Simplex IDNet Communicating Device, Internal Addressable Manual Callpoint

File Preview
File Preview
Click below to download for free

Text Preview

IDNet I O Devices Communicating Devices Internal Addressable Manual Callpoint addressable manual fire alarm callpoints with Power and data supplied through IDNet addressable communications a single wire pair Enhanced aesthetics Designed for fast and easy installation Designed for EMI compatibility Surface or flush mounting options Test key allows the callpoint to be tested without breaking the glass Requires a special key to open the callpoint with Simplex Model series 4010 4100U 4007ES and 4100ES IDNET addressable manual callpoints with compact module install easily to satisfy demanding applications integral individual addressable module IAM monitors status and changes to the connected control panel via IDNet 1 address per callpoint switch 8 position terminals and means type connections and operating range range protection H x W x D 3 5 8 in x 3 1 2 in x 1 1 16 in to 95 RH non condensing RAL3001 to 131 10 to 55 mm x 89 mm x 28 mm 1 Addressable Manual Callpoint of the Simplex callpoint requires the glass element to be Completing the action operates a micro switch whose condition signaled back to the control panel reset requires the use of a special key supplied with the to remove the front cover which allows the glass element to be testing is performed by inserting the key fully into the bottom the housing and pulling down this releases the bottom of the housing break glass element To reset the callpoint the bottom of the is pushed upwards until it locks in position See Figure 2 This product is not presently agency listed Contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co are the property of Tyco Fire Products 2 Testing Rev 4 5 2020 Communicating Devices Internal Addressable Manual Callpoint Reference to NFPA 72 the National Fire Alarm Code and all applicable local codes for complete requirements for manual callpoints The following the basic requirements Callpoints shall be located in the normal path of exit and distributed in the protected area such that they are unobstructed and readily accessible Mounting shall be with the operable part not less than 3 1 2 ft 1.1 m and not more than 4 1 2 ft 1.37 m above floor level At least one callpoint shall be provided on each floor Additional callpoints shall be provided to obtain a travel distance not more than 200 ft to the nearest callpoint from any part of the building When manual callpoint coverage appears limited in any way additional callpoints should be installed Selection Manual Callpoints with Internal IAM callpoint with LED callpoint no LED callpoint with LED callpoint with LED callpoint with LED mount backbox for Simplex internal callpoints 32 mm deep 1 1 4 in replacement glass package of 10 Information The callpoint fits directly to a UK switch socket box A minimum box depth of 25 mm is recommended 3 PC ABS Backbox for surface mounting 2 Rev 4 5 2020 the Callpoint Address Communicating Devices Internal Addressable Manual Callpoint the Break Glass Element 4 the callpoint address 5 the Break Glass element 3 Rev 4 5 2020 Communicating Devices Internal Addressable Manual Callpoint 2020 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA Rev 4 5 2020

Related Files