Simplex IDNet and MAPNET II Addressable Devices; Device Communications Compatibility Chart

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Peripherals and MAPNET II Addressable Devices 1 Devices compatible with 4007ES 4008 4010 4010ES 4100ES and 4100U IDNet communications and MAPNET II communications 2 Devices with special considerations 4098 9775 4098 9776 4099 9004 4099 9005 4099 9006 4099 9021 Base with LED or relay output Sensor Base with supervised relay Sensor Base Base Station Standard Station Breakglass Station Push Single Action Addressable Station 4008 4010 4010ES 4100ES and 4100U IDNet provide T sense II provides Class B monitoring of N O contacts 4100ES 4100U and 4100 use RUI 4010 uses IDNet 4008 4010 4010ES 4100ES and 4100U IDNet and MAPNET II Two addresses Does not provide TrueSense operation See below for address applications of 4098 9754 4010ES 4100ES and 4100U IDNet Uses only one address with the following sensor bases 4098 9770 4098 9771 4098 9780 4098 9791 4098 9792 4098 9793 4098 9775 4098 9776 4098 9794 4098 9797 4098 9798 4010ES 4100ES and 4100U IDNet Uses only one address with the following sensor bases 4098 9780 4098 9789 4098 9791 4098 9793 4098 9775 4098 9776 4098 9794 4010ES and 4100ES 4010ES and 4100ES 4008 4010ES 4100ES and 4100U IDNet 4008 4010ES 4100ES and 4100U IDNet requires one address but two unit loads 4010ES 4100ES and 4100U IDNet or 4100U and 4100ES MAPNET II MAPNET II requires one unit load IDNet requires two unit loads 4010ES 4100ES or 4100U IDNet or MAPNET II Operation 4008 4010 4010ES 4100ES or 4100U IDNet Operation 4010ES 4100ES and 4100U IDNet or MAPNET II Operation communications compatibility chart B IDC ZAM A IDC ZAM Sensor Housing without relay Sensor Housing with relay Sensor Housing without relay Sensor Housing with relay Sensor Base with supervised relay aspiration sensor housings 4098 XAD 110 are single inlet 4098 XAD 210 are dual inlet IAMs 4090 9051 is encapsulated without LED Addressable Controller Address Sounder Base Address Standard Base Multi Sensor for above bases Multi Sensor one address for heat and TrueSense operation sensor Multi Sensor Temperature Heat Sensor Beam Detector Communications Isolator Signal IAM mA AMZ revision 2.01 firmware Contact Relay IAM A Relay IAM LaserCOMPACT IDNet NAC Extender 4009 A 3 Devices compatible with 4007ES 4010 4010ES 4100ES and 4100U IDNet communications only except as noted 4098 9777 IAM also for use with 4008 Base also for use with 4008 Release Peripheral SRP without Uses 2975 9227 with enclosure Fiber Optic Transmitter B A Repeater Message Board 4 Devices compatible with 4007ES 4010ES 4100ES and 4100U IDNet communications only except as noted Power Isolator IAM with T Sense Input Module 4 T Sense inputs 2 relays Monitor IAM two unit loads Not with Releasing Station Push with IDNet or MAPNET II Releasing panels only S4090 0011 Rev 25 3 2022 and MAPNET II Addressable Devices 4 Devices compatible with 4007ES 4010ES 4100ES and 4100U IDNet communications only except as noted IAM with unsupervised input Mux Module internal IAM only Sensor Sounder Base Sensor Standard Base Sensor Base with 520Hz Sounder operation of some models is software revision dependent see Software Compatibility Reference for software revision compatibility details these products 4090 9116 IDNet Isolators and 4098 9777 Isolator Bases are not compatible with the 4100 3103 Quad Panel Mount Isolator Operation is with other panel modules that provide IDNet IDNet IDNet 1 IDNet 2 or IDNet 2 2 SLCs the 4190 9050 and 4190 9051 4 20 ma AMZ and 4090 9007 IDNet Signal IAM one address is assigned for IDNet communications but the SLC address count is reduced by two due to supervisory current requirements to individual product data sheets for listings information 5 Devices compatible with MAPNET II communications only refer to Table 13 for other legacy products ZAM Style D IDC ZAM Style Y NAC ZAM Style B IDC Detector ZAM IDC ZAM Style Z NAC Relay ZAM DPDT Contacts powered isolators non addressable I O Module 6 Devices compatible with 4007ES 4010 and 4010ES IDNet communications 4100ES with 2 and IDNet 2 2 Modules and 4100ES and 4100U with 4100 3106 IDNet Expansion Module Sensor uses 4098 9788 multi purpose base Sensor 2 S4090 0011 Rev 25 3 2022 communications compatibility with devices in numerical order tables in this section include legacy devices not listed in Device communications compatibility chart For currently available products see Device compatibility chart and product data sheets for additional information 7 Communications compatibility including legacy devices 4010ES 4100ES IDNet see note IDNet MAPNET II and MAPNET II Addressable Devices Station double action push no Simplex logo Station double action push Station single action Station double action breakglass Station single action LOCAL Monitor ZAM Class A IDC surface mount Monitor ZAM Class A IDC flush mount Monitor ZAM Class B IDC surface mount Monitor ZAM Class B IDC flush mount Control Relay ZAM DPDT Contacts surface mount Control Relay ZAM DPDT Contacts flush mount Detector ZAM Class B IDC surface mount Detector ZAM Class B IDC flush mount ZAM Class A NAC surface mount ZAM Class A NAC flush mount ZAM Class B NAC surface mount ZAM Class B NAC flush mount Powered Isolator non addressable surface mount Powered Isolator non addressable flush mount Addressable Module IAM includes 2190 9172A larger I O Module IDNet NAC Extender 4009A 120 VAC input IDNet NAC Extender 4009A 240 VAC input Addressable Controller 4009T Repeater Mounts in 4009A or 4009T only IAM with LED IAM Release Peripheral SRP no enclosure with enclosure Dual Contact Relay IAM A Relay IAM IAMs encapsulated without LED Class B IDC ZAM Class B IDNet Fiber Optic Transmitter Class A IDC ZAM Class A IDNet Fiber Optic Transmitter Communications Isolator see note Power Isolator IAM with T Sense Input IAM with unsupervised input Module 4 T Sense inputs 2 relays Monitor IAM 2 unit loads Duct Sensor for 4098 9701 Sensor Head 4 wire Software Compatibility

Related Files