Simplex Installation Instructions TFX Voltage Regulator Module

File Preview
File Preview
Click below to download for free

Text Preview

4100 5130 Voltage Regulator Module Instructions AND SAVE THESE INSTRUCTIONS Follow the instructions in this installation manual These instructions must be to avoid damage to this product and associated equipment Product operation and reliability depend upon proper NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS DAMAGED Upon unpacking your Simplex product the contents of the carton for shipping damage If damage is apparent immediately file a claim with the carrier and notify authorized Simplex product supplier HAZARD Disconnect electrical field power when making any internal adjustments or repairs All repairs should performed by a representative or authorized agent of your local Simplex product supplier HAZARD Static electricity can damage components Handle as follows Ground yourself before opening or installing components Prior to installation keep components wrapped in anti static material at all times RULES AND REGULATIONS PART 15 This equipment has been tested and found to comply with the limits for a Class A digital pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a res area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense REACCEPTANCE TEST AFTER SOFTWARE CHANGES To ensure proper system operation this product must be tested in with NFPA 72 after any programming operation or change in site specific software Reacceptance testing is required after any change or deletion of system components or after any modification repair or adjustment to system hardware or wiring components circuits system operations or software functions known to be affected by a change must be 100 tested In addition to ensure that operations are not inadvertently affected at least 10 of initiating devices that are not directly affected by the change up to a maximum of 50 must also be tested and proper system operation verified 4100 5130 TFX Voltage Regulator module provides a regulated output that is compatible with power supply 24V outputs used in AUTOCALL TFX systems The regulated output is to power devices on the TFX loop that require 24V power The Voltage Regulator module used in with the TFX Loop card provides the means to replace TFX 500 and 800 series control panels a 4100U or 4100ES while retaining the existing loop wiring and devices publication covers the installation procedure of the TFX Voltage Regulator module into a 4100U or Master control panel 2007 2011 SimplexGrinnell LP All rights reserved and other information shown were current as of publication and are subject to change without notice the Simplex logo and AUTOCALL are trademarks of Tyco International Ltd and its affiliates and are used under license C this publication discusses the following topics Page to the TFX Voltage Regulator Module the Voltage Regulator Module following terms are defined addressable devices Power Distribution Interface TFX 500 and TFX 800 series fire alarm panel to the TFX Voltage Regulator Module TFX Voltage Regulator Modules regulate panel power supply output to a 25 VDC compatible with existing AUTOCALL TFX RPS424 and PSM800 power supplies Power is from the signal power circuit of the panel PDI bus and is considered auxiliary for panel power calculations 25 VDC regulated output is isolated from the Panel and complies with power limited Operation is resettable allowing use with addressable loop modules that interface conventional detectors card is a flat 4 x5 form factor module that plugs into the Panel power distribution interface 1 TFX Voltage Regulator module on next page to the TFX Voltage Regulator Module Continued TFX Voltage Regulator module has the following status indicating LEDs refer to Figure 1 for location 1 Status Indicating LEDs Name when 25V Output is on On Trouble Earth Trouble if for resistance to 25C Earth Trouble if for resistance to 25V Active during reset tracks reset input if Short circuit Overcurrent protection active Yellow Detect Voltage Regulator card has an isolated earth detect circuit Sensitivity is 10K ohms to earth trouble is indicated on card via trouble LEDs see Table 1 Because the Voltage Regulator doesn communicate with the Panel an earth trouble is reported by causing a negative fault on the non isolated side of the Panel for detection by the SPS It will also cause the relay to change state for monitoring by an IAM or similar device Relay Relay Output The trouble relay provides a C dry contact for monitoring by an or similar device The trouble relay will change state for earth trouble or 25V output troubles contact is rated at 400mA 30VDC resistive The common trouble relay is normally energized 24VDC Supervisory Current 3.00A maximum with 2.5A load on output Alarm Current 4.90A maximum with 4.0A load on output Input power comes from the Signal Power connection on the PDI This power is as AUX power for battery standby calculations An XPS 4100 5101 5102 SPS 4100 5111 5112 5113 or RPS 4100 5125 5126 5127 is to provide signal power on next page to the TFX Voltage Regulator Module Continued 25VDC Regulated Ripple 600 mVp p Current Rating 2.5A Maximum 4.0A Maximum Output is resetable will track state of RESET input Output is supervised and power limited Wire size 12 18 AWG 3.31 0.82 mm2 Operating Temperature 32 to 120F 0 to 49C Humidity Up to 93 relative humidity at 90F 32C the Voltage Regulator Module Wiring 2 Field Wiring Connections Block Used normally open contact Trouble relay center contact Trouble relay normally closed Trouble relay 2 Voltage Regulator Module Field Wiring the Voltage Regulator Module Continued TFX Voltage Regulator module mounts on a PDI in a Panel expansion box It can be mounted any available block Refer to Figure 3 3 TFX Voltage Regulator Module Installation

Related Files