Simplex Installation 4100-0139 Dial Up Service Modem
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-installation-4100-0139-dial-up-service-modem-9053681274.pdf |
---|---|
Type | |
Size | 828.01 KB |
Downloads |
Text Preview
Dial Up Service Modem Instructions document covers the 4100 4120 0139 Dial Up Service Modem which can be used in with the following Network Interface Cards NICs in 4100 4100U 4100ES systems or 4100 6038 Dual RS 232 2120 Modules Field Wiring Diagram for 4100 Power Limited 841 731 or Field Wiring Diagram for 4100 Non Power Limited 841 995 Fire Alarm System Installation Guide 574 848 this Publication publication discusses the following topics Page and Warnings to the Dial Up Service Modem Requirements the Modem 2005 2011 SimplexGrinnell LP All rights reserved and other information shown were current as of publication and are subject to change without notice and the Simplex logo are trademarks of Tyco International Ltd and its affiliates and are used under license E and Warnings and AND SAVE THESE INSTRUCTIONS Follow the instructions in this installation These instructions must be followed to avoid damage to this product and associated Product operation and reliability depend upon proper installation NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED Upon your Simplex product inspect the contents of the carton for shipping damage If is apparent immediately file a claim with the carrier and notify an authorized Simplex supplier HAZARD Static electricity can damage components Handle as follows yourself before opening or installing components to installation keep components wrapped in anti static material at all times HAZARD Disconnect electrical field power when making any internal adjust or repairs All repairs should be performed by a representative or authorized agent of local Simplex product supplier RULES AND REGULATIONS PART 15 This equipment has been tested and to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC These limits are designed to provide reasonable protection against harmful interference the equipment is operated in a commercial environment This equipment generates uses can radiate radio frequency energy and if not installed and used in accordance with the manual may cause harmful interference to radio communications Operation of equipment in a residential area is likely to cause harmful interference in which case the will be required to correct the interference at his own expense REACCEPTANCE TEST AFTER SOFTWARE CHANGES To ensure system operation this product must be tested in accordance with NFPA72 1999 7 after any programming operation or change in site specific software testing is required after any change addition or deletion of system components after any modification repair or adjustment to system hardware or wiring components circuits system operations or software functions known to be affected by a must be 100 tested In addition to ensure that other operations are not inadvertently at least 10 of initiating devices that are not directly affected by the change up to a of 50 devices must also be tested and proper system operation verified TYPE PORT NETWORK CARD J1 used when configured as dial up service modem to the Dial Up Service Modem 4100 4120 0139 Dial Up Service Modem allows field personnel to access the 4100 4100U or 4120 from a remote location using the public switched telephone system or a private telephone system 1 below is an illustration of the dial up service modem Part No 565 279 No 566 338 looks identical PORT LEDs LED1 LED2 1 The Dial Up Service Modem Media Card 565 279 or 566 338 Indications dial up service modem has the following LEDs Illuminates when the modem goes off hook to connect to the transmission lines Illuminates when the modem receives an external call during dial up mode F 0 C and 120 F 49 C F 32 C 93 relative humidity non condensing Requirements section describes the software and hardware requirements that must be adhered to before the modem use the dial up service modem the following requirements must be met The Programmer software must be at Version 7.02 or later The remote IBM compatible PC must have a modem configured as follows data bits no parity 1 stop bit Hayes AT Command Set Dial up string ATDT panel phone number CR VT220 or greater Terminal Emulation After completing the connection run the string Refer to Tech Services web site or Publisher Essential program on the PC to emulate a full 4100 CRT interface For instructions for SmarTerm Essential refer to the Tech Services website or Publisher Media Settings are two jumpers on the modem 565 279 or 566 338 that need to be configured correctly and P5 a jumper on pins 1 and 2 of P4 and on pins 2 and 3 of P5 Use Figure 2 to locate the 2 Jumper Locations the Modem to the NIC dial up service modem installs onto a 4100 4120 6014 Network Interface Card NIC or a or 4100 6038 Dual RS 232 2120 Module This section describes how to install modem to both types of modules modem can be installed to the lower mid section of a 4100 4120 6014 NIC as described Use the three plastic stand offs to snap the modem into place Note that the modem will right side up unlike the media card s for the NIC port 1 and or port 2 Connect one end of the 733 808 Ribbon Cable supplied to P1 of the modem Connect other end to P1 the 10 pin service port on the NIC card Connect standard TELCO cable to P2 on the modem CARDS CARD FIT INTO HOLES PORT P1 CONNECTOR P1 SERVICE TELCO RJ 11 P2 CABLE RIBBON CABLE on next page 3 NIC Modem Installation the Modem Continued to an Module modem can be installed to the lower mid section of a 4100 4120 0113 or 4100 6038 Dual Module as described below With the modem right side up over the RS 232 daughter card align the modem three stand offs with the holes in the daughter card Connect one end of the 733 808 Ribbon Cable supplied to P1 of the modem Connect other end to P4 the 10 pin service port on the RS 232 card Connect standard TELCO cable to P2 on the modem PORT P4 FIT INTO HOLES CONNECTOR P1 SERVICE 4 RS 232 Modem Installation E