ULC CSFM Listed FM Approved NYC Acceptance Peripherals IDNet or MAPNET II Communicating Devices and 4090 9106 Zone Adapter Modules or MAPNET II communications compatible ZAMs Zone Adapter Modules provide addressable interface to a conventional device circuit IDC for Class B or Class A IDCs 4090 9101 Class B monitoring for 2 wire or 4 wire devices with power reset connections for devices 4090 9106 Class A monitoring for 2 wire initiating Zone device power is supplied separately typically fire alarm control panel Refer to device compatibility list on page 2 use with the following Simplex fire alarm panels Model Series 4007ES 4008 4010 4010ES 4100ES 4100U fire alarm control panels using IDNet Model Series 4100 4100U 4120 4020 and 2120 Device Transponders CDTs with MAPNET II communications sealed construction Enclosed design minimizes dust infiltration Mounts in standard 4 102 mm square electrical box Screw terminals for wiring connections Visible LED flashes to indicate communications Optional covers are available to allow LED to be after installation UL listed to Standard 864 II Monitor ZAMs allow a single point to monitor a conventional initiating circuit IDC populated with 2 wire or 4 wire devices Refer to page two for compatible This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document Accepted for use City of New York Department of Buildings MEA35 Additional listings may be applicable contact your local Simplex product supplier the latest status Listings and approvals under Simplex Time Recorder Co are the of Tyco Fire Protection Products Series ZAM Package approximately 1 2 size ZAM Input Voltage Current 24 VDC ZAM Zone Resistor k 1 W Connections or MAPNET II 1 address device to 32 VDC nominal VDC 16 mA maximum 72 mA maximum current is determined by device requirements terminals for in out wiring to 14 AWG wire to 2.08 mm2 to 2500 ft 762 m from fire control panel to 10,000 ft 3048 m total distance including T Taps with Simplex Overvoltage H x 4 W x 1 D mm x 105 mm x 35 mm thermoplastic or MAPNET II Material Plate Material Sheet metal galvanized Range Range to 120 F 0 to 49 C for indoor operation to 93 RH at 100 F 38 C 11 2014 Product Selection Modules Zone Adapter Module for Class B monitoring of 2 wire or 4 wire initiating devices with power reset for 4 wire devices Zone Adapter Module for Class A monitoring of 2 wire initiating devices Adapter and Trim Plates Adapter plate to fit 4 11 119 mm square electrical box For semi flush mounted box For surface mounted box Resistor Harness No Description plate with LED viewing window includes mounting screws steel k 1 End of Line Resistor Harness for 4090 9101 Class B zone monitoring Monitor ZAM Two Wire Initiating Device Compatibility Reference Chart connect photoelectric smoke detector Bases Quantity base required heat detectors smoke detectors smoke detector for Existing Equipment detectors heat detectors detector housing with 4098 9601 detector Bases Quantity Four wire detector operation is compatible with conventional listed contact closure initiating devices Four wire detectors require detector voltage to be connected to resettable power terminals Refer to installation instructions 574 183 and field wiring diagram 842 073 for additional information Contact your local Simplex product supplier for additional compatible devices 11 2014 ZAM Mounting Information setting under label 102 mm square box 2 1 8 mm minimum depth RACO or equal supplied by others ZAM gang blank cover plate and mounting screws for when LED is not required to be externally viewed by others Reference Double Gang Blank Cover Plate mm mm pipe for LED viewing 116 mm 109 mm Trim plate for semi flush mounted box Trim plate for surface mounted box Trim Plates for Visible LED 11 2014 SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited Fire Protection Products Westminster MA 01441 0001 USA 11 2014 2014 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice