Simplex Installation Instructions 4100-3115 XALIC
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-installation-instructions-4100-3115-xalic-2683071549.pdf |
---|---|
Type | |
Size | 877.16 KB |
Downloads |
Text Preview
Introduction XALIC and Programming Guide publication describes installing and programming the 4100 3115 XA Loop Interface Card This card allows a 4100U or a 4100ES Fire Alarm Control Panel FACP to function as the XA Loop Master or as an XA Loop Slave card is compatible with a 4100U FACP or a 4100ES FACP this Publication publication discusses the following topics Page and Warnings and Specifications Configuration Installation to the XA Loop the FACP as XA Loop Master FACP as an XA Loop Slave XA Loop Slave Application Example XA Loop Master Application Example 2005 2011 SimplexGrinnell LP All rights reserved and other information shown were current as of publication and are subject to change without notice and the Simplex logo are trademarks of Tyco International Ltd and its affiliates and are used under license D and Warnings and AND SAVE THESE INSTRUCTIONS Follow the instructions in this installation These instructions must be followed to avoid damage to this product and associated Product operation and reliability depend upon proper installation NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED Upon your Simplex product inspect the contents of the carton for shipping damage If is apparent immediately file a claim with the carrier and notify an authorized product supplier HAZARD Disconnect electrical field power when making any internal adjust or repairs All repairs should be performed by a representative or authorized agent of local Simplex product supplier SAFETY HAZARD Under certain fiber optic application conditions the optical output this device may exceed eye safety limits Do not use magnification such as a microscope other focusing equipment when viewing the output of this device HAZARD Static electricity can damage components Handle as follows yourself before opening or installing components to installation keep components wrapped in anti static material at all times RULES AND REGULATIONS PART 15 This equipment has been tested and found to with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules limits are designed to provide reasonable protection against harmful interference when equipment is operated in a commercial environment This equipment generates uses and radiate radio frequency energy and if not installed and used in accordance with the manual may cause harmful interference to radio communications Operation of equipment in a residential area is likely to cause harmful interference in which case the will be required to correct the interference at his own expense REACCEPTANCE TEST AFTER SOFTWARE CHANGES To ensure system operation this product must be tested in accordance with NFPA 72 after any operation or change in site specific software Reacceptance testing is required any change addition or deletion of system components or after any modification repair adjustment to system hardware or wiring components circuits system operations or software functions known to be affected by a must be 100 tested In addition to ensure that other operations are not affected at least 10 of initiating devices that are not directly affected by the up to a maximum of 50 devices must also be tested and proper system operation 72 is a registered trademark of the National Fire Protection Association and Specifications XA loop is a three or four wire Autocall communication channel consisting of one master one or more slaves The XA Loop Interface Card XALIC connects the FACP to the XA and allows the FACP to function as either the XA loop master or as an XA loop slave FACP XA Loop Master In this case the FACP replaces an existing Autocall head end operating as the XA loop master the FACP can issue ON OFF control commands to devices and monitor the alarm trouble and normal status of all XA devices on the loop FACP XA Loop Slave Devices attached to the FACP can be either of the following XALIC Status Points Custom control is used to pass the FACP point status changes to Autocall head end via the XA devices represented by the XALIC XALIC Control Points This type of point works in a similar manner Custom control on FACP monitors the state of the XALIC points and performs specific functions signal alarm reset etc when the Autocall head end turns a specific XALIC point on or Components XALIC card shown in Figure 1 contains the following major components Blocks and Switches 1 XALIC Components connects the XALIC to the XA loop 18 position terminal block consists of two separate of terminals one for master operation and one for slave operation PDI Connector a 10 pin connector located on the reverse side of the PCB Used for to the FACP Power Distribution Interface PDI RUI Connector a 3 position terminal block used for connecting Style 4 RUI AUX Power Connection used for connecting the XALIC to an auxiliary power supply and P2 Power Source Jumpers select the power source System Power Supply or Power Supply used by the XALIC Earth Detect Jumper used to connect disconnect the Earth detect circuitry sets XA loop options 3 or 4 wire loop scan rate master slave operation Address Dip Switch configures the FACP address used by the XALIC card Address via dipswitch must match address programmed via the FACP programmer 1 XA Loop Status OFF Normal Steady ON XA Loop Channel Failure Single Blink XA Loop Wiring Fault 2 4100 Communication Status OFF indicates the card is communication normally indicates a trouble condition with the communication channel between the and the FACP 3 Supervision Flashes once every XA loop polling cycle XA loop master only on next page and Specifications Continued Components Loop Field Wiring Block TB3 A B SHLD REF SIG CMD CLK A SIG A CMD A CLK A SHLD REF B SIG B CMD B CLK B Loop Polling LED3 Loop SW1 Detect Jumper Switch SW2 OFF 3 WIRE SLAVE MASTER 256 257 ON 9600 Trouble LED Loop Trouble LED1 Connector P4 reverse side Source Jumpers default position 1 2 Style 4 TB1 Power Connection RIGHT FOR POWER LEFT FOR POWER 1 Location of Major XALIC Components on next page and Specifications Continued 2 Specifications Line Card Draw XA Master Draw XA Slave mA 24 VDC maximum mA 24 VDC Resistance Capacitance 24 VDC from FACP When power is through the AUX and AUX the power must be provided by a supply that is UL listed for fire protective use per wire wire to wire wire to shield Loop Supervision Alarm mA mA Number of per Loop 255 VAC 250 Hz C 32 F to 49 C 120 F inclusive to 93 relative humidity non condensing 32 C 90 F Configuration DIP Switch XALIC Card XALIC card address is set via DIP switch SW2 which is a bank of eight switches From left right see Figure 2 below these switches are designated as SW2 1 through SW2 8 The of these switches is as follows SW2 1 This switch sets the baud rate for the internal FACP communications line between the card and the FACP CPU Set this switch to ON SW2 2 through SW2 8 These switches set the card address Refer to Table 3 for a list of the