Simplex Series 600 Smoke Detectors; High Performance Optical Smoke Detectors
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-series-600-smoke-detectors-high-performance-optical-smoke-detectors-7810692534.pdf |
---|---|
Type | |
Size | 693.37 KB |
Downloads |
Text Preview
Listed 600 High Performance Optical Smoke details Superior performance and reliability Attractive new design Designed for fast and easy installation Unique position for commissioning and service seamlessly with a wide range of panels Compatible with Tyco 600 Series for easy upgrade Low operating current up to 32 detectors per zone Dual sensor optical and heat Optional remote alarm indicating LED Low profile discrete and unobtrusive Designed for EMI compatibility UL listed to Standard 268 available in two sensitivity settings 601PH UL Standard Sensitivity nominal 2.11 to obscuration 601PH UL L Special Application Sensitivity nominal to 3.8 ft obscuration chamber enclosure Concentric baffle design enhances smoke capture by air flow to the smoke chamber High Performance Optical HPO detector uses a measuring system Unlike most other optical detectors the HPO does not use vertical chevrons exclude ambient light but uses concentric baffles This gives a better signal to noise ratio and allows the to be used in its high sensitivity enhanced mode detectors react to the whole range of fire products slow smoldering fires producing visible particles to flaming fires producing large numbers of very hot sized aerosols It combines optical and heat technology to detect clear burning fire products previously could only be easily detected by technology detectors For normal ambient the high performance optical detector behaves a normal optical detector Only when a rapid rise in is detected does the sensitivity of the detector and the presence of smoke will confirm a fire The HPO will not operate on a rate of rise of alone 600 Smoke Detectors Series 600 High Performance Optical Detectors for Two Wire Bases High Performance Optical Smoke Detector in 5B Base with 6A 5B UL Adapter 600 Detector Features HPO detector has been designed to offer improved of such fires by detecting the rapid Rate of Rise air temperature and under these conditions increasing smoke detection sensitivity This gives an earlier of such fires and a broader detection capability a standard sensor HPO detector has two sensing systems as follows An optical chamber with associated electronics to the presence of smoke by light scatter A thermistor bridge with its associated electronics to the presence of hot air currents Reference Locations see table on page 4 Locations be determined only after careful consideration of physical layout and contents of the area to be Refer to NFPA 72 the National Fire Alarm On smooth ceilings smoke detector spacing of ft 9.1 m may be used as a guide Selection The 601PH UL standard detector is recommended for most applications a special application for reduced sensitivity is required the 601 PH UL L should be Consult your local Simplex product supplier assistance in determining the proper selection Refer to page 2 for additional listing information This product was not ULC or CSFM or approved by FM or MEA NYC as of document revision date Additional listings be applicable contact your local Simplex product supplier for the latest status Listings approvals under Simplex Time Recorder Co are the property of Tyco Safety Products 3 2009 Performance Smoke Detector Compatible with 5B base 5 127 mm diameter Product Selection to 3.8 ft to 3.8 ft Bases Base with connections Remote Alarm LED Accessories 152 mm Base Adapter Protective Cage Shorting Adapter Detector Status LED Indicators Indication approximately every 10 seconds On Dimensions and Reference Information and LED connections are screw for input output wiring 18 to AWG 1 mm2 to 1.5 mm2 Reference listed under Thorn Security LTD the 5B surface area protective cage for Series 600 using the 5B base tool shorts out base to enable cable resistance to be carried out Reference listed under Thorn Security LTD listed not applicable service tool only Detector Cage 3 2009 Mounting Information Specifications Current Current Temperature Range Temperature Range Range base base with base adapter to 33 VDC from fire alarm control panel IDC 24 VDC to 68 mA maximum exact current is determined by alarm current of connected IDC F to 176 F 25 C to 80 C F to 100 F 0 C to 38 C to 95 non condensing 019 Dia x 2 1 8 H 127 mm x 55 mm Dia x 2 9 16 H 152 mm x 66 mm 3 2009 Application of 600 Series Detectors table below is for guidelines only specific situations are likely to require variations on the suggested detector types Real may require detector combinations to cover all likely risks Very clean dry moderately regulated smoky and or Example room light hospitals bay diesel etc ferry deck pen laundry room test Loading electric cable clothes furnishings cardboard foams bedding shavings liquids solvents gasses general waste fodder structures fuels chemicals materials contents Risk pyrolosis fumes arcs source electrical difficult locate toxic likelihood of back fire rapid of dense high fumes explosion and flame fairly slow but temperatures established of fire risk may as can the type fire may require a of detection is a registered trademark of Tyco International Services GmbH and is used under license Simplex and the Simplex logo are trademarks of Tyco International Ltd and its and are used under license NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA 2009 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Safety Products Westminster Westminster MA 01441 0001 USA 3 2009