Simplex IDNet Addressable Devices, Model 4090-9007 Signal IAM (Individual Addressable Module) for use with 4100ES, 4100U, or 4010ES IDNet Communications

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Peripherals Addressable Devices Model 4090 9007 IAM Individual Addressable Module IAMs provide additional selective signaling Simplex 4007ES 4008 4010ES 4100ES and Series fire alarm control panels Signal output notification appliance circuit NAC is supervised and connected to the signal input IDNet communications control NAC output is rated 0.5 A for Special Application or 24 VDC Appliances or for audio operation W 25 VRMS 35 W 70.7 VRMS and can wired Class B or Class A see additional information page 2 specifications section Signal coding of horn strobe control strobe or other coding is provided by the input coding at the Signal IAM via IDNet communications is not supported 4100U compatibility requires Software Revision or higher Signal IAMs are not compatible with 4010 fire alarm panels IDNet communications features Relay contacts isolate signal inputs from outputs during and do not monitor signal presence signal sources will need to be monitored separately During supervision signal outputs are isolated from inputs by open contacts allowing consideration for with SCIF applications Sensitive Compartmented Facilities details Signal IAM operation is powered and supervised by the addressable communications loop separate VDC is not required for the IAM separate signal is required for the on board NAC Signal IAM communications use a single physical however each Signal IAM reduces the IDNet capacity by two addresses to accommodate the power required for output NAC supervision construction Mounts in standard 4 square electrical box Visible LED flashes to indicate communications Optional covers are available to allow LED to be after installation Screw terminals for wiring connections Listed to Standard 864 This product has been approved by the California State Fire Marshal CSFM pursuant Section 13144.1 of the California Health and Safety Code See CSFM Listings 7165 0026 251 7165 0026 318 and 7170 0026 250 for allowable and or conditions concerning material presented in this document Additional may be applicable contact your local Simplex product supplier for the latest Listings and approvals under Simplex Time Recorder Co are the property of Fire Protection Products Signal IAM approximately 1 2 size Additional NAC Operation For applications requiring individual NAC supervision and control the Signal IAM provides a 0.5 A remote NAC host panel addressable point control IDNet monitor the Signal IAM status and then the output NAC to the separate signal input for alarm notification The Signal IAM provides additional NACs to the control panel it does not provide additional power to the diagram on page 3 for additional system Control The Signal IAM also allows the control to use IDNet communications to control audio from a compatible Simplex audio control panel one signal source is used per Signal IAM separate IAMs would be required for control of DC appliances such as strobes Firefighter phone circuits are not supported Reference Selective Signaling Use Signal IAMs to provide local area notification zones per applicable of NFPA 72 the National Fire Alarm and Code local codes and system requirements Signaling Use Signal IAMs to connect to current appliances rated output is 0.5 A retrofit of Class B NAC wiring where only two wires available in out connections can be made at the IAM maintaining appliance wiring supervision per version of NFPA 72 and local codes Signal IAM operation is programmed at the fire control panel per system requirements Requirements Signal IAMS with both IDNet communications and input to the latest requirements of UL 864 to NFPA 72 per local code Please refer to the on page 3 for additional information 12 2014 Product Selection Signal IAM programming types are hardware type SIGNAL for 4008 device type SIGIAM for other compatible alarm control panels For semi flush mounted box Optional trim plate with LED viewing window includes mounting screws For surface mounted box steel Communications Isolator may be required for loop connections to Signal IAM see diagram on page 3 to data sheet S4090 0005 for details End of line resistor for Signal IAM NAC output when wired Class B 10 k 1 2 W ref 733 894 Overvoltage Protector for up to 200 mA DC or IDNet communications required where wiring exits and enters building refer to data sheet S2081 0016 for details Specifications Loading Input Choices Output Ratings Compatibility communications one address two unit loads each Signal IAM reduces the IDNet loop capacity by two addresses to the IDNet source for the total available address capacity 24 VDC from control panel NAC or NAC extender VRMS or 70.7 VRMS from compatible listed audio source Application or Regulated 24 VDC Appliances 0.5 A rating for speakers 0.5 A 25 VRMS 12.5 W or 70.7 VRMS 35 W with Simplex strobe synchronization not compatible with SmartSync 2 wire control or with TrueAlert addressable control for horn strobe appliance applications 4 wire appliances see data sheet S4903 0011 for horn control select horn operation as terminals for in out wiring 18 to 12 AWG wire 0.82 mm2 to 3.31 mm2 Class B NAC 10 k 1 2 W 4081 9008 Connections Resistor Distance Information Reference Reference Wiring Distance to diagram on 3 ft 762 m maximum distance from panel ft 3048 m maximum total wiring distance including T Taps on Class B wiring IDNet communications specifications may vary depending on the host fire alarm control refer to specific panel product documentation for details Wiring connections from the NAC Riser through the Signal IAMs and to the notification are branch circuits on the NAC Riser and must be calculated accordingly Wiring distances are limited by wire size and the allowable voltage drop from the fire alarm panel to the Signal IAM and then to the farthest notification appliance per branch The Signal IAM voltage drop is considered negligible for wiring distance Range Range Information Instructions Basic Audio Hybrid x 4 1 8 x 1 1 4 D 102 mm x 105 mm x 32 mm to 120 F 0 to 49 C indoor operation only to 93 RH at 100 F 38 C Voice Audio Panel IDNet Isolator Isolator Base Control Panel Control Panel Control Panel 12 2014 One Line Wiring Reference 2 3 Note Use 4 Wire A Vs SmartSync control with 4090 9007 4903 9426 4903 9431 4903 9433 wiring Reference Notes To determine the required NAC and IDNet wiring and survivability requirements circuit and placement and quantity of isol

Related Files