes a red mounting box Models are available with internal 1.2 k resistor for limited operation ULC listed to Standard S527 Abort Switch Product Selection Switches listed Status Flush mount Surface mount includes Switches for 4004R Series Suppression Release Panel Current Limited Operation size includes 3 position contact block housing one contact block installed mounting box Flush mount Surface mount includes for Field Installation Additional Contact Block for Abort Switch 1 Form C contact UL recognized component for use with these size includes 1.2 k 1W resistor for current operation and 3 position contact block housing with contact block installed mounting box Status listed listings and approvals are not applicable listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co are the property of Tyco Fire Products 3 2017 Specifications Ratings Switch One Contact block Silver contacts 1 N O 1 N C rated 2 A resistive 30 VDC Connections Switch Switch with Current Limited Information Ratings Range Range Abort Switch Installation Reference F to 120 F 0 C to 49 C to 93 at 90 32 C blocks for in out wiring 18 to 14 AWG wire 0.82 mm2 to 2.08 mm2 blocks for first wire connection 18 to 14 AWG wire 0.82 mm2 to 2.08 mm2 AWG wire lead for second wire connection Installation Instructions SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code registered trademarks of the National Fire Protection Association NFPA 2017 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Fire Protection Products Westminster MA 01441 0001 USA 3 2017