Cautions and Tamper Switch Instructions AND SAVE THESE INSTRUCTIONS Follow the instructions in this installation manual instructions must be followed to avoid damage to this product and associated equipment Product and reliability depend upon proper installation NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED Upon unpacking Simplex product inspect the contents of the carton for shipping damage If damage is apparent file a claim with the carrier and notify an authorized Simplex product supplier HAZARD Disconnect electrical field power when making any internal adjustments or All repairs should be performed by a representative or authorized agent of your local Simplex supplier HAZARD Static electricity can damage components Handle as follows Ground yourself before opening or installing components Prior to installation keep components wrapped in anti static material at all times RULES AND REGULATIONS PART 15 This equipment has been tested and found to com with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are to provide reasonable protection against harmful interference when the equipment is operated in commercial environment This equipment generates uses and can radiate radio frequency energy and not installed and used in accordance with the instruction manual may cause harmful interference to communications Operation of this equipment in a residential area is likely to cause harmful interfer in which case the user will be required to correct the interference at his own expense publication describes the installation procedure for the 4100 6034 Tamper Switch with Individual Adapter Module IAM Product is compatible with both 4100U and 4100ES Fire Alarm Control Panels FACP this publication discuses the following topics Procedure Procedure tamper switch see Figure 1 is used to monitor either the solid door or the dress panel of the alarm control panel The tamper switch does not monitor the glass door it only monitors the panel that is associated with the glass door An IDNet IAM is mounted to the bracket It is to the contact of the tamper switch and added to the system via the FACP programmer of the switch by the IAM is programmable as either a Trouble or as a Priority 2 Alarm program the IAM set the device type as IAM then select the point type as either TROUBLE as GENPRI2 When servicing the panel the tamper switch may be disabled by pulling the plastic plunger out until it locks into place the door or dress panel must remain open for the to be maintained in this position 2006 2011 SimplexGrinnell LP All rights reserved and other information shown were current as of publication and are subject to change without notice and the Simplex logo are trademarks of Tyco International Ltd and its affiliates and are used under license E Switch Note which way the solid door on your FACP will open and prepare to install the tamper switch if the door swings towards the left then the tamper switch must mount to the right the back box and vice versa Match up the appropriate two mounting holes on the tamper switch to the two screw studs about up on the inside of the cabinet if you are mounting to a back box with glass doors and panels use the top front mounting holes see Figure 1 If you are mounting to a back box solid doors and no dress panel use the top back mounting holes The bottom mounting holes are used to mount the switch on the other side of the cabinet Set the tamper switch on the screw studs and fasten the tamper switch to the back box with the number six flange nuts provided holes holes wiring to or to IDNET mounting holes 1 Tamper Switch to Figure 2 and the notes for wiring instructions Note 1 4100 System Power Board B B Inputs IDNET Card B B IAM Assembly Switch 2 Tamper Switch with IDNET IAM 2 Notes Field installed wires maintain polarity and use 12 to 18 AWG wire from supervised IAM assembly system power supply IAM assembly Tamper switch harness and 6.8K resistor are factory connected to locations 3 and 4 on the W E

Related Files