Simplex IDNet Communicating Devices Addressable Manual Stations

File Preview
File Preview
Click below to download for free

Text Preview

UL ULC CSFM Listed FM Peripherals Communicating Devices Addressable Manual Stations addressable manual fire alarm stations with Power and data supplied through IDNet addressable communications a single wire pair Operation that complies with ADA requirements Pull lever that protrudes when alarmed Break rod supplied use is optional models are available Single action operation Double action operation Breakglass or Push Two stage pull station use with Simplex IDNet communications sealed construction Allows mounting in standard electrical boxes with spacer Screw terminals for wiring connections Reduces dust infiltration resistant reset key lock keyed same as Simplex fire alarm mounting options Surface or semi flush with standard or matching Simplex boxes Flush mount adapter available Adapters are available for retrofitting of existing addressable stations Simplex 4099 Series addressable stations combine the familiar manual station housing with a compact communication module is easily installed to satisfy demanding applications Its integral addressable module IAM constantly monitors status and changes to the connected control panel using Simplex communications wiring 1 addressable manual stations Figure shows Single stage Two stage Breakglass and Push manual stations of the Simplex 4099 9001 single manual station requires a downward pull to activate the alarm switch Completing the action an internal plastic break rod which is visible below the pull lever is optional The use of a break rod can be a deterrent to vandalism interfering with the minimum pull requirements needed for easy The pull lever latches into the alarm position and remains out of the housing to provide a visible indication Action Stations Breakglass require the operator to strike front mounted hammer to break the glass and expose the recessed lever The pull lever then operates as a single action station Action Stations Push Type require that a spring loaded plate marked PUSH be pushed back to access the pull of the single action station reset requires the use of a key to reset the manual station lever deactivate the alarm switch If the break rod is used it must be testing is performed by physical activation of the pull lever testing can be also performed by unlocking the station housing activate the alarm switch This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listings 7150 2269 0515 and for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product supplier for the latest status Rev 7 02 2021 addressable manual station product selection Communicating Devices Addressable Manual Stations 1 Addressable manual stations action addressable manual station action addressable manual station Breakglass operation action addressable manual station Push operation addressable manual station addressable manual station with N C Contact addressable manual station Breakglass operation addressable manual station Breakglass operation with N C Contact action addressable manual station with N C Contact action addressable manual station Breakglass operation with N C Contact action addressable manual station 2 Mounting accessories mount steel box red aluminum surface mount box red trim plate for single gang box red trim plate for Wiremold 5744 2 red mount adapter kit black mount adapter kit beige breakglass break rod key for manual station reset Figure 2 for dimensions for retrofit see Figure 3 for retrofit see Figure 3 Figure 3 for details Models shown are English Language Add for French for Bilingual for example 4099 9004CA 4099 9004CAF 4099 9004CAB and communications means connections listed temperature range range colour lever colour dimensions 3 General specifications 1 address per station up to 2500 ft 762 m from fire alarm control panel up to 10,000 ft 3048 m total distance including T Taps 8 position terminal for in out wiring for 18 to 14 AWG wire to 120 0 to 49 intended for indoor operation to 93 RH at 100 38 with white raised lettering and pull lever are Lexan polycarbonate with red raised lettering in H x 3.75 in W x 1 in D 127 mm x 95 mm x 25 mm 2 Rev 7 02 2021 references Communicating Devices Addressable Manual Stations 2 manual station mounting for 4099 9001 4099 9002 4099 9003 4 Figure reference box not furnished by Simplex by Simplex 2975 9178 or 2975 9022 top and bottom of box furnished by Simplex furnished by Simplex Refer to N B C 3.2.4.12 for requirements on manual pull stations Refer to CAN ULC S524 Section 5 2 for the requirements on the installation of pull stations 3 Rev 7 02 2021 Communicating Devices Addressable Manual Stations 3 manual station mounting for 4099 9004 4099 9005 4099 9006 4099 9007 4099 9008 4099 9009 5 Figure reference furnished by Simplex top and bottom of box furnished by Simplex or 2975 9312C furnished by Simplex Use rear conduit entry holes or back conduit holes 2021 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA Rev 7 02 2021

Related Files