Simplex Johnson Controls TrueAlert Text Messaging Appliance
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-johnson-controls-truealert-text-messaging-appliance-2743069518.pdf |
---|---|
Type | |
Size | 1.13 MB |
Downloads |
Text Preview
ULC CSFM Listed TrueAlert Text Messaging Appliance Text Messaging Appliance with Addressable Selection using IDNet Communications Text Messaging Appliance Illustration with Sample Message visibility multi color LED text message provides visible textual alarm notification from compatible Johnson Controls fire control panels During alarm conditions up to 32 pre programmed selections can be activated in response to emergency situations or linked to specific point status conditions Text messages provide textual alarm notification for of high noise or with other audibility limitations Text messages can duplicate a broadcasted audible or can provide more local detail per the Communication Systems Mass Notification UL listed to Standard 1638 Textual Visible Appliance listed to S527 Miscellaneous Ancillary Device to ULC message note requirement on page 3 with the 4007ES 4010 4010ES and 4100U Series fire alarm control panel IDNet communications communications format emulates 4009 IDNet Extender 4009A controls for easy interfacing 4007ES 4010ES 4100ES and 4100U IDNet SLCs line circuit can control up to 25 message with up to ten 10 4009 IDNet NAC Extenders 4010 IDNet SLCs control up to five 5 total of either type message presentation area provides long wide area 140 viewing Dual line 2.3 58 mm high messages provide typical distance of up to 100 ft 30.5 m Single line 4.7 119 mm high messages provide viewing distance of up to 200 ft 61 m LEDs are multi color red yellow green to emphasize content Words can be upper or lower case standard bolded or expanded with selectable sizes Messages can be static flashing or scrolling with a of appearance transition options communications control provides Up to 32 available messages 10 factory messages are included message details Advise of proper evacuation routes relocate to a secure take action due to severe weather conditions in place or other facility specific actions New messages can be created factory pre programmed can be modified if needed Please note that the creation and modification of alarm may trigger code mandated retesting of the alarm system and should be performed by authorized personnel non alarm general messages can be using TrueSite Workstation Free Form Software requirements Message board is powered by listed fire alarm power providing 24 VDC with battery backup typically by host control panel features Standard message board includes fixed brackets for wall and also includes 100 mm VESA Video Standards Association mounting holes for with listed wall or ceiling VESA mounting bracket Optional wall mount adjustable brackets allow rotation where required for improved viewing Optional mounting box secures to wall surface or can also mount with 100 mm VESA bracket Ceiling mounting is available by cable suspension to top mounted eyehooks optional operation mode Message boards can also display general non alarm via local LAN Ethernet connection created TrueSite Workstation Free Form Messaging general free form messaging is overridden an Alarm or Alert condition Control panels will override non alarm messages upon they can also be programmed to blank the display local power failure to conserve batteries This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of California Health and Safety Code See CSFM Listing 7300 0026 324 for allowable values and or concerning material presented in this document It is subject to re examination revision and cancellation Additional listings may be applicable contact your local Johnson Controls product for the latest status Listings and approvals under Simplex Time Recorder Co are the property of Controls International 10 2019 Messaging Appliances Audible appliances and are commonly used to provide notification of alarm typically to signal the need for building However when the required response is to defend in place or provide detailed information Text Messaging Appliances display custom text with the instructions required per the local communication systems mass notification plan Mode When alarm conditions occur the fire alarm overrides optional non alarm messaging and selects programmed messages pre determined to be appropriate the reported conditions In multiple alarm situations up 8 messages can be displayed in sequence and Date Optional If desired the TrueAlert Appliance can be configured to display time date obtained from an SNTP server on the facility network Messaging Optional Fire detection configured with a TrueSite Work Station TSW capable of sending custom free form messages of up 100 characters to 4907 9007 displays that are on the Ethernet network Free form messaging is a discrete that operates on TSWs equipped with Windows 7 and Windows 10 operating Alarm messages will always take priority over free form general messages being displayed that were not factory configured with the free messaging application can be upgraded by the software from the appropriate JCI Communications Optional The TrueAlert Messaging Appliance can receive messages from cloud based emergency platforms such as e2campus or Rave Mobile Using these services the sign queries the notification platform for messages These notification service platforms provide a web that enable a local authority such as a chief of for example to log in on their PC and send messages to a portal for transmission to various types including the 4907 9007 display Note that customer must have an account with an emergency service to employ this capability Monitoring Optional Authorized users can the configuration and operating status of 4907 9007 from a web browser by accessing using the support account is included with each message board Remote can be configured to allow email alerts to be in the rare event that one or more 4907 9007 lose time synchronization or becomes non Failure Mode The host fire alarm panel can be such that during a local power failure the message is sent to reduce battery standby In the event of an alarm condition during failure the panel will use its battery backup to power the appliance and display the appropriate Control Process The compatible fire alarm panel activates the Messaging Appliances by IDNet communications commands similar to used to control the 4009 IDNet NAC Extender include control of up to 8 NACs and with NAC capable of up to 4 different control modes in a total of 32 commands available to select messages and or the blanking control 10 2019 Product Selection Messaging Appliance in dark gray housing supplied with fixed mounting brackets for wall mounting holes for VESA bracket mounting or for ceiling cable mounting Adjustable Swivel Mount Brackets 2 to allow wall mounted appliance to be tilted down where desired Ethernet Cable 15 ft long 4.6 m connect for non fire alarm messaging input Mounting Box lightweight aluminum painted dark gray 30 5 16 W x 6 3 4 H x 1 3 8 D shipped with for attaching messaging appliance refer to details on page 4 Factory Pre Programmed Messages sec sec Message top line is yellow bottom is scrolling red except as noted Line Fixed Bomb Threat Line Scroll emergency has been reported in the building Please proceed to the nearest and vacate the building Lin