Simplex S4098-0036-6 7 11 VLC-600 VLC-600 TrueAlarm LaserCOMPACT Smoke Sensor with 4100ES 4100U 4010ES IDNet™ and MAPNET II Communications

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed Analog Sensing TrueAlarm LaserCOMPACT Smoke Sensor with IDNet and MAPNET II Communications VLC 600 addressable analog output air smoke sensor provides VESDA LaserCOMPACT operation communicating the established TrueAlarm analog sensing process area coverage up to 8000 ft2 Compact 8 7 8 225 mm square size Dual stage dust filter that is used on larger systems Obscuration measurements communicated to the fire control panel for status determination Panel selected sensitivity from 0.016 ft to 4.08 ft Local computer port access for the VESDA Vconfig software program as used on larger systems Single LED that indicates local status information Capability of driving a remote LED ordered conditions are also communicated Mechanical problems are received as sensor troubles Electrical problems are received as answer troubles Additional details are indicated by the sensor LED and accessing sensor diagnostics with Simplex 4100ES 4100U or legacy 4100 4120 fire alarm control Communications via 4100ES 4100U 4010ES IDNet 4100ES 4100U MAPNET II addressable formats Connection is to the same SLC signaling line circuit other devices such as addressable manual TrueAlarm area smoke sensors addressable modules etc Communications are as a single device and connection is to the SLC without requiring a dedicated interface 4100 4120 requires revision 8.01 or higher software threshold levels are programmable from the alarm control panel with typical selections as Stage 1 Alert at 0.016 to 0.6218 obscuration ft Stage 2 Pre Alarm at 0.03 to 0.6234 obscuration ft Stage 3 Alarm at 0.05 to 4.08 obscuration ft NOTE UL listed evacuation alarm sensitivity is not be less sensitive than 0.625 ft pipe network Uses standard Vision Systems pipe and inlet in with Vision Systems Aspire design tool listed to Standard 268 URXG This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document It is subject to re examination revision and possible cancellation This was not approved by FM or MEA NYC as of document revision date Additional may be applicable contact your local Simplex product supplier for the latest status and approvals under Simplex Time Recorder Co are the property of LP Westminster air inlet room cable tray LED indicator COMPACT ARM 600 TrueAlarm Air Smoke Sensor manual stations sensors and other devices DOWN IDNet 4100ES 4100U MAPNET II communications VDC power ROOM DETECTOR Alarm Control Panel requires 4100ES 4100U 4010ES IDNet 4100ES 4100U MAPNET II Communications shown for reference LaserCOMPACT System Connections aspiration technology smoke detection operates actively drawing in air for sampling in a high intensity detection chamber The Model VLC 600 LaserCOMPACT smoke detector uses the in VESDA sampling technology including a highly laser light source and a dual stage dust filter analog sensing occurs when the LaserCOMPACT sensor communicates chamber information to the connected fire alarm panel The panel evaluates the smoke sensor against three programmed thresholds and an alarm or pre alarm condition depending on chamber activity communications In addition to smoke information the TrueAlarm LaserCOMPACT advises the fire alarm control panel of local trouble Troubles may include dirty filter airflow or failure etc Specific details are stored in at the sensor location Continued logging The sensor status history for all alarms and fault events is monitored and logged with and date stamps within the electronics of the sensor via the local computer port General trouble indications are communicated to the panel as either troubles or answer troubles Information to Installation Instructions 19772 shipped with the for additional information air flow A high efficiency aspirator draws air through a simple pipe network to a detector Air entering the sensor housing passes a sensor before the sample is passed through a dust filter The majority of air is exhausted the detector and where required back vented to the area The first stage of the air filter removes and dirt from the air sample before it enters the detection chamber A second ultra fine filter stage a clean air supply to be used inside the detection to form clean air barriers which protect the surfaces from contamination detection chamber The detection chamber uses stable highly efficient laser light source and unique configuration to achieve optimum response to a wide of smoke types When smoke passes through the chamber it creates light scattering which is by very sensitive sensor circuitry The analog level the sensor is then communicated to the fire alarm control for comparison to pre selected alarm thresholds Product Selection LaserCOMPACT Smoke Sensor sampling pipe is ordered separately Red LED Status Indicator on single gang stainless steel plate requires a single gang box 1 1 2 minimum depth connections are color coded wire leads Specifications Voltage Current to 30 VDC supplied from fire alarm control panel mA 24 VDC supervisory and alarm IDNet or MAPNET II addressable automatically selected One address one unit load per sensor Terminations blocks for 18 to 12 AWG Conditions Air F to 140 F 20 C to 60 C Ambient 14 F to 103 F 10 C to 39 C Humidity 10 95 RH non condensing Network area of coverage 8000 ft2 maximum pipe length in with Vision Systems computer design tool ASPIRE and standards Listed Velocity Range to 4000 ft min 0 to 1200 m min Sensitivity Range Sensitivity Levels Service Access Rating to 4.08 ft obscuration selected at the fire alarm control panel UL listed evacuation alarm sensitivity is not to be less sensitive 0.625 ft levels selectable and designated as required at the fire alarm panel DB 9 RS 232 connection for a service computer using VESDA Pro software program authorized service access only 1 IP 30 lbs 1.9 kg LED Status Indications off or active sensor is waiting for panel communications for approximately 3 seconds up self test due to sensor being in reset cycle Steady condition as commanded from panel pulse approximately every 4 seconds operation pulse indicates communications with panel pulses 2 Hz rate every 2 seconds fault not communicating with panel sensor needs internal service or replacement Mounting Information mm 8 7 8 225 mm 3 3 8 85 mm LED indicatorAir exhaust location rear assembly can be rotated 180 to reverse intakeand exhaust locations and knockout locations Air intake locationSide knockouts 2 Top knockout locationRear knockoutlocationMountingbracketfirealarmresources com is a registered trademark of Tyco International Services GmbH and is used under license Simplex the Simplex logo TrueAlarm MAPNET II and IDNet are trademarks of International Ltd and its affiliates and are used under license VESDA LaserCOMPACT and ASPIRE are trademarks of and or property of Xtralis Pty Ltd LP Westminster Westminster MA 01441 0001 USA 2011 Tyco All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice

Related Files