UL ULC CSFM Listed FM Approved Approved Annunciator Panels for ES Network ES Net Network Display Units with Voice Command Center and ES PS Power Supplies for Net with ES Network ES Net Display Unit NDU provides annunciation for up to network points The basic Network Display Unit NDU includes an ES Net network card and functions as a special purpose master controller to providing annunciation of up to 12,000 network points An NDU with a Voice Command Center VCC mounted in the same provides an additional separate Network node with the full of a 4100ES fire alarm control unit including the ability to as the Network Voice Command Center master controller equipment top bay Master controller assembly with operator interface CPU with dual configuration programs convenient service port access capacity for up to 12,000 points ES power supply ES PS and charger 9.5 A total 12.7 A when using fan module 4100 5131 with on board alarm relay and auxiliary power output Models available with Color ES Touch Screen Display Monochrome 2 x 40 Character Display or Monochrome InfoAlarm Display Construction that is optimized for easy installation upgrade and Glass door ordered separately provides view of available operator visible behind locked door addressable interfaces include Remote annunciator module support via RUI remote unit interface port option modules include DACT and City Connection Service modems for remote panel status inquiry RS 232 ports for printers or maintenance terminals Alarm relays and expansion power supplies Remote Unit Interface 24 Point I O Fiber Optic Modems Physical Bridge BACpac Ethernet Interface SafeLINC Internet Interface Master Clock Interface equipment second expansion bay VCC includes ES Power Supply ES PS and battery charger 9.5 A up to 12.7A when using optional fan module 4100 5131 with function auxiliary power output For additional information on supported 4100ES basic panel features specifications refer to data sheet S4100 1031 Voice control options are similar to a networked fire alarm control unit an extensive list of modules available for initiating notification user interface refer to data sheet S4100 1034 for details 1 Network one line diagram showing an NDU with VCC information UL 864 Fire Detection and Control UOJZ Smoke Control Service Releasing Device Service SYZV Emergency Communication Relocation Equipment UOQY UL 1076 Proprietary Alarm Units Burglar APOU UL 2017 Process Management Equipment QVAX Emergency Alarm Control Units FSZI UL 1730 Smoke Detector Monitor UULH UL 2572 Mass Notification Systems PGWM CAN ULC S527 Control Units for Fire Alarm Systems UOJZ7 Releasing Service SYZV7 CAN ULC S559 Central Station Fire Alarm System Units DAYR7 ULC ORD C1076 Proprietary Burglar Alarm Units and Systems APOU7 ULC ORD C100 Smoke Control System Equipment UUKL7 This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7165 0026 0251 for allowable and or conditions concerning material presented in this document Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Fire Protection Products S4100 1077 Rev 9 10 2021 Network Display Units with Voice Command Center and ES PS Power Supplies for ES Net Feature Summary Selectable service override allows authorized operators to clear alarm during system reset even if status has gone to trouble reset occurred Duplicate address error detection Convenient PC programming using a Microsoft Windows user interface program Interface Detail Reference Fire Alarm Control Units are provided with either an enhanced ES Touch Screen Display or a basic Monochrome 2 Line by 40 operator interface depending on the model selected for on Monochrome InfoAlarm display refer to data sheet The following illustrations highlight the primary functions of 4100ES NDU with VCC for ES Net is a network level annunciator manual system point controller with optional network voice control It provides alphanumeric annunciation for up to 12,000 points and or point lists and can be programmed to function as network master controller for Alarm Silence Trouble Acknowledge System Reset Net Network Overview connected to other ES Net network nodes individual fire alarm units become components of a distributed intelligence system panel that directly connects to the ES network is called a network and is capable of performing individual supervision and control its locally connected devices but has the ability to inform the 4100ES as well as other network control panels of point status and panel This allows system information to reach the proper location appropriate system response 4100ES NDUs separately packaged can be connected to an network to duplicate common information at separate locations or selected information by type such as troubles alarms control etc Module Bay Description NDU Master Controller Bay top includes a special purpose ES supply with battery charger ES PS the master controller board ES network interface card expansion space for optional features and interface equipment similar to that used on the standard fire control modules Optional NDU VCC includes an expansion bay with separate controller board ES network interface card expansion space optional features and an ES PS power supply This results in two network nodes residing within the same cabinet LED switch modules can also be mounted in the VCC bay For cabinets the VCC mounts in bay 2 For 3 bay cabinets as shown to right the VCC mounts in the second expansion bay bay 3 Battery Compartment bottom accepts two batteries up to 50 to be mounted within the cabinet without interfering with module to the NDU with VCC internal module bay reference illustration for three bay cabinet module location Availability Modules are power limited unless specifically noted otherwise Enclosure are available for one two or three bay sizes or for cabinet mounting Additional cabinets can be mounted close nippled for module NEMA 1 IP30 boxes doors with tempered glass inserts and dress are available in platinum or red ordered separately Refer to data sheet S4100 0037 for enclosure details 2 ES Touch Screen Display Interface 3 Monochrome 2 Line x 40 Character Display 2 S4100 1077 Rev 9 10 2021 Network Display Units with Voice Command Center and ES PS Power Supplies for ES Net ES Touch Screen Display Color ES Touch Screen Display interface offers intuitive operation similar to a tablet or smart phone With a larger area format versus an individual line display more information is available at a glance and minimal key presses are needed to access detailed information 4 ES Touch Screen Display Operator Interface Touch Screen Displays provide customized operating experience Event activity display choices include First 8 Events or First 7 Events with emphasis on Most Recent or First 6 Events with emphasis on First and Recent individually selectable for each event type System reports are easily viewable logs can be read with minimal scrolling Up to two languages are available per system easily selected by programmable key press Information sent to Remote ES Touch Screen Displays can be vectored by point or zone Both Hard and Soft keys available for critical functions Event Acknowledge Alarm Silence and Reset Functions Resistive touchscreen technology allows operation with or without gloves Seven programmable RGY LEDs available for user defined display status up to 2 status conditions per LED Seven programmable Soft keys available for user defined control or maintenance functions PRI2 Soft key label can be changed to CO to annunciate Car