Simplex Multi-Application Peripherals and Accessories, Non-Coded Manual Stations, 2099 Series Single and Double Action Operation
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-multi-application-peripherals-and-accessories-non-coded-manual-stations-2099-series-single-and-double-action-operation-8360271954.pdf |
---|---|
Type | |
Size | 1.60 MB |
Downloads |
Text Preview
Multi Application Peripherals Non Addressable Manual Stations 2099 Series Single and Double Action ULC CSFM Listed Approved MEA NYC fire alarm stations for general purpose applications Operation complies with ADA requirements Pull lever protrudes when alarmed Break rod is supplied use is optional Screw terminals for wiring connections Tamper resistant reset key lock keyed same as Simplex fire alarm types include Single action Double Action Breakglass or Push Type Institutional Model key operated only Optional NO GRIP Single Action Retrofit Kits are available with a more operated pull lever for applications where anticipated users may the standard station lever difficult to activate Optional Local Alarm cover Optional pre signal and annunciator contacts mounting options Surface or semi flush with standard boxes or matching Simplex boxes Flush mount adapter kit listed to Standard 38 of the Simplex single action manual stations requires a downward pull to activate the alarm switch Completing the action an internal plastic break rod which is visible below the pull lever is optional The use of a break rod can be a deterrent to vandalism interfering with the minimum pull requirements needed for easy The pull lever latches into the alarm position and remains out of the housing to provide a visible indication Action Stations Breakglass require the operator to strike front mounted hammer to break the glass and expose the recessed lever The pull lever then operates as a single action station Action Stations Push Type require that a spring loaded plate which is marked PUSH be pushed back to access the lever of the single action station reset requires the use of a key to reset the manual station lever deactivate the alarm switch If the break rod is used it must be testing is performed by physical activation of the pull lever testing can be also performed by unlocking the station housing activate the alarm switch 1 Station 2 Action Push Type 3 Action Breakglass 4 Fire Cover Option 5 Station with Cover 6 GRIP Retrofit kit Stations activate by key operation only allowing access manual alarms to be initiated by authorized personnel Operation key insertion and opening of the station cover Action Station NO GRIP Retrofit Kit 4099 9805 For such as California Building Code Title 24 which requires and operating mechanisms shall be operable with one hand shall not require tight grasping pinching or twisting of the wrist the 4099 9805 Retrofit kit provides a more easily operated pull lever to standard stations Option activates when the lever is pulled General alarm requires a key to activate a keyswitch located behind the pull Reset requires the use of a key to reset the manual station and deactivate the alarm switch If the break rod is used it must be requires physical activation of the pull lever except for stations These products have been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7150 0026 175 Pull Boxes 7150 0026 0224 NO GRIP Retrofit Kit for allowable values and or conditions concerning material presented in this document Additional listings may be applicable contact your local product for the latest status Listings and approvals under Time Recorder Co are the property of Tyco Fire Protection Products Rev 19 02 2021 Non Addressable Manual Stations 2099 Series Single and Double Action Operation reference to NFPA 72 the National Fire Alarm and Signaling Code and all applicable local codes for complete requirements for manual stations following summarizes the basic requirements Stations shall be located in the normal path of exit and distributed in the protected area such that they are unobstructed and readily accessible Mounting shall be with the operable part not less than 42 in 1.07 m and not more than 48 in 1.22 m above floor level At least one station shall be provided on each floor Additional stations shall be provided to obtain a travel distance not more than 200 ft 61 m the nearest station from any point in the building When manual station coverage appears limited in any way additional stations should be installed selection 1 Single action models General alarm N O N C alarm cover Institutional 2 Double action models General Alarm 3 Accessories N O N C Kit for field conversion of a single action station to a NO GRIP station reference Instructions 579 1007 breakglass standard English break rod adapter kit black refer to page 4 adapter kit beige refer to page 4 retaining clip for breakglass cover kit surface mount box sheet metal 5 3 16 in H x 4 in W x 2 3 16 in D 127 mm x 102 mm x 56 mm cast aluminum surface mount box 5 in H x 3 7 8 in W x 2 3 16 in D 127 mm x 98 mm x 56 mm key for manual station reset These models can be semi flush mounted using a standard single gang 2 1 5 in 64 mm deep switch box DO NOT RECESS BOX mount box or with 1 16 in 2 mm maximum protrusion These models can also be surface mounted on a Wiremold box model number V5744S 4 5 8 H x 2 7 8 in W x 2 1 4 in D 117 mm x 73 mm x 57 mm For surface mount these models require 2975 9178 or 2099 9022 boxes For semi flush mount these models require a 4 in 102 mm square with a single gang cover plate see diagram on page 3 2 Rev 19 02 2021 Non Addressable Manual Stations 2099 Series Single and Double Action Operation manual station reference manual sheet stations manual stations addressable guard addr non addr sheet manual stations stations for hazardous locations Ring Pull housing and explosion proof weather proof stations T Handle sheet manual stations addressable for releasing guard addr non addr sheet mounting reference Figure shows 2975 9178 box and 2975 9022 cast box 7 mounting reference 3 Rev 19 02 2021 Non Addressable Manual Stations 2099 Series Single and Double Action Operation mounting reference 8 mounting reference 4 Rev 19 02 2021 Non Addressable Manual Stations 2099 Series Single and Double Action Operation mount reference Figure shows 2099 9819 black and 2099 9820 beige flush mount adapter kit 9 mount reference connections listed temperature range range color lever color dimensions 4 Specifications terminal for in out wiring for 18 AWG to 14 AWG wire to 120 0 to 49 intended for indoor operation to 93 RH at 100 38 with white raised lettering and pull lever are high impact polycarbonate with red raised lettering in H x 3 3 4 in W x 1 in D 127 mm x 95 mm x 25 mm 5 Rev 19 02 2021 Non Addressable Manual Stations 2099 Series