Simplex Non-Addressable Peripherals; 4905-9835 Temporal Code 4 Module for CO Gas Alarm Notification; S4905-0006
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-non-addressable-peripherals-4905-9835-temporal-code-4-module-for-co-gas-alarm-notification-s4905-0006-1257803694.pdf |
---|---|
Type | |
Size | 1.06 MB |
Downloads |
Text Preview
Non Addressable Peripherals Temporal Code 4 Module for CO Gas Alarm Notification 1 Temporal Code 4 Module Control NAC Current NAC Current Distance to NAC Source Connections Plate Range Range 1 Specifications 24 VDC NACs up to 3 A maximum by input NAC rating for control of notification appliances compatible TC4 code pulse duty cycle current 0.18 mA current 15 mA current 0 mA current 3 mA close nippled 20 ft 6 m maximum terminals for in out wiring 18 AWG to AWG wire 0.82 mm2 to 3.31 mm2 in H x 4 1 8 in W x 1 3 8 in D mm x 105 mm x 35 mm metal galvanized to 120 0 to 49 device is intended for indoor operation to 93 RH at 100 38 ULC CSFM Listed FM Temporal Code 4 TC4 NAC Notification Appliance control for Carbon Monoxide CO gas warning The TC4 CO gas warning is a repeated sequence of four cycles of msec on with 100 msec off followed by 5 seconds off per NFPA Standard for the Installation of Carbon Monoxide CO Warning in Dwelling Units Compatible appliances includes CO Sounder Bases 4098 9771 and 4098 9773 4901 9820 Horn set for free run 49CMT multi tone Horns set for free run Horn tones and 4903 Series A V appliances Horn input not compatible with SmartSync horn appliances Simplex equipment NAC sources 4007ES Hybrid 4010ES 4100U and 4100ES NAC outputs 4009 IDNet NAC Extender NAC outputs Each module requires an input NAC that powers the 3A rated out NAC for control of compatible audible notification appliances only for strobes operation modes Synchronized operation facilitates a separate and dedicated control to both activate and synchronize the Temporal Code 4 output of up to 20 4905 9835 modules Unsynchronized operation also facilitates the separate and dedicated NAC to activate the Temporal Code 4 output timing of up to 4905 9835 modules but without synchronization between the Stand Alone operation facilitates the input NAC in alarm to activate Code 4 timing for NACs dedicated for CO gas alarm no fire signals are available no control NAC is used For both Synchronized and Unsynchronized modes when the NAC is off the module output NACs will follow the fire alarm sig of the input NAC For TC4 output both the input NACs and the control NACs a Steady On signal sealed construction Mounts a standard 4 in square electrical box Compatible with Adapter Plate 4090 9813 to fit 4 11 16 in 119 mm electrical boxes Screw terminals for wiring connections to UL 864 and ULC S527 gas alarm warnings gas alarm warnings are different to fire alarm warnings In the event a CO gas alarm a Temporal Code 4 audible pattern signals the type condition to the responders and helps them determine the proper gas alarm or fire alarm of the 4905 9835 Temporal Code 4 Module facilitates the NFPA 720 Code 4 signal to generate using a standard Steady On audible NAC input Under the fire alarm panel s control the audible signal is selected for a conventional fire pulse pattern for a alarm condition This product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7300 0026 328 for allowable and or conditions concerning material presented in this document This product was not accepted by MEA NYC as of document revision date Additional listings may be applicable contact your Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co are the property of Tyco Fire Protection Products Rev 7 1 2020 Temporal Code 4 Module for CO Gas Alarm Notification Connection Reference figure shows a system connected with the 4905 9835 Temporal Code 4 TC4 Module and notification appliances the examples shown are the Horn and the 4903 Series 4 wire A V Horn Reference 2 Connection Reference 3 Reference 2 Rev 7 1 2020 Temporal Code 4 Module for CO Gas Alarm Notification Reference 2 Additional Reference Instructions Sensor Base data sheet Basic Reference Hybrid data sheet Control Panel Horns Series 4 wire A Vs Series Multi Tone Horns 3 Rev 7 1 2020 Temporal Code 4 Module for CO Gas Alarm Notification 2020 Johnson Controls All rights reserved All specifications and other information shown were current as of document revision and are subject to change without Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA Rev 7 1 2020