Simplex LifeAlarm Fire Alarm Controls; Emergency Voice Communications Equipment, 4003EC Voice Control Panels (and related accessory products)

File Preview
File Preview
Click below to download for free

Text Preview

Datasheet Fire Alarm Controls Communication Systems and Mass Notification Systems 4003EC Voice Control Approved to ANSI UL 864 Control Accessory to FM Standards Listed 4003EC Voice Control Unit adds digital voice message capability to fire alarm control units Remote booster amplifiers are available to expand coverage area or to multiple notification areas Activate up to 8 separate messages by direct connection to fire control unit FACU NACs using the NAC Interface Module or by a supervised connection to relay contact closures 4003EC voice control unit status alarm system trouble or separate trouble is through isolated contact closure allowing compatibility a wide range of Simplex brand and other fire alarm systems Multiple 4003EC control units can interconnect for system wide Communication Systems ECS Mass Notification Systems message control using Simplex fire alarm network node Broadcast live messages using the internal microphone or up to 18 microphones Select from 8 digitally pre recorded messages using the control switches or controlled from the FACU select a pre tone and a post tone if desired You can order custom messages separately as custom chip sets record directly at the unit requires external equipment new override standard messages control unit details Efficient Class D amplifier design provides 40 W at 25 VRMS or 70.7 with power limited output One general alarm Class B audio NAC rated at 40 W can be expanded to four Class B NACs or two Class A NACs using a A B Splitter One general alarm Class B 2 A strobe NAC with strobe formatted to synchronize either Simplex or Cooper Wheelock strobes not mixed Internal push to talk microphone and individual manual tone or controls for convenient operator control Strobe circuit activation is DIP switch selectable for each recorded for microphone use and for auxiliary input Multiple connections are available for auxiliary output power 24 1 2 A maximum Internal battery charger for up to 12 Ah batteries in cabinet or up to Ah batteries in a separate cabinet Removable terminal blocks for easy wiring Beige or red cabinet for surface mounting booster amplifier details Remote booster amplifiers are available with 80 W with 2 2 A circuits 160 W and 320 W each has an efficient Class D design Wiring options allow limited or detailed control with respect to power failure and non fire alarm operation modes Wiring options allow control of non alarm audio output when on standby and selection of monitoring main trouble contacts or trouble contacts 1 4003EC Voice Control Unit Removable terminal blocks for easy wiring Beige or red cabinet for surface mounting optional features Supervised remote microphones with key switch control beige or for alarm paging Local Operating Console LOC providing enclosed microphone and control for the 8 unit messages Application Note For control from a Wide Area Notification System audio 1 VRMS 600 ohm and contact closure wiring to an input port on a Remote Microphone Expansion Module Four circuit NAC module Class A or Class for boosters or control allows zone wiring separation Extensive non fire alarm features are available for night ringer tone telephone page input and background music Non fire alarm paging includes zone control and zone volume that are bypassed when the unit is in alarm mode Models are available for 120 VAC or 240 VAC input non voice FACUs require the addition of voice and tone Simplex 4003EC Emergency Communications Voice Control supply an extensive feature list Available equipment includes up 18 remote microphones up to 5000 W of distributed remote booster and extensive non fire alarm general paging controls operation requires opening the locked 4003EC cabinet door access the 8 message selection switches the local microphone and status indicator LEDs Secure control of remote microphones using a switch See Figure 4 applications Add audio operations to existing fire alarm control units or non audio Use of non emergency operations is suspended during battery operation and is overridden during emergency conditions Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co S4003 0002 Rev 10 8 2021 Communication Systems and Mass Notification Systems 4003EC Voice Control Units voice control module features of pre and post audio tones can select pre message tones and if desired you can also select the same tone as a post message tone Tones are switch selected onboard and for each message pairs IN1 and IN2 message will have the same tone IN3 and IN4 message will have the same tone tones Temporal Pattern Bell a digitally recorded mechanical bell sound Temporal Pattern Horn 500 Hz tone Slow Whoop a slowly ascending tone Wail ascends then descends between 600 Hz to 940 Chime Tone Announcement Chime High Low with high frequency of 750 Hz for 100 ms and low frequency of 500 Hz for 400 GSA Tone continuous 2000 Hz Fast Whoop a quickly ascending tone Horn Tone at 120 beats per minute Horn Tone at 20 beats per minute Bell Tone at 60 beats per minute Pattern evacuation signal reference sec on 1 2 sec off 1 2 sec on 1 2 sec off 1 2 sec on 1 1 2 sec off digitally recorded messages Messages can be reproduced from high quality customer supplied audio professionally recorded to customer requirements or selected from the message library To order Custom Messages provide a CD or tape as appropriate a completed custom message questionnaire and include an English language Internal Order Processing Note Document this information using the FASTool configurator If supplied by a CD provide a WAV file format with 44,100 HZ and 16 bit mono Contact your local Simplex product representative for details Custom messages can be recorded at the control unit Locally recorded messages overwrite the pre recorded messages and external equipment is alarm operation features Addressable Paging Splitters Model 4003 9845 allow non Alarm paging to be routed to zones as desired Supervised Volume Controls Model 4003 9848 allow non Alarm paging and background music local volumes to be adjusted as desired during alarm the volume controls are bypassed This is not a Non Fire feature it was specifically developed for Fire ECS MNS Applications Telephone Zone Controller Model 4003 9835 allows phone control selection of zones for background music or paging Night ringer telephone and security alert modes allow the 4003EC unit to provide system tones alerting of non alarm conditions needing attention In night ringer mode an externally mounted switch such as a doorbell switch can allow creation of a specific tone to alert a security guard who may be in normal hearing range of the daytime doorbell sound supply battery charger features Charges up to 33 Ah batteries up to 12 Ah batteries for cabinet mounting larger batteries are housed in a separate close nippled battery cabinet Green power on LED yellow trouble LED Earth fault detection battery supervision circuitry power loss and brownout voltage supervision 2 S4003 0002 Rev 10 8 2021 Communication Systems and Mass Notification Systems 4003EC Voice Control Units messages and input priority list 1 Temporal Pattern evacuation signal reference 1 2 sec on 1 2 sec off 1 2 sec on 1 2 sec off 1 2 on 1 1 2 sec off Input type unit push to talk microphone for on site messages input from one or multiple remote microphones or from a separate audio input with voltage selectable as 1 25 VRMS or 70.7 VRMS Multiple microphones require use of 4003 9834 Microphone Expansion Modules

Related Files