Simplex MX Technology Addressable Devices; Loop Powered General Signaling Sounder-Beacons for Indoor and Outdoor Applications
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-mx-technology-addressable-devices-loop-powered-general-signaling-sounder-beacons-for-indoor-and-outdoor-applications-9362418075.pdf |
---|---|
Type | |
Size | 852.51 KB |
Downloads |
Text Preview
Listed Technology Addressable Devices Loop Powered General Signaling Sounder Beacons Indoor and Outdoor Applications Technology addressable sounder beacon MX loop powered with internal isolator separate is not required Listed to UL 464 for general signaling operation Available for indoor mounting in red or white and for mounting in red and outdoor sounder beacons include a surface mount box with tamper resistant release tool is supplied Selectable output volume of 90 dB or 103 dB Sounders Beacons on the same MX Loop are Output sound patterns are selectable from the MX Module to be March Time 60 bpm Slow Time 20 bpm or Continuous LED beacon flash rate is selectable as either once per 1 Hz or once every 2 seconds Hz Address and sounder beacon selections are easily with the MX 850EMT Engineering Tool For use with Simplex 4100ES and 4010ES Series fire control panels equipped with an MX Loop Refer to data sheet S4100 0059 for MX Loop Module Refer to specifications section for wiring requirements Loop Powered Sounder Beacons use MX communications for control and power models are available in red or white The outdoor is in red these loop powered sounder beacons supervision is using MX loop communications and then can be activated with the tone selection controlled the MX Loop Module Beacon flash rate is selected the sounder beacon using the MX 850EMT Management Tool Listings and approvals under Simplex Time Recorder Co are the property of Tyco Fire Products Indoor Red Sounder Beacon Indoor White Sounder Beacon Outdoor Red Sounder Beacon 3 2015 Description White Sounder Beacon with box mm W x 108 mm H x 96 mm D x 4.25 x 3.78 Outdoor Sounder Beacon mounting box mm W x 110 mm H x 105 mm D x 4.33 x 4.13 MX Engineering Management Tool ref MX Model 850EMT installation diagnostic and programming tool MX Ancillary Program Lead Spare MX Service Tool Accessory Kit Package of 10 spare pins for ancillary programming lead Loop Supervisory Current mA Setting Low Volume Sounder Volume Sounder Output for general signaling 90 dB 3 dB 3 m 10 ft dB 3 dB 3 m 10 ft Hz Flash 6.5 mA Hz Flash 7.6 mA mA mA Product Selection Specifications Level and Current Connections Wiring Requirements blocks for wire size 0.5 to 2.5 mm2 20 to 14 AWG provide segregation between fire alarm devices and general signaling sounders into and out of these sounder beacons must be connected through the MX Loop Sensor Bases Loop Powered Sounder Base Loop Powered Sounder Beacon Base 4 Continuity Base the 4090 5206 Line Isolator to data sheet S4098 0051 for MX Loop Sensor Base details and data sheet for Line Isolator details Models Model Instructions Temperature 0 C to 49 C 32 F to 120 F Temperature 25 C to 70 C 13 F to 158 F up to 95 RH non condensing Rating EN60529 Temperature 40 C to 66 C 40 F to 151 F Temperature 25 C to 70 C 13 F to 158 F Rating SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited 2015 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Fire Protection Products Westminster MA 01441 0001 USA 3 2015