Simplex NT 3400 SIMS Version 2 3 with Ethernet 3500 ISC Communication Option

File Preview
File Preview
Click below to download for free

Text Preview

SECURITY 3400 SMIS Version 2.3 Ethernet ISC Communication Option NT 3400 Security Management Information SMIS is a scalable Windows NT based management system designed to a wide range of integrated security Intelligent System Controller ISC Ethernet option allows SMIS File Servers to with ISCs over a standard Local or Wide Network LAN or WAN an existing LAN WAN minimizes the need and of installing new hardwire communication It allows placement of ISCs wherever Ethernet drops exist in a facility even in remote accessible by the facility WAN the initial installation control and administrative of the SMIS are accomplished at the File or security Workstation distributed processing architecture of Intelligent Controllers provides continuous access control making and transaction buffering that enables to function independently if communication with File Server is lost When communication is buffered events are uploaded to the File event log Configuration Ethernet ISC is designed to interface with the 3400 SMIS over a common Ethernet network using standard TCP IP communication protocol Up to 256 can be combined to provide additional access functionality See ISC Capacity table page 5 ISC uses an industry standard 3Com Etherlink Combo card as its Network Interface Card This NIC has proven performance in countless and provides compatibility with 10BASE T 3 4 and 5 twisted pair wiring It operates with broad range of network hubs switches and other components networking connections installation and system can be performed by the same MIS that manages the site existing network 6 00 Modular distributed processing Access Control using up to 256 controllers Can be combined with 4120 Hardwire and Dial up to create a single integrated centrally system performance capacities per ISC Up to 8 card formats Up to 96 input points Up to 48 output points Up to 12 readers Standard up to 5000 cardholder 3000 transactions Expandable to 50,000 cardholder 25,000 transactions Uses standard TCP IP communication protocol Graphical host based diagnostics and attendance Local ISC serial port Port diagnostics LED status indicators for ISC functions Allows parallel simultaneous downloads to up to ISCs 32 bit Intel 386EX embedded processor Flash EPROM allowing software upgrades standard 3Com Ethernet Network Card NIC Battery backup Fused outputs Tamper switch Built in transient protection beige cabinet with locking door 2000 Simplex Time Recorder Co All rights reserved and Performance communication provides several advantages other ISC communication options Ethernet ISC communicates system events to the 3400 File Server as fast or faster than a Simplex hardwire connection without the expense of dedicated wiring It is also significantly faster a Dial up ISC connection over a voice grade line without the expense of providing a telephone or leased line information from the File Server takes at Ethernet network speeds and in parallel to as as 20 Ethernet ISCs simultaneously This results significantly faster initialization and updates to Design addition to three different communication options ISC can be tailored to an individual application by up to six controller expansion cards which in can provide up to 96 input points and up to 48 points The expansion card options include 2 reader module 8 input module 8 output module 16 input module 8 input 8 output module improves system serviceability can troubleshoot and replace individual modules and pluggable terminal blocks allow removal without disturbing wiring connections expansion can be easily accomplished by adding modules to existing ISCs or when an capacity is reached additional ISCs can be to the system Ethernet ISCs can coexist and use the same File Server as 4120 hardwire and ISCs You can choose the combination of ISC that best fit your facility needs to a total of 256 ISCs can be combined and in one NT 3400 system Up to 98 4120 ISCs plus up to 98 Dial up ISCs with the of Ethernet ISCs for a total of up to 256 ISCs ISC has an integral power supply designed to power for the basic ISC electronics and the number of ISC expansion modules 6 This power supply also supports the maximum of card readers specified for each ISC 12 that those readers do not exceed the characteristics Regulated 12 VDC readers 120 mA peak mA average current draw Regulated 5 VDC readers 100 mA average draw Unregulated 10 18 VDC readers 150 mA peak mA average current draw ISC 12 VDC regulated power supply is capable of 1500 mA maximum Certain card readers long range proximity readers and biometric that have greater current draws or other requirements than those of the integral power ratings listed above require separate power Peripheral devices such as electric door electromagnetic locks REX sensors and sounders should be powered by an external supply Backup ISC integral power supply has a battery charging with a battery backup time of 4 hours while the is operated once every five minutes using an Ah battery The battery recharge time is less than 24 hours 24 hour battery backup is available Listings using Ethernet communications have not investigated by UL ISCs using Ethernet may not be used as part of a UL system as they or any other non UL will invalidate the UL Listing on Other SMIS Features and more information on the NT 3400 system and a description of its capabilities refer to data S3400 0007 more information on the ISC and a complete of its capabilities refer to data sheet 2000 Simplex Time Recorder Co All rights reserved 6 00 3400 Version 2.3 and Ethernet ISCs in a LAN WAN Environment ISC ISC ISC ISC ISC ISC 3400 File Server ISC ISC ISC Maximum number of Ethernet ISCs for any NT 3400 system is 256 Maximum number of 4120 ISC nodes is 98 Network Interface Card Specifications that AUI and BNC ports not supported by ISC Application Software Model Number Media Rate Width Draw Etherlink 3C509B Combo Card via RJ 45 connector using CAT 3 4 or 5 twisted pair length 100 meters 328 feet Mbps ISA mA 12 VDC 10BASE T connection 2000 Simplex Time Recorder Co All rights reserved 6 00 ISC MODEL AND COMPONENT SELECTION CHARTS Number Voltage VAC 60 Hz VDC ISC BASIC MODELS Baseline ISC Must choose one Communications Card Baseline ISC Must choose one Communications Card use with external 2081 9307 Power Support System separately see below CARDS FOR ISC Choose one per ISC Number Hardwire Card Modular Card Internal modem NIC to Ethernet ISC choose one or two Media Modules POTS voice grade or dedicated powered line connections LAN WAN connection to the File Server Ethernet NIC and firmware V3.01 for use in UL Listed systems upgrade existing ISC to Ethernet Includes NIC ISC CPU card and firmware for use in UL Listed systems MODULES FOR 4120 MODULAR CARD Number 4120 Media Module Optics Media Module up to two Media Modules as required use with 3500 9805 Number AND I O MODULES Module

Related Files