Simplex Install Instructions Battery Distribution Terminal Module

File Preview
File Preview
Click below to download for free

Text Preview

4100 5128 Battery Distribution Module Instructions publication describes the installation procedure for the 4100 5128 Battery Distribution Module 450 323 The 4100 5128 is a general purpose module that can be used with utility cabinets and external battery cabinets It is always mounted to 4100 back boxes and also be mounted to 4100U and 4100ES back boxes battery distribution terminal module is shown below NUTS 2 1 4100 5128 Battery Distribution Terminal Module the the battery distribution terminal module onto the two mounting studs on the right side of back box as shown in Figure 2 2 Mounting on next page E 2005 2011 SimplexGrinnell LP All rights reserved and other information shown were current as of publication and are subject to change without notice and the Simplex logo are trademarks of Tyco International Ltd and its affiliates and are used under license Instructions Continued the 3 below shows typical battery block connections for all types of applicable cabinets Line side wire range 2 0 to 14 AWG Copper Aluminum Load side wire range 6 to 14 AWG Copper Aluminum FD9 332 01 4100 4100U 4100ES POWER SUPPLY close Nippled Cabinet Power Module see section for connections 4081 9306 9308 BATTERY CABINET or Internal Batteries BLACK 3 Wiring Fire Alarm System Installation Guide 574 848 External Battery Charger Installation Instructions 579 268 additional wiring instructions refer to the next section and the following publications XPS and XNAC Installation Instructions 574 772 Remote Battery Cabinet Installation Instruction 574 670 Close Nippled Power Modules Close Power section describes the required battery wiring between multiple close nippled cabinets when transponder interface cards TICs are used This is necessary to interconnect 0 V references close nippled cabinets 4 illustrates this situation Observe polarity when wiring blocks from cabinet to as shown in Figure 3 Jumper Detect Disabled 2 3 Note below Jumper Detect Enabled Pins 1 2 Note below C B A 2 3 2 3 Harness 734 023 tie PDM to Battery Terminal the PDM from 734 015 red lead to side of block black lead to side of close nippled cabinet not have batteries both red and from adjacent Wiring is in the field adjacent close cabinet does batteries route black from cabinet This 0V reference the cabinet Wiring supplied in the field the PDM from 734 015 red lead to side of block Tie lead to side of 4 Wiring Batteries between Close Nippled Cabinets No TICs Used the example shown in Figure 4 the power supply in Cabinet B receives battery backup from the set in Cabinet A Battery power passes from Cabinet A to B via the red and black wires fault detection is from the SPS in Cabinet A Enable Earth Detect on the SPS by setting P7 on the SPS to position 1 2 Right See Figure 4 charger in Cabinet C is charging a separate set of batteries Only the black wire 0V is Disable the Earth Detect circuit on the RPS SPS by moving the jumper on P7 to 2 3 Left Note that for systems with 1 or more TPS units one of the TPS Earth Detect must be enabled with all others disabled See Figure 4 E

Related Files