Simplex Retrofit Kits, 4100ES into existing 2120 and 2001 backboxes
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-retrofit-kits-4100es-into-existing-2120-and-2001-backboxes-6452178390.pdf |
---|---|
Type | |
Size | 810.52 KB |
Downloads |
Text Preview
4100ES Fire Control Units Kits for Installing 4100ES Equipment into Existing 2120 2001 and 4100 Series Fire Control Unit Boxes ULC CSFM Listed Approved MEA NYC existing Simplex 2120 2001 or 4100 Series fire alarm control FACU equipment with 4100ES Series products using the existing Retrofit kits include either a solid or glass fronted metal door retainer for glass door applications and box extension hardware Kits are available for one two or three bay 4100ES equipment Colors are available to coordinate with existing beige red or black or to convert to red or beige Beige retrofit kits are a slightly different color from that of the beige boxes Red and black are similar but may not exactly the existing box Consider painting the exposed existing box if coordination is a concern the retrofit kits in place standard 4100ES can be easily installed Existing 2120 or 4100 6 3 4 in depth cabinets accommodate internal mounting up to 33 Ah ref battery 2081 9276 50 Ah or higher sizes require external cabinets Existing 2120 or 2001 6 1 2 in depth cabinets One bay cabinets accommodate up to 18 Ah batteries reference Two or three bay cabinets accommodate up to 33 Ah batteries 2081 9276 larger battery sizes require external battery Established 4100ES module placement rules apply existing backboxes include Solid or louvered boxes in two unit four unit or six unit sizes also as No 2 No 4 or No 6 boxes Shallow boxes that are 6 1 2 in deep used for 2001 Series equipment early 2120 Series equipment Deep boxes that are 6 3 4 in deep used for 4100 Series and for later of 2120 Series equipment Listed to Standard 864 Design Reference When the 4100ES Series of Simplex FACU was developed the cabinet dimensions were optimized to newer generations of equipment design 4100ES cabinets are taller and deeper than those of the 2120 2001 and 4100 products When existing FACUs require capacity or performance it is an opportunity to consider new product solutions When existing Simplex 2120 2001 and 4100 Series equipment 4100ES equipment these retrofit kits allow the update to use the backboxes Retaining the existing boxes allows mechanical and impact to be reduced often significantly 1 application Four unit 2120 retrofitted with two bay 4100ES Applications Examples for these retrofit kits include installed on surfaces that would be costly to modify for marble plaster or concrete or where installed into a custom Whether surface mounted or semi flush mounted these kits can expedite the equipment retrofit process Applications Compatible boxes may be available for retrofit other applications such as some 2100 Series Multiplex equipment determine whether an existing box is compatible with these retrofit see Existing backbox size identification Size Reference 4100ES FACU equipment typically mounts new two or three bay 4100ES boxes Some 4100ES equipment are available for mounting in a single bay size Retrofit are available to convert the 2120 2001 and 4100 two unit or No 2 to accommodate 4100ES single bay equipment Selection Reminder Proper retrofitting of existing requires that the desired fire alarm functions be understood order to specify the necessary 4100ES equipment and 4100ES Equipment compatibility BMUX The Head End of a 2120 Multiplex System is called the It communicates with a variety of 2120 compatible transponders perform the majority of the fire alarm functions 4100ES equipment be equipped with a dual RS 232 Module 4100 9038 that is for one channel to communicate to a 2120 BMUX as a Transponder 4100ES Equipment Communications with a 2120 BMUX available with 4100ES Series FACUs MINIPLEX Transponders and Display Units NDUs as Head End You need to replace or upgrade existing to be 4100ES compatible for applications where the 4100ES is required to become the Head End control product has been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 7165 0026 251 for allowable values conditions concerning material presented in this document It is subject to re examination revision and possible cancellation This product was not approved by MEA NYC as of document date Additional listings may be applicable contact your local Simplex product supplier for the latest status Listings and approvals under Simplex Time Recorder Co are the property of Tyco Products Westminster Rev 8 11 2019 2120 2001 4100 Standard 4100ES4 Unit Equipment Boxtwo bay box outline4100ES Equipment mounts with two bay Retrofit Kit sized to fit existing boxExisting equipment is removed Solid door 2120 4100 Transponder shown for reference firealarmresources com Kits for Installing 4100ES Equipment into Existing 2120 2001 and 4100 Series Fire Alarm Control Unit Boxes backbox size identification designation unit No 2 unit No 4 unit No 6 Figure 2 and Figure 3 for additional dimension reference height 3 4 in 527 mm 1 4 in 921 mm 1 8 in 1324 mm Existing backbox identification reference dimension width box depth box depth 3 4 in 654 mm 1 2 in 165 mm 3 4 in 171 mm If the holes indicated are not present at each corner drilling will be required For more information refer to 4100U System Installation to and 2100 2120 Back Boxes 579 766 2 box dimensions Conditions of the existing enclosure may require enlarging some of the mounting holes to facilitate kit installation 3 box dimensions 2 Rev 8 11 2019 1 2 in deep 165 mm 1 3 4 in 44 mm 1 3 4 in 44 mm Shallow box dimensions typical of 2001 Style and older 2120 Style6 3 4 in deep 171 mm 5 8 in 16 mm 1 2 in 13 mm Deep box dimensions typical of newer 2120 Style and 4100 Stylefirealarmresources com Kits for Installing 4100ES Equipment into Existing 2120 2001 and 4100 Series Fire Alarm Control Unit Boxes and 2001 style shallow backbox retrofit kit selection for existing 2120 or 2001 style boxes with box depth of 6 1 2 in or 165 mm and with front top lip of 1 3 4 in or 44 mm kit information model size bay bay bay bay bay bay bay bay bay bay bay bay bay bay bay bay bay bay backbox reference reference Series Series Series Series louvered Series Series louvered Series Series louvered Series Series louvered Series Series Series louvered Series Series louvered Series Series Series louvered Series Series louvered Series Series Series Series louvered Series Series louvered Series Series louvered Series Series louvered Series Series Series louvered Series Series louvered Series Series Series louvered Series Series louvered The terms two unit four unit and six unit are used interchangeably with No 2 No 4 and No 6 For semi flush trim kits use 2975 9801 Beige and 2975 9802 Red unit unit unit unit unit unit unit unit unit unit unit unit unit unit unit unit unit unit 3 Rev 8 11 2019 Kits for Installing 4100ES Equipment into Existing 2120 2001 and 4100 Series Fire Alarm Control Unit Boxes and 4100 style deep backbox retrofit kit selection for existing 2120 and 4100 style boxes with box depth of 6 3 4 in or 171 mm and with front top lip