Simplex Installation Instruction TFX Fire Fighter Phone System

File Preview
File Preview
Click below to download for free

Text Preview

Introduction to TFX Fire Fighter Phone Installation Instructions publication describes the installation procedure for the 4100U 4100ES to TFX Fire Fighter card used to generate TFX phone risers Verify FACP System Programmer Executive and Slave Software when installing or replacing system components Refer to Technical Support Information and Downloads website for information this Publication publication discusses the following topics Page Warnings and Regulatory Information to the 4100U 4100ES to TFX Fire Fighter Phone the Phone Card onto the PDI Configuration Wiring 2007 2011 SimplexGrinnell LP All rights reserved and other information shown were current as of publication and are subject to change without notice and the Simplex logo and AUTOCALL are trademarks of Tyco International Ltd and its affiliates and are used under license C Warnings and Regulatory Information and AND SAVE THESE INSTRUCTIONS Follow the instructions in this installation These instructions must be followed to avoid damage to this product and associated Product operation and reliability depend upon proper installation NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED Upon your Simplex product inspect the contents of the carton for shipping damage If is apparent immediately file a claim with the carrier and notify an authorized product supplier HAZARD Disconnect electrical field power when making any internal adjust or repairs All repairs should be performed by a representative or authorized agent of local Simplex product supplier HAZARD Static electricity can damage components Handle as follows yourself before opening or installing components to installation keep components wrapped in anti static material at all times SAFETY HAZARD Under certain fiber optic application conditions the optical output this device may exceed eye safety limits Do not use magnification such as a microscope other focusing equipment when viewing the output of this device RULES AND REGULATIONS PART 15 This equipment has been tested and found to with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules limits are designed to provide reasonable protection against harmful interference when equipment is operated in a commercial environment This equipment generates uses and radiate radio frequency energy and if not installed and used in accordance with the manual may cause harmful interference to radio communications Operation of equipment in a residential area is likely to cause harmful interference in which case the will be required to correct the interference at his own expense REACCEPTANCE TEST AFTER SOFTWARE CHANGES To ensure proper system this product must be tested in accordance with NFPA 72 after any programming or change in site specific software Reacceptance testing is required after any addition or deletion of system components or after any modification repair or to system hardware or wiring components circuits system operations or software functions known to be affected by a must be 100 tested In addition to ensure that other operations are not affected at least 10 of initiating devices that are not directly affected by the up to a maximum of 50 devices must also be tested and proper system operation 72 is a registered trademark of the National Fire Protection Association Introduction to the 4100U 4100ES to TFX Fire Fighter Phone System 4100U 4100ES to AUTOCALL TFX Fire Fighter Phone System enables two way voice between the 4100 master phone station and up to 30 ATM 500 firefighter phone including up to 6 phones actively talking It is designed to be used as part of the of an installed TFX system to a 4100U 4100ES system phones on the Fire Fighter Phone System use a common communication system called a talk When the master phone the phone that actually determines whether the talk line is active is its handset is always connected to the talk line via the phone controller card Zonal phones are connected to the talk line through the ATM 500 Once a phone circuit connected to a talk line all remote phones on that circuit are also connected All active phones the talk line can talk together as on a party line The talk line is generated by the phone system card TFX Phone Card one is included as part of 4100 1298 Remote Master Telephone 4100 1281 or 4100 1287 LED Switch Cards Fire Fighter Phone System is comprised of several 4100U 4100ES modules A single system made up of one 4100 1298 Master Telephone with Phone Card plus any number of the Existing ATM 500 and Zonal phones of TFX system migrating to 4100U 4100ES item is described in detail on the following pages on next page to the 4100U 4100ES to TFX Fire Fighter Phone System Phone Illustration 1 is an illustration of the 4100 1297 phone card FD9 862 02 CIRCUIT TB1 SWITCH SW1 CONNECTOR on reverse 1 5 IN IN CIRCUIT TB1 A P1 JUMPER PHONE P3 FIREFIGHTERS PHONE CARD 1 Phone Card on next page to the 4100U 4100ES to TFX Fire Fighter Phone System Master with Phone Card Master with Phone Card Card Cards master telephone controls the talk line When a call comes in from a remote Zonal phone master phone must be picked up for the talk line to be activated and for any other remote phones in the network to listen in on the talk line phone controller gives the master telephone or the remote master phone this capability In to supplying the talk line via its connection to the master phone the controller supplies system power It also includes the following ports output connection to the audio system Class B phone circuits on the phone controller are the same as those on the remote controller and expansion cards PH1 Illuminates to indicate that riser circuit 1 is either active or is in a trouble PH2 Illuminates to indicate that riser circuit 2 is either active or is in a trouble PH3 Illuminates to indicate that riser circuit 3 is either active or is in a trouble COMM TBL Illuminates to indicate a communication failure or general card XMFR Illuminates to indicate that the network transformer is connected to a circuit cards are used if additional phone circuits are needed within a phone system beyond the phone circuits provided by the phone controller card The master controller includes one LED switch cards are used with the master phone assembly The cards LEDs and switches up a user interface from which a phone system can be controlled Switches can be used to piezos and to toggle connections to audio and phones More than one set of LED switch can be used per phone system for example one at the master controller and another at a master controller Although master phones and remote master phones are usually located the same cabinet as the LED switch cards this is not required Refer to the LED Switch Module Instructions 574 843 and the Audio Operator Interface Installation Instructions for detailed installation instructions on next page to the 4100U 4100ES to TFX Fire Fighter Phone System Phone into phone To Option 2 CommFone 500 Remote Zonal Phone Handsets FD9 862 03 3 CommFone 500 cabinet with ATM 500 to the 4100U 4100ES to TFX Fire Fighter Phone System Limitations to Table 1 for electrical environmental requirements

Related Files