Simplex Remote Station Devices, Digital Alarm Communicating Transmitter (DACT) Model 2080-9024
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-remote-station-devices-digital-alarm-communicating-transmitter-dact-model-2080-9024-0865721439.pdf |
---|---|
Type | |
Size | 608.66 KB |
Downloads |
Text Preview
CSFM Listed Accessories Station Devices Digital Alarm Transmitter DACT Model 2080 9024 channel DACT for connection to Simplex alarm control panels without internal DACT Dual telephone line interface with supervised status DACT supervises control panel connections Control panel can supervise the DACT by monitoring contacts Compatible with Simplex fire alarm control panels 24 VDC and Alarm Trouble and contacts UL Listed to Standard 864 per NFPA 72 for Central Service Operation is FCC Part 15 approved to report in the following formats SK 3 1 Sescoa 3 1 SK 4 2 and SK FSK 4 2 Radionics BFSK Contact ID SIA features Programmable power fail report delay Fuseless overload protection with automatic reset Auxiliary relay is programmable to indicate alarm or audible trouble alarm 2080 9024 digital alarm communicating DACT monitor the status of a fire alarm panel and reports alarms troubles and conditions to a central supervising station 24 VDC with battery backup is supplied by the alarm control panel Local AC mains are monitored power loss with trouble reporting programmable with time delay or with a selectable delay of from 6 to 12 Communications Communications to supervising station are via two monitored telephone If one line fails for more than 90 seconds a trouble is transmitted on the other line and an internal alert audio signal will sound If both lines should the internal audio trouble signal will sound a programmable time of day test signal is to the supervising station once every 24 hours Relay Output A SPDT auxiliary relay is with operation programmable to indicated alarm trouble 2080 9024 CHANNEL COMMUNICATOR VOLTAGE PRESENT INSIDE POWER TO THIS BEFORE SERVICING DEVICE BJ 4297 IN USA 121764 DACT Voltage VDC 24 VDC nominal from Fire Alarm Control Current 24 VDC 84 mA Standby mA Alarm Relay Contacts Form C SPDT rated 1 A 24 VDC VAC resistive 2 required Jack Type start Indicators Internal Line Trouble Red one per line W x 10 1 8 H x 3 D mm x 257 mm x 76 mm lbs 2.72 kg This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document It is subject to re examination revision and possible cancellation This was not approved by ULC FM or MEA NYC as of document revision date listings may be applicable contact your local Simplex product supplier for the status Listings and approvals under Simplex Time Recorder Co are the property Tyco Safety Products Westminster 10 2007 Programming 2080 9024 can be programmed for telephone changes time changes loop response time user installer codes account numbers AC mains power reporting time delay and system or zone status is performed by using the optional Remote or by using a PC with software and compatible modem Architect Engineer Specification contractor shall furnish and install an approved communicator transmitter to transmit fire alarm to a central supervising location The shall be UL 864 listed as conforming to the of NFPA 72 for Central Station connections shall be UL listed as compatible with the connected fire alarm control panel 24 VDC operating and battery backup shall be provided by the fire control panel Product Selection communicator transmitter shall have the capability of two telephone lines and of seizing a telephone and sending an alarm signal on one or both lines the need of any additional equipment If service is interrupted on either line for more 90 seconds the communicator transmitter shall be of reporting the loss of either telephone line regard to which line failed If both lines fail a panel mounted trouble alert shall sound communicator shall be capable of being programmed send a test signal to the central supervising location every 24 hours at a user selected time to the central supervising location shall indicate of the communicator transmitter initiating device are in alarm and which are in trouble Restoration normal status shall also be transmitted with specific messages The communicator shall be capable transmitting to Silent Knight Radionics or ADEMCO stations Digital Alarm Communicating Transponder DACT with red cabinet Telephone connection cables two 2 required 7 ft 2.1 m long Annunciator Programmer order category is OPSILENT alphanumeric LCD with key inputs Remote Annunciator Programmer cable to connect to 2080 9024 DACT End of Line Resistor Harness 4.7 k 1 2 W reference 733 896 three 3 required Alarm Trouble and Wiring Reference Diagram relay contacts Form C see note 1 fire alarm 120 VAC to monitor mains status Fire Alarm Panel Locate 20 ft 6 m 2080 9024 wiring in or per local VDC Power 2080 9024 CHANNEL COMMUNICATOR VOLTAGE PRESENT INSIDE POWER TO THIS BEFORE SERVICING DEVICE BJ 4297 IN USA 121764 5230 2080 9031 Line 1 Line 2 RJ31X jacks requires 2080 9022 cables connections to NO contacts each requires 4.7 K end of line resistor harness Auxiliary relay output can be monitored by control panel as Alarm or Trouble Refer to Installation Instructions supplied with DACT for additional mounting and wiring detail Simplex and the Simplex logo are trademarks of Tyco International Services AG or its affiliates in the U S and or other countries NFPA 72 and NFPA are trademarks of National Fire Protection Association NFPA Contact ID is a trademark of Pittway Corporation 2007 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Safety Products Westminster Westminster MA 01441 0001 USA 10 2007