Simplex Serial (LED) Annunciator Cabinet 5 97
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-serial-led-annunciator-cabinet-5-97-4538062791.pdf |
---|---|
Type | |
Size | 615.71 KB |
Downloads |
Text Preview
Multi Application Peripherals Accessories Series LED Annunciator Panels Listed Approved Allows Multiple SCU RCU Configurations Information is Transmitted Over a Single Shielded Pair Supervised from Simplex Control Panel LED Test Feature Key Controlled Functions Switches Pluggable LEDs Allow Status Type Surface or Flush Mounted Beige Finish with Black Trim Optional Stainless Steel Trim Flush Mount 24 VDC Nominal System Supplied Supervisory Current 24 mA Alarm Current 55 mA Supervisory Current 32 mA Alarm Current 80 mA 18 H x 14 W x 3 1 2 D mm x 356 mm x 89 mm Trim 18 7 32 H x 14 7 16 W mm x 367 mm Trim 20 H x 16 W mm x 406 mm fire alarm system information is required to be remote from the main control panel this annunciator provides the capability of up to four 4602 series LED annunciators one cabinet Annunciator types include the Command Unit and the Remote Command and trouble information is transmitted from the panel to the annunciator via a single twisted pair Power is supplied using a separate 1 5 2 6 3 7 4 8 1 5 9 13 2 6 10 14 3 7 11 15 4 8 12 16 1 5 9 13 2 6 10 14 3 7 11 15 4 8 12 16 1 5 9 13 2 6 10 14 3 7 11 15 4 8 12 16 ANNUNCIATOR TRIM WITH RCU 3 SCUs COMMAND UNIT 4602 6001 4602 Status Command Unit SCU provides LEDs per unit An LED test switch is COMMAND UNIT 4602 7001 4602 Remote Command Unit RCU provides LEDs four switches a common trouble circuit a power on indicator RCU control switches duplicate the switch operation of the fire control panel If desired these switches can custom programmed for site specific functions switches are enabled by a key switch that is in the enabled position control switch functions include Silence Alarm Silence System Reset and Evacuation common trouble circuit consists of an Audible tone alert and a Visible Indication Yellow 1996 Simplex Time Recorder Co S4602 0004 5E 4 96 page 1 of 2 SERIES ANNUNCIATOR PANEL FEATURE SELECTION IDENTIFICATION Annunciator Panel Includes Cabinet Provides Space up to 4 4602 7001 6001 Modules The standard 4602 8001 is for Surface Mount only not field convertible a Flush Trim if flush mounting required Command Unit RCU Command Unit SCU Panel Without SCU or RCU Trim Stainless Steel Trim Beige Only Order if Required for WIRING TO INSTALLATION INSTRUCTIONS FA4 21 256 ADDITIONAL INFORMATION 2 18 TO 12 AWG Fire Alarm Panel DATA BUS SINGLE 18 AWG SHIELDED PAIR 1 5 2 6 3 7 4 8 1 5 9 13 2 6 10 14 3 7 11 15 4 8 12 16 1 5 9 13 2 6 10 14 3 7 11 15 4 8 12 16 1 5 9 13 2 6 10 14 3 7 11 15 4 8 12 16 S4602 0004 5E 4 96 page 2 of 2 Massachusetts 01441 0001 U S A and Representatives Throughout the World visit our homepage specifications and other information shown were current as of printing and are subject to change without notice