Simplex MX Gen6 Series Brochure

File Preview
File Preview
Click below to download for free

File Data

Name simplex-mx-gen6-series-brochure-9354180276.pdf
Type PDF
Size 2.93 MB
Downloads

Text Preview

www simplex fire com 2020 Johnson Controls All rights reserved GEN6 SERIES LEADER IN DETECTION products are known for leading innovation One way we do this is enhancing our sensor technology to provide our customers with the most solutions for the varied challenges they encounter our long history we have perfected the capabilities intelligence and inside our sensors to improve safety even the most challenging environments innovation Each year we invest millions of dollars and countless hours in the of new technologies to help safeguard lives property and the environment and revolution Supported by our advanced research and development facilities modern manufacturing platforms throughout the world our solutions deliver measurable performance and sustainability and reliability We understand that a fire detection system is crucial to the safety protection of a building and its occupants People rely on this system every day to help keep safe and alert them at the earliest possible sign of danger Gen6 series sensors have been developed to help ensure optimum detection performance and false alarm resilience focus At the forefront of innovation we pride ourselves on an ongoing commitment integrate insights from people who use and interact with our products ensuring we are always and developing the most innovative new solutions work with our customers to achieve their safety and business goals by finding smarter ways to where people live and work a promise we have delivered on for more than 100 years Gen6 Series sensor technology new MX Addressable Fire Sensor technology enhances performance environmental performance fire sensors in a room are constantly information on the levels of heat smoke to the panel The panel uses FastLogic algorithms to information from the sensor determine whether there is a fire in conjunction with the of Duisburg FastLogic is based analysis of data from nearly 100,000 fire situations gathered over 80 This makes systems with FastLogic exceptionally good at detecting fires and rejecting false alarms detection fault tolerance easier and quicker to install lifetime cost calculates that the sensor response a high probability of a fire In many FastLogic is able to detect fires more and accurately the door a steam filled bathroom Alarm Alarm the sensor reaches the threshold for long to cause an alarm FastLogic analyzes the pattern and calculates a low probability of it a fire In this example FastLogic prevents initiation of a false alarm FastLogic is designed achieve faster of real fires Center system you can rely on MX Gen 6 series sensor range is designed for variety of environments and can be configured to superior detection for numerous fire risks Gen6 Series sensor range Photo Sensor Photo Sensor with Isolator choice of several programmable sensitivities gives sensor a broad range of applications optical sensor can help to protect in benign environments potential fires would be slow burning Modes Sensor Heat Sensor Heat Sensor with Isolator operate in fixed temperature and rate of rise modes with number of approved sensitivities in areas where high levels of dust are present or where environment precludes the use of smoke sensors Modes of Rise Heat Temp 135 Deg F Temp 200 Deg F Fixed Temp Rate of Rise Operation Photo Heat Sensor Photo Heat Sensor with Isolator to detect a wide range of fires flaming to smouldering types photo and heat multi sensor device is the preferred for a range of applications including light industrial and office environments in a number of configurations and sensitivities that be dynamically selected via software to suit different conditions Modes Photo High Sensitivity Photo High Performance Photo Photo Fixed Temp Heat Photo Rate of Rise Heat Heat Rate of Rise or Fixed Temperature Triple Sensor with Isolator multi sensor technology leading false alarm protection smoke heat and CO levels simultaneously to quickly and accurately determine the presence of fire alarm rejection properties make it the ideal choice hotel bedrooms where steam from bathrooms a common source of false alarm for use when the environmental conditions challenging for example industrial transport hubs and healthcare Modes Photo CO Heat Photo Rate of Rise or Fixed Temperature Toxic Enhanced Simplex Gen6 series sensors have the flexibility to alter the sensitivity to heat CO and depending on the application and time of day from choosing the correct it is important that each is set to the operating mode suits the area being protected multi sensors provide the to dynamically adapt to environment depending on the risk levels and part of day The mode of operation will sensitivity to smoke heat CO helping to ensure optimum at all times modes of operation can used concurrently with both the and Gen6 multi sensors an example a Gen6 multi sensor operate as a high performance sensor a heat sensor and heat compensated CO sensor with different alarms different actions ability to employ multiple can be used to provide alarm without the need for devices diesel ferry deck room beds right sensor mode for requirements challenges large commercial buildings there are multiple tenants occupying the for different activities including space call centers dining areas shops and gyms It is a challenge find detection solutions that can satisfy needs of a multi use building and help eliminate alarms series multi sensors help to protect a wide of environments of manufacturing processes such as dust heat and smoke can a difficult environment for the fire system and are frequent causes false alarms a hotel environment en suite shower will often generate steam when use This could trigger a photoelectric resulting in a false alarm and to customers Series multi sensor devices can help overcome many challenges multi sensor device has six detection and employs three detection heat smoke and toxic gas monoxide sensors can be used in concert to optimum detection based on the and risk an ideal solution for buildings with varying fire needs as sensor modes can adjusted to suit each environment modes can be as easy as a button on the panel or if change is required it only takes simple software reconfiguration Quick and no hardwired changes required highly desirable feature for applications is the Gen6 multi sensor device programmable and night modes This means that the day when the building is fully and running heat and CO can monitor for fire while the elements can be turned off or set low sensitivity Smoke elements can be back to their normal mode at night daily activities have ceased and the is likely to be most at risk ability to adjust and set the sensitivity of the Gen6 series is an important in hospitality settings hotel motel dormitories and other similar With the ability to set the to low sensitivity to steam from while it remains highly sensiti

Related Files