Simplex iSecure FireWatch
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-isecure-firewatch-2459713608.pdf |
---|---|
Type | |
Size | 739.44 KB |
Downloads |
Text Preview
Pro can act as secondary fire station Single point source for Access Control and Fire Monitoring Historical Event Archiving Event Printing Report Generation Ability to route fire alarms to any location on the Path network Output points can be activated by fire alarm Control of iSecure Vision components based on fire conditions with optional iSecure Vision module iSecure FireWatch option for the iSecure Pro Security Management ISM System provides unique interface to the Simplex iSecure Path network the iSecure Pro to receive annunciate log print control fire alarm events Each fire event can be in the iSecure Pro system with an alarm and a priority level The fire event can then be on the iSecure Workstations and treated in the or a unique manner as other alarm conditions generated from iSecure Path network events can presented as break through alarms displayed on the iSecure Maps module from the iSecure Path network that are configured cause an alarm condition can be acknowledged from an Workstation Configured fire alarm points do not the overall input point capacity of the iSecure system Annunciation status changes on 4120 points operate the same as any Access Control point They may be sent to the selected workstations or specific operators iSecure Pro ISM can be configured to produce an condition based on any status change or event by the iSecure Path network Events are generated messages caused by either a physical change or a software point change The iSecure Pro generated by iSecure Path network events can be to occur only during certain times of the day FireWatch 3700 7008 part of the alarm definition the iSecure Pro can be to route or forward the fire events or alarms to single destination or multiple destinations Available include specific workstations operators printers An operator is different than a workstation that all assigned messages follow the operator no where the operator is logged on within the iSecure network The operator may receive an alarm on a in building one the first week then on a workstation in a different building the next If routed to a workstation the event or alarm is annunciated at that specific computer alarm generated within the iSecure ISM can be 1 of 99 Alarm Priority Levels with unique colors assist in expediting the alarm handling process In each alarm can be assigned a unique custom message ensuring the operator is aware of the actions required when the alarm is displayed which are of extreme importance can be to automatically interrupt the computer being conducted and display the relevant alarm These alarms can also be on the optional iSecure Maps module and using a priority range Whenever an alarm that priority or higher is received it is immediately to the primary screen of the workstation monitor Alarm Generation the iSecure Pro system is configured with the FireWatch module all points being imported the Fire Alarm System will be automatically placed one or more of four groups in the iSecure system based the point type Priority 1 Fire Priority 2 Security Supervisory Trouble Operation default iSecure alarms on points mapped from the Alarm System operate synchronously with the fire and can acknowledged from either the iSecure Pro the fire system an alarm generated by an iSecure Path network is acknowledged in the Access Control system an request is sent to the Fire Alarm System Acknowledge request causes the alarm point to from the alarm state to the Acknowledge state is subsequently sent from the Fire Alarm System back the iSecure Pro When this Acknowledge state change received by the iSecure Pro system it acknowledges the 02 02 are two options for the Acknowledge operation are Code compliant acknowledgement UL Listed Acknowledgement subject to local authority jurisdiction and owner acceptance Listed the code compliant operation the iSecure Pro silences alert and panel sounder on both the iSecure Pro and iSecure Path network In the other option the iSecure network alarm point will be acknowledged by the Pro Silence and System Reset Operation configuration of the iSecure Pro system with the FireWatch interface can include signal silence or reset operations As a result software buttons will on the iSecure Annunciator screen When a or reset button is pressed a network point request sent to the specified 4120 network point The 4120 node will then perform a signal silence or reset to all network nodes On Off Control Point Monitor and Control application which is part the iSecure Pro ISM system provides a method of a point on or off This application provides the to request on and off commands to network and pseudo points primarily used for diagnostic and to manually control a point These requests be recognized by the iSecure software as being to an external point The software will then a network request to turn the point on or off or to automatic control Capabilities iSecure FireWatch module allows a network report to be produced on the iSecure Pro system contains the status of each configured node as well as nodes not configured but which have been detected the network network topology function also provides the ability to a window similar to the 4120 for displaying message error counts with percentages Capabilities iSecure Pro ISM includes a comprehensive Report Utility that displays prints or exports to a file fire event information in an easy to read format operators can request reports from a series of templates that can then be sorted or within the template Any of the templates that are consistently being or sorted in a specific way may be saved as a template to further expedite the reporting process more information on the iSecure Pro ISM system to the S3700 0001 datasheet 02 02 Pro Workstations Path to iSecure via FireWatch Communications Pro Fire Alarm Network The iSecure Controllers ISCs must be placed on a dedicated security network ISCs can not be intermixed on the 4120 Fire Alarm Network iSecure Network Using the iSecure FireWatch Module 02 02 the Simplex logo and iSecure are either trademarks or registered trademarks of ADT Services AG a Tyco company in US and or other countries Microsoft and Windows are registered trademarks of Microsoft Corporation All other trademarks property of their respective owners Massachusetts 01441 0001 USA www simplexnet com 2002 Simplex Time Recorder Co DBA TEPG US a Tyco company All rights reserved specifications and other information shown were current as of printing and are subject to change without notice 02 02