ULC CSFM Listed Approved System Peripherals or MAPNET II Communicating Devices Manual Stations for Releasing Applications addressable manual fire alarm stations releasing applications with Power and data supplied via IDNet or MAPNET II communications using a single wire pair Operation that complies with ADA requirements Visible LED indicator that flashes during and is on steady when the station has activated Pull lever that protrudes when alarmed Break rod supplied use is optional Dual action push and pull operation Label kit provides for six varieties of releasing ordered separately 4100 4120 and 4020 systems with the following Simplex Releasing control panels equipped with either IDNet MAPNET II communications Model Series 4100ES 4010ES and 4010 construction Electronics module enclosure minimizes dust infiltration Allows mounting in standard electrical boxes Screw terminals for wiring connections resistant reset key lock Locks are keyed the same as Simplex fire alarm cabinets mounting options Surface or semi flush with standard boxes or matching boxes Flush mount adapter kit Adapters are available for retrofitting to commonly existing boxes listed to Standard 38 4099 series addressable manual stations combine familiar Simplex housing with a compact module providing easy installation for applications The integral individual addressable IAM monitors status and communicates changes the connected control panel via MAPNET II or IDNet wiring blank area on the front of the station allows the of a label to match the specific releasing label kit is ordered separately Refer to data S4099 0005 for standard Simplex addressable stations This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing 7150 0026 224 allowable values and or conditions concerning material presented in this document listings may be applicable contact your local Simplex product supplier for the status Listings and approvals under Simplex Time Recorder Co are the property of Safety Products Westminster Addressable Manual Station for Releasing with Manual Release label from Label Kit AGENT DIOXIDE SYSTEM Kit requires that a spring loaded interference marked PUSH be pushed back to access the station lever with a firm downward pull that activates the switch Completing the action breaks an internal break rod visible below the pull lever use is The use of a break rod can be a deterrent to without interfering with the minimum pull needed for easy activation The pull lever into the alarm position and remains extended out the housing to provide a visible indication reset requires the use of a key to reset the station lever and deactivate the alarm switch If break rod is used it must be replaced testing is performed by physical activation of pull lever Electrical testing can be also performed by the station housing to activate the alarm switch 11 2014 Addressable Manual Station Product Selection Manual Stations Double action Push operation Addressable manual station red housing with white letters and white pull requires label kit 4099 9802 kit white lettering on red background select the label required for the specific releasing application include Clean Agent Extinguishing Carbon Dioxide Foam System Sprinkler and Manual mount steel box red Cast aluminum surface mount box red Replacement break rod trim plate for double gang switch box red trim plate for Wiremold box V5744 2 red mount adapter kit black mount adapter kit beige Specifications to page 3 for dimensions for retrofit refer to page 4 to page 4 for details and Communications Means Connections Listed Temperature Range Range Color Lever Color Dimensions Instructions or MAPNET II communications 1 address per station up to 2500 ft 762 m from alarm control panel up to 10,000 ft 3048 m total wiring distance including T Taps 8 position terminal for in out wiring for 18 to 14 AWG wire 0.82 mm2 to 2.08 mm2 to 120 F 0 to 49 C intended for indoor operation to 93 RH at 100 F 38 F with white raised lettering and pull lever are Lexan polycarbonate or equal with red raised lettering H x 3 W x 1 D 127 mm x 95 mm x 25 mm Addressable Manual Station Semi Flush Mounting Gang Box Mount gang box 2 1 2 deep mm RACO 500 or equal by others Square Box Mount 102 mm square box 2 1 8 54 mm minimum RACO 231 or equal supplied by others flush or with 2 mm extension NOT RECESS Square box cover plate DOWN gang cover plate 3 4 mm extension RACO 773 equal supplied by others view Indicator gang outline surface Mount Side View 11 2014 Box separately H x 4 W x 2 3 16 D mm x 102 mm x 56 mm Addressable Manual Stations Surface Mounting Mounting For mounting of these manual stations the electrical boxes are in the illustration to the Mounting Refer to page 4 for box mounting located and bottom Cast Box H x 3 7 8 W x 2 3 16 D mm x 98 mm x 56 mm separately DOWN mm for 3 4 threaded located top and bottom 95 mm 25.4 mm Addressable Manual Station Surface Mount Side View with Internal Detail wiring for reference mm 2975 9178 box for reference setting under label accessible cover open cover open for access mm wiring 11 2014 box V5744 2 by gang switch box each H x 2 W x 2 3 4 D mm x 51 mm x 70 mm by others must be recessed into wall to 1 1 8 25.4 mm to 29 mm Addressable Manual Station Additional Mounting Information retrofit and new additional mounting boxes the required adapter plates shown in the illustration to right Surface trim Wiremold box H x 5 W mm x 127 mm Addressable Manual Station Flush Mounting Information mount adapter kit Black Beige mm cutout must be a of 6 H by 5 W 152 mm by 127 mm Semi flush trim for switch box 6 H x 4 1 2 W mm x 114 mm 121 mm 171 mm View 119 mm box 2 1 8 mm minimum by others View SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited Lexan is a trademark of the General Co Wiremold is a trademark of the Wiremold Company Fire Protection Products Westminster MA 01441 0001 USA 11 2014 2014 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice