Simplex Non-Addressable Initiating Peripherals; Reflective Beam Smoke Detectors Fire Fighting Enterprises Auto-Aligning Fireray 5000

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Initiating Peripherals Reflective Beam Smoke Detectors Fighting Enterprises Auto Aligning Fireray 5000 to two detector heads can report to one level controller transmitter and receiver are in a single compact housing An infrared beam is reflected from a matching prism the reflected light analyzed by an on board providing area smoke detection Operating range covers 26 ft 3 inches to 330 ft m to 100 m Modular design with easyfit mounting system and assisted prism mounting provides convenient and adjustment Auto Align beam alignment operation conveniently beam to align to the prism center during AutoOptimise operation automatically maintains for reliable operation 5 Year Warranty UL listed to Standard 268 controlled operation includes Easy setup and alignment with sensitivity selectable 10 to 60 35 default Password protected settings Built in electronic UL ULC obscuration acceptance test Automatic gain control contamination compensation building shift compensation Current monitoring for gimbals motor position Ground level system controller with LCD provides user of operating parameters remote status display access and test Operating voltage range of 14 to 36 VDC Alarm latching or alarm auto reset Separate alarm and trouble contacts for each detector Large open areas such as warehouses hotel atriums plants and school gymnasiums Public areas where cosmetics are of prime importance detector heads need to be small and unobtrusive malls libraries theaters and churches Accessories Detector adjustment bracket back box and cover plate Controller back box Extended prism mounting options Listings are by Fire Fighting Enterprises Refer to CSFM 7260 1508 104 5000 Reflective Beam Detector Head 5000 Control Station Convenient Installation and Alignment The Fireray System is an auto aligning infrared beam smoke Once the detector head is installed using the mounting system an integral LASER can be that is aligned along the optical path of the beam allowing the reflective prism to be located and with confidence The Auto Align beam feature then allows the reflective prism to be quickly and accurately Beam Alignment The AutoOptimise alignment system automatically steers and maintains beam in the optimum position for reliable performance signal is generated in the transmitter element and by the prism back to the receiver element then for the presence of smoke The internal determines an alarm condition when a level is reached The maximum distance of Detector and Reflector from the ceiling must be 10 of distance between floor and ceiling Lateral detection be up to 30 ft 9.144 m on either side of the beam a maximum total coverage area of up to 19,800 feet 60 ft x 330 ft or 18.29 m x 100 m Note Reflective beam smoke detectors may be suitable for areas with highly reflective surfaces transmitter receiver models may be required to the Installation Instructions supplied with the and to NFPA 72 the National Fire and Signaling for additional installation guidance 8 2013 Specification projected beam type smoke detector shall be listed to 268 and shall consist of up to two integrated receiver detector heads and single low level control unit The detector shall operate between a of 26.25 ft to 330 ft 8 m to 100 m The range of the system shall be 4 F to 131 F C to 55 C The beam detector heads shall include integral built in laser pointer to assist prism mounting beam detector shall feature automatic gain control will compensate for gradual signal deterioration dirt accumulation on the lenses The beam detector shall include AutoOptimise Self Correcting head feature to ensure unit is always receiving signal available and shall automatically for Building Shift Ordering Information unit shall include a low level remote display and unit with LCD readout for set up reporting and of up to two separate detector heads The system be capable of programming obscuration thresholds 10 to 60 in 1 increments The system shall be of programming delay to fault and delay to alarm 2 seconds to 30 seconds in 1 second increments and acceptance of the system shall be carried out by the UL approved internal electronic obscuration fire The projected beam type smoke detector shall be a 24 VDC device to be used with a Nationally Testing Laboratory Listed separately 4 wire control panel The Reflective beam type detector shall be a Fire Fighting Enterprises 5000 5000 Reflective Auto Align Beam Smoke Detector includes one detector head one controller and one for control of up to two detector heads Detector Head and Prism select up to one additional head per System Series Detector Uni Box back box includes hinged cover plate knock outs on all sides captive screw lock on cover plate universal plate mounting holes and cover plate mounting holes for optional wire cage box may be surface or flush mounted Cover Plate for mounting 5000 Series Detector to a double gang box surface or flush mount Bracket for detector or prism surface mount pivots horizontally vertically for accurate alignment order detector and prism parts Bracket for detector or prism surface mount provides 360 plus 130 adjustment for accurate alignment order detector and parts separately Back Box surface or flush mount mounts to single gang double or 4 square box for surface mounting Back Box Semi Flush Mount Trim Plate for 5000 009 box 9 H x 5 5 W x 5 9 D mm x 134 mm x 132 mm H x 7 W x 2 13 D mm x 200 mm x 71 mm x 3 15 x D mm x 100 mm x 9.5 mm 9 H x 5 5 W x 5 9 D mm x 134 mm x 132 mm square x 2 1 D mm x 52 mm cover plate 7 square 164 mm 3 lip 5 mm square footprint x 2 13 D mm x 71 mm 27 H x 3 29 W mm x 99.5 mm 7 H x 7 7 W x 1 D mm x 189 mm x 45 mm 5 H x 8 W mm x 222 mm mm x 211 mm x 13 mm 3 x 8 5 x D Wall Mount Bracket mounts a single prism for up to 160 ft 49 m or prisms for 160 ft to 330 ft 49 m to 100 m prisms are ordered Prism Alignment Adapter mounts on 5000 005 Alignment Bracket Prism and Alignment Bracket separately Prism Alignment Adapter mounts on 5000 005 Alignment Bracket Prisms and 5000 005 Alignment Bracket separately Prism Range Prism Kit provides three 23901 Prisms for distances between 160 ft and 330 ft 50 m to 100 m Pendant Mounting Bracket Wire Cage for 5000 Series Detector Heads Wire Cage for 5000 Serie4s Controllers square 102 mm square 204 mm Ordering Note These products can be found in Job Design under Fire Fighting Enterprises OP category OPFFE 8 2013 Accessory Reference not shown to scale Detector on Alignment Bracket Detector on 5000 011 Uni Box Prism Reflector Prism on Mounting Bracket Prisms on Mounting Bracket Single Prism Adapter a 5000 005 Alignment Bracket Adj

Related Files