ULC CSFM Listed Approved Addressable Relay Module Relay IAM A single addressable point provides control and status of separate 8 A Normally Open Form A NO 8 A Normally Closed Form B NC contacts Low power latching relay design allows IDNet to supply both data and module power Operation upon loss and restoration of communications switch selectable to either reset the output relays to or to keep them latched in the selected state use with following Simplex control panels Model Series 4007ES 4008 4010 4010ES 4100ES 4100U fire alarm control panels for IDNet construction Mounts in standard 4 102 mm square electrical box adapter bracket is available to mount in a 11 square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications can be at panel to indicate activated state Optional 4 square box covers are available to allow to be viewed after installation listed to Standard 864 A Relay IAMs allow fire alarm control panels to a remotely located NO and NC contact using addressable communications for both data and power Typical applications would be for local power for control functions such as capture or control of HVAC components fans dampers etc Relay status is also requiring only one device address Selection 8 A Relay IAM Trim Plates and Adapter For semi flush box For surface box Adapter plate to fit 4 11 119 mm square plate galvanized with LED viewing includes screws box This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document Additional listings may be applicable contact your local Simplex product for the latest status Listings and approvals under Simplex Time Recorder Co are property of Tyco Fire Protection Products Peripherals IDNet Communicating Devices 4090 9010 8 A Relay IAM 8 A IDNet Relay IAM Package approximately 1 2 size communications 1 address per IAM Power Supplied by IDNet communications Ratings not rated for incandescent switching contacts 1 NO and 1 NC Voltage VAC or 30 VDC Ratings A resistive A inductive at 0.35 PF Provide circuit fusing and transient suppression as per application DC inductive loads can typically diode suppressed 120 240 VAC loads may require RC or varistors depending on device type Refer to Instructions for additional information Connections Screw terminals for in out wiring to 14 AWG wire 0.82 to 2.08 mm2 to 2500 ft 762 m from control to 10,000 ft 3048 m total wiring including T Taps with Simplex 2081 9044 Protectors H x 4 W x 1 D mm x 102 mm x 35 mm metal galvanized to 120 F 0 to 49 C for indoor operation to 93 RH at 100 F 38 C Reference Plate Range 11 2014 8 A Relay IAM Mounting Information A Relay IAM 102 mm square box 2 1 8 mm minimum depth RACO or equal supplied by others gang blank cover plate and mounting screws for when LED is not required to be externally viewed by others Reference Double Gang Blank Cover Plate mm mm supplied label to on site if controlling or 240 VAC pipe for LED viewing 116 mm Trim plate for mounted box 109 mm Trim plate for mounted box Trim Plates for Visible LED SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited 2014 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Fire Protection Products Westminster MA 01441 0001 USA 11 2014

Related Files