Simplex Non-Addressable Initiating Peripherals, Reflective Beam Smoke Detectors, Fire Fighting Enterprises Models 50RU and 100RU
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-non-addressable-initiating-peripherals-reflective-beam-smoke-detectors-fire-fighting-enterprises-models-50ru-and-100ru-7413928605.pdf |
---|---|
Type | |
Size | 1.25 MB |
Downloads |
Text Preview
UL ULC CSFM Listed NYC Acceptance transmitter and receiver are in a single compact housing An infrared beam is reflected from a matching prism the reflected light analyzed by an on board providing area smoke detection Two models are available Model 50RU is for 15 ft to 160 ft 5 m to 50 m Model 100RU is for 160 ft to 330 ft 50 m to 100 m Each model includes the matching prism reflector s wall mounting bracket and a calibrated test filter UL listed to Standard 268 controlled operation includes Easy setup and alignment with three selectable alarm of 25 35 or 50 beam obscuration can mounted horizontally or vertically Operation at either 12 VDC or 24 VDC Alarm latching or alarm auto reset Automatic gain control Separate alarm and trouble contacts Open areas where ceiling height exceed 25ft 7.6 m hotel atriums industrial plants and school Public areas where cosmetics are of prime importance detector heads need to be small and unobtrusive malls libraries theaters and churches Reduces installation costs where 6 or more spot are required in a single area Optional remote test station mounts at ground level and service time by testing without site disruption Accessories Surface mount matching backbox Extended alignment bracket Remote Test Station Unit Design A single unit houses both an transmitter and receiver The transmitter signal is by a matching prism back to the receiver where internal microprocessor analyzes it for the presence of An alarm condition is determined when the sensitivity level is reached Detectors are mounted with the beam between 1 ft 305 mm and 2 ft 610 mm and parallel to the ceiling Lateral detection may up to 30 ft 9.144 m on either side of the beam a maximum total coverage area of up to ft2 60 ft x 330 ft or 18.288 m x 100 m Initiating Peripherals Reflective Beam Smoke Detectors Fighting Enterprises Models 50RU and 100RU Reflective Beam Detector shown without mount bracket and LLC Remote Test Station Continued Note Reflective beam smoke detectors may be suitable for areas with highly reflective surfaces transmitter receiver models may be required Specification projected beam type smoke detector shall be a 4 wire VDC device to be used with a UL Listed separately 4 wire control panel Unit shall be listed to 268 and shall consist of an integrated transmitter and The detector shall operate between a range of ft to 330 ft 5 m to 100 m The temperature range of beam shall be 4 F to 131 F 20 C to 55 C 268 listed temperature range is 32 F to 100 F 0 C 38 C The beam detector shall feature automatic gain which will compensate for gradual signal from dirt accumulation on the lenses The shall include a wall mounting bracket Testing shall carried out by using a calibrated obscuration test filter Reflective beam type smoke detector shall be a Fire Enterprises 50RU 160 ft 50 m or 100RU ft 100 m Detector Spacing smooth ceilings up to 60 ft 18.288 m between beams and not more than one half the spacing a reflective beam and a sidewall Other spacing be used depending on ceiling height airflow and response requirements to NFPA 72 and Installation Instructions supplied unit for further information Listings are by Fire Fighting Enterprises Refer to CSFM 7260 1508 102 and MEA 70 02 E product was not approved by FM as of document revision date 12 2011 documentfirealarmresources com Ordering Information Number beam smoke detector 160 ft 50 m maximum distance beam smoke detector 330 ft 100 m maximum distance Test Station Low Level Controller 0400 single gang mount provides remote Power on Alarm LED and remote Alarm Test Prism Note Model 100RU uses 4 prisms Model 50 RU uses 1 prism mount matching backbox Alignment Bracket allows up to 45 adjustment for either detector or prism Protective Wire Cage Ordering Note These products can be found in Job Design under the Air Products OP category OPFFE Additional Product Details not shown to scale Detector Surface Mount shown with 1000 020 Cage Specifications Specifications housing only with bracket Dimensions Specifications Voltage Current Current and Trouble Relays Method Wavelength Specifications Time Time Distance Indicators Types Conditions Listed Temperature Range Temperature Range Humidity Retardant ABS IP rating IP50 H x 4 3 4 W x 4 1 2 D 210 mm x 121 mm x 114 mm H x 5 W x 4 3 4 D 210 mm x 126 mm x 121 mm square x 3 8 D 100 mm x 9.5 mm each is used by the Model 50RU four are used by the Model 100RU Fighting Enterprises A Halma Group Company website www ffeuk com to 30 VDC mA 24 VDC mA 24 VDC separate Form C relays rated 1 A 30 VDC resistive connector with attached wire leads nm seconds seconds maximum 35 or 50 obscuration 15 ft to 160 ft 5 m to 50 m 160 ft to 330 ft 50 m to 100 m Red LED Amber LED latching or non latching operation setup alignment 90 or more obscuration F to 100 F 0 C to 38 C F to 131 F 20 C to 55 C to 93 RH non condensing SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code trademarks of the National Fire Protection Association NFPA Fire Protection Products Westminster MA 01441 0001 USA 12 2011 2011 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice documentfirealarmresources com