Simplex Multi-Application Peripherals, Annunciators, 4605 Series 24 PT I O Annunciator Module

File Preview
File Preview
Click below to download for free

Text Preview

Multi application Peripherals Point I O Annunciator Modules for use with the 4010 Fire Alarm Control Unit ULC CSFM Listed FM MEA NYC input output module for use with the 4010 addressable fire alarm control unit FACU 4605 Series Models provide 24 input output I O points per module each point selectable as either an input or an output input switch types are supported Unsupervised switch connection Supervised for open to switch circuit Supervised for open or short to switch circuit Monitored three position H O A hand off auto switches may be Normally open N O or normally closed N C Momentary or maintained Rated 24 V at 75 mA each for operation of relays incandescent lamps current limited LEDs Selectable for continuous on or slow or fast flash communicate with the 4010 FACU using N2 serial Up to six total annunciators are supported Compatible annunciators include the 24 I O module the 4606 9101 annunciator and the 24 LED door mounted annunciator Communications are provided with extended diagnostics for quick and easy maintenance Series 24 Point I O Package availability Modular package with cabinet with or without retainer and door for to six modules Plate mounting for up to six modules for use with cabinet by others Module only for expansion or for use with mounting plate and by others 1 application for 24 Point I O Module with LCD Annunciator for reference only description 4605 Series of I O modules provide a flexible remote interface for annunciators HVAC monitoring and control output bypass utility door monitoring and emergency call switches Each I point can be selected as an input or output as determined by local outputs and inputs can be selected to be continuously on or pulsed at a slow or rate Inputs can be selected to be unsupervised supervised for circuit wiring supervised for open or short circuit wiring or to three position switches such as those used for H O A switch The 4605 series 24 Point I O module has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this document It is subject to re examination revision and possible cancellation Accepted for use City of New Department of Buildings MEA35 93E Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder are the property of Tyco Safety Products Westminster Rev 6 11 2019 Point I O Annunciator Modules for use with the 4010 Fire Alarm Control Unit description options include a module only package module or multiple modules mounted on a plate suitable for installation in separately purchased cabinets to six modules mounted in a Simplex cabinet or as door mounted 24 LED annunciators for use on the 4010 cabinet flexibility Up to six N2 communications modules may be connected to the 4010 N2 external annunciator communications bus These modules may be either 4606 9101 LCD annunciator or the 24 Point I O module selection 4605 Series graphic I O modules and accessories 1 System type select one mounted modules six maximum for use with Simplex cabinet ordered separately below mounted modules six maximum for cabinet by others 1 2 in H x 21 3 8 in W mm x 543 mm 3 4 in x 6 1 2 in mm x 165 mm only Installation reference If the 24 Point I O equipment is used for a custom graphic annunciator panel one output must be configured always on and wired to a power indicator on the front panel to meet UL requirements 2 Graphic type order quantity as required Point I O Module includes mounting hardware 3 Cabinet selection select if cabinet mounted reference 4605 8401 3 4 in x 6 1 2 in mm x 165 mm 2 Unit Cabinet mounts up to six modules with glass door and 2 Unit Cabinet mounts up to six modules without door and back box only finish option 4 Accessories select as required 3 4 in H x 25 3 4 in W x 4 1 4 in D mm x 654 mm x 108 mm trim kit voltage and switch voltage rating connections operating current rating current draw 24 per switch for open and for open LED annunciator door range range 2 5 General specifications VDC to 32 VDC system supplied external annunciator communications line from 4010 FACU blocks for wire size 18 AWG to 14 AWG 0.82 mm to 20.8 mm mA 24 VDC mA 32 VDC maximum per output 1.8 A total maximum mA when closed no current draw when open state activated state activated position 7.3 mA position 5.9 mA position 3.7 mA 60 mA 83 mA with all LEDs on to 120 0 to 49 to 90 RH non condensing at 90 32 3.7 mA 7.3 mA 3.2 mA 5.6 mA 7.3 mA 3.7 mA 5.6 mA 3.2 mA Rev 6 11 2019 Point I O Annunciator Modules for use with the 4010 Fire Alarm Control Unit reference For total current add outputs and supervisory current to module current 5 General specifications to Installation Instructions 574 348 and Field Wiring Diagram 842 063 reference 2 mounting cabinet reference drawing 3 Rev 6 11 2019 Point I O Annunciator Modules for use with the 4010 Fire Alarm Control Unit 2019 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA Rev 6 11 2019

Related Files