ULC CSFM Listed FM Approved NYC Acceptance Peripherals and MAPNET II Communicating Devices Addressable Modules IAMs IDNet or MAPNET II addressable communications both data and power over a single wire pair provide Supervised Class B monitoring of normally open dry Total wiring distance from IAM to supervision of up to 500 ft 152 m Monitored connection is compatible with Simplex Overvoltage Protectors for outdoor wiring or noisy applications For use in indoor locations up to 158 F 70 C such as spaces or similar applications use with following Simplex control panels Model Series 4007ES 4008 4010 4010ES and 4100ES alarm control panels for IDNet communications Model Series 4100 4100U 4100ES 4120 4020 and Communicating Device Transponders CDTs with MAPNET II communications 4090 9001 Enclosed design minimizes dust infiltration Mounts in standard single gang electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be after installation requires mounting bracket separately 4090 9051 Encapsulated design for extended exposure to high LED is not present on this model Color coded 18 AWG leads for wiring communications provides current limited Provides monitoring of tamper switch supervisory waterflow switch alarm on same circuit using point Available with IDNet communications only operation modes are available and are at the control panel Contact closure status can be tracked Momentary contact closure conditions can be selected at panel to be latched or tracked not available with the CDT listed to Standard 864 These products have been approved by the California State Fire Marshal CSFM pursuant Section 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this Accepted for use City of New York Department of Buildings MEA35 93E listings may be applicable contact your local Simplex product supplier for the status Listings and approvals under Simplex Time Recorder Co are the property of Fire Protection Products Supervised IAM approximately 3 4 size IDNET IN IN DEVICE NO Supervised IAM approximately 3 4 size addressable modules IAMs receive power and communications from a two wire II or IDNet circuit They provide location addressability to a single initiating device such single station smoke detector alarm contacts or heat contacts or multiple devices at the same location monitoring normally open dry contacts and the wiring an end of line resistor 4090 9001 is packaged in a thermoplastic and provides screw terminal connections and a indicating LED 4090 9051 is an encapsulated package with wire It does not provide a status indicating LED 8 2016 Operation Closure Closure of the monitored contact s an alarm or other response as programmed at the alarm control panel An open in the monitored circuit will cause a trouble to be reported Selections Selections can be made at the control to maintain the alarm condition if the initiating contacts are momentary such as from a heat detector or to track the device contact not available with the 2120 CDT IAM Product Selection Current Limited Operation Applications use with IDNet communications only these can provide quad state sensing of normal open short circuit and current limited conditions type is With the proper end of line current limiting resistors dual functions such as switch and waterflow switch monitoring can be and communicated by a single addressable Supervised IAM mounted in thermoplastic housing with screw terminals see applicable options below Supervised IAM encapsulated with wire leads Trim Plates and Mounting Bracket for Model 4090 9001 For semi flush mounted box For surface mounted box Mounting bracket mounts IAM to electrical box and provides screw holes for trim plate required for optional trim plate with LED viewing window requires 4090 9810 mounting bracket mounting screws galvanized steel Resistor Harnesses ordered separately as required No Description k 1 2 W Standard end of line resistor harness for N O contact supervision k 1 2 W k 1 2 W for current limited monitoring applications Specifications and Communications Requirements Connections Documents Distances from IAM to Contacts II or IDNet auto selected 1 address per IAM open dry contacts Screw terminals for in out wiring 18 to 14 AWG wire Color coded wire leads 18 AWG 0.82 mm2 8 long 203 mm mm2 to 2.08 mm2 Instructions 574 331 for 4090 9001 579 572 for 4090 9051 Wiring Diagrams 842 073 for IDNet operation 841 804 for MAPNET II operation ft 152 m maximum without protectors ft 122 m maximum with 2081 9044 Overvoltage Protectors ft 762 m maximum from fire alarm control panel ft 3048 m maximum total wiring distance including T Taps Distance Reference per channel MAPNET II or Communications Material 4090 9001 Material 4090 9051 Range Range 1 9 16 W x 1 3 4 H x 1 1 4 D 40 mm x 44 mm x 32 mm 1 9 16 W x 1 9 16 H x 9 16 D 40 mm x 40 mm x 14 mm thermoplastic beige to 158 F 0 to 70 C intended for indoor operation to 93 RH at 100 F 38 C 8 2016 Mounting Information IDNet IAM wiring shown reference IDNET IN IN viewing port gang electrical 2 1 2 64mm depth by others setting under resealable label gang blank cover plate and mounting screws for use when is not required to be externally viewed supplied by others Reference Single Gang Blank Cover Plate pipe for viewing mm mm mm mm Trim plate for semi flush mounted box Trim plate for surface mounted box Mounting ordered These mounting plates require mounting bracket 4090 9810 Trim Plates and Mounting Bracket for Visible LED 8 2016 4090 9051 Mounting Information setting is rear of housing IAM DEVICE NO gang electrical 2 1 2 64mm depth by others gang blank cover plate and screws supplied by others 2016 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Fire Protection Products Westminster MA 01441 0001 USA 8 2016