Simplex IDNet and MAPNET II Communicating Devices, 4-20 mA Analog Monitor Zone Adapter Module (AMZ)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-idnet-and-mapnet-ii-communicating-devices-4-20-ma-analog-monitor-zone-adapter-module-amz-4576802319.pdf |
---|---|
Type | |
Size | 629.12 KB |
Downloads |
Text Preview
ULC Listed Peripherals IDNet and MAPNET II Communicating Devices mA Analog Monitor Zone Adapter Module AMZ compatible 4 20 mA output sensors linear analog sensor data to Simplex fire panel models 4007ES 4010ES and 4100ES IDNet communications and 4100ES and 4100U either IDNet or MAPNET II communications Refer to special note below for additional important detection panel monitoring and annunciation Up to three threshold levels each with custom action Display and archive actual sensor analog levels Allows sensor calibration date recording Requires a single address two IDNet unit loads Up to 100 custom AMZ point types are available per or per connected Network module features Automatic and manual AMZ self test On board manual test switch provides WALKTEST test feature Resettable sensor power output Supervised sensor trouble input Local LED alarm annunciator output Mounts in 4 102 mm square electrical box with Monitor ZAMs AMZs provide an accurate interface for connecting analog sensors to Simplex addressable fire detection panels The monitors the sensor and annunciates whenever a threshold level or trouble condition is observed applications include air quality for demand control air and liquid temperature humidity and air see listings reference on page 2 Compatible sensors are typically supplied by non SimplexGrinnell Tyco and or distributors SIMPLEXGRINNELL TYCO ALL EXPRESS WARRANTIES NOR IS IT FOR ANY SERVICE TESTING AND OR OF THE COMPATIBLE SENSORS DISCLAIMS ANY IMPLIED OF MERCHANTABILITY AND FITNESS A PARTICULAR PURPOSE REGARDING THE SENSORS Refer to listings compatibility chart on page 2 CSFM listing is not applicable for this This product was not FM approved as of revision date Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Fire Protection mA loop sensor output Surface mount AMZ LED VDC to AMZ contacts control of local functions Area communications 35 2 MONITOR STAGE 1 ALARM 4100ES fire detection showing typical message System Interface Example Application Considerations The purpose of the AMZ is to communicate the of a compatible 4 20 mA sensor to the fire detection panel for proper fire alarm response including annunciation and event Responses required to be initiated by the sensor fire and life safety actions are to be initiated sensor output contacts refer to diagram on 4 SimplexGrinnell Tyco does not assume for the application selection warranty calibration or testing of the sensor AMZs and the connected panel are to be located of the monitored area and installed in with applicable local code requirements The AMZ accommodates 2 wire 3 wire or 4 wire to a compatible sensor Depicted sensor location is for illustration only Refer to specific sensor requirements for location 11 2014 AMZ Detection Panel Features Data Access Real time analog sensor values be accessed using the front panel interface Data is in the specific units being measured Sensor Programming AMZ point types can designated as Priority 2 Supervisory Trouble Latched or Utility each with custom label For Fire Life Safety monitoring connect to sensor output refer to diagram on page 4 Communications By default the AMZ an abnormal trouble if the monitored produces an output below 4.0 mA or above mA Programmable Threshold Levels Each can have up to three separate threshold levels each a custom action message AMZ Point Types Up to 100 custom AMZ types can be programmed into a single fire alarm panel For Network applications the Network custom AMZ point type limit is also 100 maximum point types would be required for the same sensor but with different threshold values or for different with unique characteristics AMZ Product Selection Chart Date Recording Each sensor date can be manually entered for secured keeping Exporting Sensor activity pertaining to the three alarm threshold levels can be exported for via a Simplex Network using a TrueSite or TrueSite Incident Commander Compatible Sensor Operation sensors provide a linear output current between 4.0 mA and 20.0 mA that represents the analog measurement as predetermined by the sensor The AMZ monitors the 4 20 mA loop and digitally communicates the sensor to the panel With this information the can determine whether a status annunciation is and can display the sensor analog level directly the appropriate units of measurement 4 to 20 mA loop is an established analog format is highly reliable and inherently supervised for loop For additional monitoring sensors with contacts can be directly connected to the AMZ trouble input circuit Type mount Remote AMZ package with cover mounts in 4 102 mm box with extension see diagram on page 4 Coded Wire Leads AWG 0.82 mm2 LED indicator gang stainless steel plate AWG Leads AMZ Product Listings Compatibility Chart Model Listing Listing for use with Safety Appliances Co MSA model RT Refrigerant Gas Monitor for use with compatible 4 20 mA sensors 11 2014 AMZ Specifications and Current Specifications Voltage Output Current 3 or 4 wire devices AMZ Current VDC 24 VDC nominal input voltage mA maximum mA mA minimum operation below 4.0 mA is a trouble condition mA maximum operation above 20.0 mA is a trouble condition mA for monitoring of dry trouble contacts voltage supplied by the AMZ mA Loop Current Circuit Output Current LED Annunciator Specifications Trouble Input Sensor Loop and Power contact 29 VDC maximum AWG twisted pair or per sensor requirements IDNet address per AMZ two IDNet unit loads II One MAPNET II address per AMZ or MAPNET II to 100 custom AMZ point types per panel to 100 custom AMZ point types total per Network distance AMZ to sensor Range Range Instructions ft 1 km indoor locations 32 F to 120 F 0 C to 49 C to 90 RH AMZ Current Requirements Operation Loop 20 mA maximum Power 400 mA maximum LED 3 mA in alarm 5 mA with trouble contact closed Total mA mA mA mA mA mA mA Do not exceed 450 mA max 11 2014 AMZ Remote Location Mounting Information 102 mm square electrical box 54 mm deep with 1 1 2 38 mm extension supplied separately plate painted beige 4 1 2 square 114 mm mount model 4190 9050 is 3 16 4.8 mm mount model 4190 9051 is 3 64 1.2 mm switch for selection assembly includes screws switch access hole cover screws 2 supplied For additional information refer to Installation Instructions 574 704 Additional Application Reference mA loop sensor output LED RM VDC to AMZ and Six Module power input and sensor output for control of local area functions trouble or other status contact outputs