Simplex Multiport SLI Option™ Installation Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-multiport-sli-option-installation-instructions-8506731429.pdf |
---|---|
Type | |
Size | 805.59 KB |
Downloads |
Text Preview
Cautions and Warnings Documentation You Begin SLI Option Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of the for shipping damage If damage is apparent immediately file a claim the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore as follows Ground yourself before opening or installing components Keep uninstalled component wrapped in anti static material at all times publication describes the installation procedure required to complete the of three or more 2120 BMUXs to a Graphical Command Center or a Network Processing Unit NPU using a Serial Line Interface SLI you are connecting less than three BMUXs to the NPU GCC refer to respective installation instructions listed below following is a list of additional documentation that may help you when the GCC NPU 4100 4120 UT Back Box Installation Instructions FA4 21 203 Ferrite Beads with Media RS485 Cards FA4 21 235 4120 Network Processing Unit NPU Parts List NET 21 010 4120 Network Processing Unit NPU Installation 574 314 Network Concepts NET 91 050 NPU Field Wiring Diagram 841 947 4120 Graphical Command Center GCC Installation 4120 Graphical Command Center GCC Checkout Instructions NET 21 100 Instructions NET 31 101 Color Graphics Operating and Editing Instructions User Levels 3 and 4 MUX2 41 301 you can successfully install three or more 2120 BMUXs to the you must have the completed the hardware and software installations in the following publications 4120 Graphical Command Center GCC Installation and Checkout NET 21 100 No 574 314 4120 Network Processing Unit NPU Installation Instructions 1996 Simplex Time Recorder Co Gardner MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice A Overview Requirements attempt any portion of the installation based strictly on steps section provides a general overview of the entire installation process These steps are intended as a general overview only Do all required hardware and software applicable to the GCC and NPU GCC NPU Software must be Rev 2.01 or higher 4100 Software must be at Rev 8.01 or higher 2120 Firmware must be at Rev 5.44 or higher Network Cards firmware must be Rev 3.02 or higher the SLI Multiport Box in the appropriate location refer to the installation type desktop wall mount or rack mount box Refer to the field wiring diagrams for all wiring Complete following steps for EACH BMUX 4 max for GCC NPU w 486 and 8 max for GCC w Pentium you want to install on the network Wire the field wiring from the suppressor part number 620 970 to the Wire the 733 572 harness to the junction box Connect the DB25 male connector to the RS232 port on the 2120 Connect the DB25 female connector on the 3 foot interface cable to the Configure all points in the 2120 as if connected to a CGU and use the in the Installing the 2120 Serial Point Collection Utility of this publication to complete a 2120 point dump to your PC port on the SLI Multiport box then connect the DB25 male to the port on the SLI card in the GCC NPU 1 lists the required hardware for successful installation and operation of or more 2120 BMUXs connected to a GCC NPU Figure 1 shows the diagram for each harness assembly to the RS 232 port on a 2120 BMUX 1 Required Hardware to Install Three or More 2120 BMUXs a GCC NPU Number GCC NPU Multiport Kit Assembly Harness Assembly on next page Continued Requirements 6 5 4 3 2 earth 1 D C B A 620 970 shield is used A B C Installed Cable is typically 18AWG 2 pair twisted BOX RS232 Multiport Box 2 describes the connections of the 733 572 harness to the SLI Multiport Box 1 Wiring Diagram for Suppressor to Junction Box 1 describes how to wire the 733 572 harness from the junction box to the RS232 port Even though Wire D has a termination point on the there is no connection for Wire D inside the junction box Refer to wiring diagram for all wiring Connect each BMUX to its corresponding port on the SLI Multiport box as in Table 2 2 SLI Multiport Box Cables and Connectors on SLI Box interface cable female connector port number 733 572 BMUX 1 number 733 572 BMUX 2 number 733 572 BMUX 3 number 733 572 BMUX 4 number 733 572 BMUX 5 number 733 572 BMUX 6 number 733 572 BMUX 7 number 733 572 BMUX 8 0 1 2 3 4 5 6 7 on next page Continued Multiport Box 2 lists the DB25 female connector pin assignments for the ports on the SLI Box 3 Pin Assignments DB25 Female Connectors ground through 14 through 24 used used used used used used used used used Types GCC is available in two versions Desktop or Rack Mount The NPU is available in two versions Rack Mount or Wall Mount The following describe the installation steps for each version of the GCC NPU Refer the instructions that apply to your specific type of installation Wall Mount Versions order in which you install the SLI Multiport box in a Wall Mount version is important For a successful installation complete the steps in the order listed Figure 2 shows the connections involved in a Wall Mount on next page Continued Types 2 SLI Multiport Box Installation in Wall Mount NPU On the NPU install the SLI Multiport box bracket within 3 feet of the CPU on the left side of the back box using the three 6 32 screws provided Slide the SLI Multiport box on to the bracket Connect the DB25 female connector on the 3 foot interface cable to the Host on the SLI Multiport interface box Securely attach the DB25 male connector of the 3 foot interface cable into port on the CPU bay Make sure that your connector is attached to the SLI Wire the field wiring from the junction box to the 620 970 suppressor Refer not to the printer port The SLI card in the NPU the only card with a centered DB25 female connector the field wiring diagram in Figure 1 for all wiring Securely attach all suppressors to the SLI Multiport box on next page Continued Types Desktop Versions 3 shows how to install the Desktop Version of the GCC Card