Simplex Installation Instructions 1291 Remote Unit Interface
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-installation-instructions-1291-remote-unit-interface-4386791052.pdf |
---|---|
Type | |
Size | 1.51 MB |
Downloads |
Text Preview
4100 0304 1291 Unit Interface Instructions publication describes the installation procedure for the 4100 0304 1291 Remote Unit RUI card Contents Shipment unpacking your Simplex product inspect the contents of the carton for shipping damage If is apparent immediately file a claim with the carrier and notify Simplex Field Wiring Diagram for 4100 Power Limited 841 731 or Field Wiring Diagram for 4100 Non Power Limited 841 995 Fire Alarm System Installation Guide 574 848 this Publication publication discusses the following topics Page and Warnings to the RUI Card the Card Motherboards into 2975 91xx Back Boxes 4100 Motherboards into 2975 94xx Back Boxes the Daughter Card 2001 2011 SimplexGrinnell LP All rights reserved and other information shown were current as of publication and are subject to change without notice and the Simplex logo are trademarks of Tyco International Ltd and its affiliates and are used under license B and Warnings and AND SAVE THESE INSTRUCTIONS Follow the instructions in this installation These instructions must be followed to avoid damage to this product and associated Product operation and reliability depend upon proper installation NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED Upon your Simplex product inspect the contents of the carton for shipping damage If is apparent immediately file a claim with the carrier and notify an authorized product supplier HAZARD Disconnect electrical field power when making any internal adjust or repairs All repairs should be performed by a representative or authorized agent of local Simplex product supplier HAZARD Static electricity can damage components Handle as follows yourself before opening or installing components to installation keep components wrapped in anti static material at all times SAFETY HAZARD Under certain fiber optic application conditions the optical output this device may exceed eye safety limits Do not use magnification such as a microscope other focusing equipment when viewing the output of this device RULES AND REGULATIONS PART 15 This equipment has been tested and found to with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules limits are designed to provide reasonable protection against harmful interference when equipment is operated in a commercial environment This equipment generates uses and radiate radio frequency energy and if not installed and used in accordance with the manual may cause harmful interference to radio communications Operation of equipment in a residential area is likely to cause harmful interference in which case the will be required to correct the interference at his own expense REACCEPTANCE TEST AFTER SOFTWARE CHANGES To ensure proper system this product must be tested in accordance with NFPA 72 after any programming or change in site specific software Reacceptance testing is required after any addition or deletion of system components or after any modification repair or to system hardware or wiring components circuits system operations or software functions known to be affected by a must be 100 tested In addition to ensure that other operations are not affected at least 10 of initiating devices that are not directly affected by the up to a maximum of 50 devices must also be tested and proper system operation 72 is a registered trademark of the National Fire Protection Association to the RUI Card RUI card is used in MINIPLEX systems to extend the length of communications wire to reach bays 1 below is an illustration of the RUI card 1 The Remote Unit Interface Card RUI card mounts onto a 562 799 or 562 856 Motherboard 1 lights when there is a Slave trouble from a connected MINIPLEX Transponder 2 lights when there is a Class A trouble on the communications line 3 lights when there is a XMIT short trouble Class A w o RIC II remote or Class B on steady until short is removed Class A w RIC II remote or Style 7 on only if short is between RUI and the first RIC II 4 lights when there is a Class A XMIT short trouble Class A w o RIC II remote or Class B on steady until short is removed Class A w RIC II remote or Style 7 on only if short is between RUI and the first RIC II to Table 1 for electrical and environmental requirements 1 Specifications Rate Selectable VDC 170 mA 2400 4800 to 120 F 0 to 50 C to 85 Non condensing the Card SW1 on the is a bank of eight dip switches From left to right see Figure 2 below these are designated as SW1 1 through SW1 8 The function of these switches is as follows SW1 1 This switch sets the baud rate for the internal 4100 communications line running the card and the 4100 CPU Set this switch to ON SW1 2 through SW1 8 These switches set the card address within the 4100 FACP to Table 5 for a complete list of the switch settings for all of the possible card addresses You must set these switches to the value assigned to the card by the Comm Baud Rate SW2 1 Be Set to ON Switches SW1 2 through set the Card Address shows an Address of 3 2 DIP Switch SW1 on next page the Card Continued 2 Card Addresses 2 2 2 3 2 4 2 5 2 6 2 7 2 2 2 7 2 8