Simplex NT 3400 Security Management Information System, Release 2 2
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-nt-3400-security-management-information-system-release-2-2-2935406781.pdf |
---|---|
Type | |
Size | 1.10 MB |
Downloads |
Text Preview
3400 Management System SMIS 3400 SMIS File Server with Typical Operator Screen features shown are optional Features Access control event and alarm management Microsoft Windows NT Operating System Supports the following access control policies to the Simplex Intelligent System Controller Optic Site Dialup Modems Optional and privileges rule restrictions rule card assignment routing trace alarm response codes database fields time zone correction input output linking Provides the following access control management Report management Distributed processing for system reliability Elevator control Cardholder Database partitioning 2.2 Features Badging System Control Image Verification Graphical Maps Reports File Server refer to data sheet S3400 0019 for details with special application UL Listings chart on page 8 NT 3400 is a scalable Security Management System designed to accomodate a wide of integrated security requirements The NT 3400 is in three full featured models with graduated NT 3400 incorporates the power of the Microsoft NT operating system Pentium III based computers and an industry standard relational The NT 3400 utilizes the familiar User Interface GUI with the power true multi tasking performance Fully integrated 3400 functions include Access Control Alarm CCTV Interface dynamic Graphical Maps Badging and Video Image Verification Card Readers Cardholders 3400 A 3400 B 3400 C Options 2 5 16 Control NT 3400 SMIS can maintain cardholder information to card readers and provide programmable levels with respect to selectable time periods and In addition it can monitor fully supervised input and control dry contact output relays as in the following chart 3400 SMIS ACCESS CONTROL CAPACITIES Levels Periods Points Points These capacities are based on use of the ISC control panel 2000 Simplex Time Recorder Co All rights reserved 2 00 control applications can be flexibly implemented connecting the NT 3400 SMIS to the Simplex Intelligent Controller ISC The ISC provides a distributed design featuring a modular backplane archi that supports up to seven different plug in cards each ISC to be configured to meet specific user location requirements Each ISC supports a variety of and reader technologies including Proximity Magnetic Stripe Bar Code Biometric and or Refer to data sheet S3500 0001 for details Security access to the NT 3400 SMIS is accomplished a combination of the features of Microsoft and the NT3400 SMIS software providing following system security capabilities Supported capacity is over 4,000 password operators and over 1,000 operator groupings Action Archiving Operator actions are for review by an authorized administrator Protection In addition to Windows NT and password protection the NT 3400 SMIS two additional layers to optimize system and individualize viewing privileges Precise privileges for execution of each module and within each module can be assigned to each individual Access Restriction Applications and their can be restricted from individuals that do not access to those areas Field Data Security The cardholder can be configured to prevent specific fields from being displayed based on operator privileges and privacy protection requirements Tape Backup An on line tape backup system is to allow archived events database configuration cardholder data to be stored and retrieved The SMIS will display a backup warning request when the archive file reaches a selected level a default 500,000 events can be archived on the hard for retrieval or report generation NT 3400 SMIS provides a true multi user operating system due to its use of Microsoft NT Windows NT allows multiple workstations operators to perform security or database tasks without diminishing system functionality application executed from an NT 3400 SMIS is configured to run in its own memory space speed and application availability between the NT 3400 SMIS are accomplished with industry standard networking and Alarm Management Status Changes and Alarms The NT 3400 provides extensive event and alarm management status changes within the system may be to be alarms or events and alarms provide real time status updates to administrators and operators informed Point status cardholder activity and operator actions are examples that can be defined to report as either an or an alarm status changes are reported the generated event a specific description such as a switch been cut the location of that point such as Door Events can be programmed to generate created in response to either a physical point cardholder activity or by the operator entering a application and Alarm Management by Time System activity be configured to be declared as an alarm or an event on time and day Selections can easily be made to user defined schedules and Alarm Routing The NT 3400 SMIS provides flexibility in how and where events are when they occur As part of the alarm definition the can be configured to route or forward the events alarms to a single destination or multiple destinations destinations include workstations operators and the historical log When an operator is as a destination assigned messages follow the logged on operator throughout the NT3400 network Event or alarm conditions can be routed to different set of NT 3400 SMIS destinations based on of day Priority up to 99 Levels Each alarm generated the NT3400 SMIS can be assigned to one of 99 priority levels with unique colors to assist in the alarm handling process Each alarm can be a specific custom action message so that the is aware of the precise action required when the is displayed After fulfilling the required action an can choose or be required to add an alarm message which is saved to the historical log to the actions that were taken in response to that alarm The operator may choose one or more responses from a prepared list contained in a drop down list box or enter a unique message response to an alarm condition 2000 Simplex Time Recorder Co All rights reserved 2 00 Alarms Alarms can be configured to the computer program or activity being and display the relevant alarm information alarms are configured using a range Whenever an alarm with that priority or is received it is brought to the screen of the Workstation monitor Forwarding As part of the flexible alarm operation an alarm can be defined to at a workstation or with an operator for a specific of time If the alarm is not acknowledged within the time the alarm can be forwarded to alternate such as another group of operators or This provides a backup for high priority that must be addressed immediately such as a or a panic station occurrence Alarm Acknowledgement Priority alarm can require multiple operators to acknowledge alarm before it is cleared from the system Up to nine can be configured for each alarm alarms can be configured to activate a set of points or to call up cameras to pre selected for immediate live viewing of the alarm location NT 3400 SMIS utilizes an industry standard relational which provides extensive flexibility in the design both the content and the presentation of the cardholder on the NT 3400 SMIS Work