Simplex SX501 Addressable Outdoor Call Point with Isolator [INTERNATIONAL USE ONLY]
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-sx501-addressable-outdoor-call-point-with-isolator-international-use-only-9402378651.pdf |
---|---|
Type | |
Size | 985.03 KB |
Downloads |
Text Preview
Outdoor Isolated Callpoint here to activate LED Outdoor Isolated Callpoint is an addressable weatherproof manual callpoint signals the condition of a switch contact that is operated by on a deformable element After activation the deformable element not destroyed and the callpoint can be reset unit features a short circuit isolator and meets the requirements of Pt 11 and EN54 Pt 17 of the Status LED and activation are on Page 2 mm Fixing Holes Places Number box lock here similar Isolator Outdoor element pack of 1 Installation the back box not pictured This is supplied with cable entry holes with screw in blanking plugs Choose appropriate cable entry and remove the plugs The holes must be at the top and bottom the back box once mounted Screw plugs into the unused entry holes complete with the provided washers For maximum sealing around the pugs apply a thread such as Loctite 5331 appropriate glands to the entry holes Choose glands that fit the holes 20 mm diameter and provide a good seal round the loop required fit the metal earthing plate This may be required to maintain continuity across conduit sections for example The plate fits the rear of the back box and angles around to the top and bottom of back box where it features holes corresponding to the cable access The plate is held in place by the fittings made to the cable access Mount the back box to the wall using the supplied screws Mount the with the cable entry hole at the bottom for best weatherproofing the loop wires into the back box through the access holes necessary make connections to the back box earth terminal You connect the loop left and right screens to this to maintain continu Remove the connector from its socket and connect the loop into it Now start to work with the callpoint itself Connect an 801AP MX Tool or an 850EMT into the programming port noting the ori Program the unit with the ID defined in the site configuration Ensure the rubber gasket is correctly seated in the channel on the rear the callpoint Align the callpoint to the back box and insert the push fit connector Place the callpoint squarely over the back box and carefully push it into until the locating clips engage Insert the four back box locking screws version 1.0 Operation Maintenance Compatibility Temperature Temperature Outdoor Isolated Callpoint check the status LED is shown on the previous page its conditions are this is normal yellow there is a short circuit on loop This must be rectified as quickly as possible red the has been activated indicating that there is a fire alarm state within building activate activate the callpoint press on the position marked large dot This a spring to push the plastic element downwards so closing a switch triggering a signal to the control panel test test reset key is provided to activate the callpoint for testing Insert this the slot in the bottom of the unit and pull the sliding plate lower half the front face downwards Note this potentially causes an alarm the key deformable element also allows you to test by activating the callpoint normal This is non destructive reset reset the callpoint follow the test procedure above the plate downwards allows the element to snap back to its non state replace the glass or deformable element the test procedure above Pull down further on the sliding plate it is free of the unit Remove the deformable element pulling away bottom first Fit the replacement then push the sliding plate upwards it snaps back into place remove the unit from the backbox Remove the back box locking screws Gently lever the callpoint away from the back box by twisting a flat screwdriver in the slots between them only with the Simplex SX501 Fire Controller applications to 70 oC to 70 oC Retardant ABS glass reinforced Humidity to 95 non condensing HWD x 97.5 x 73 mm g Rating of Performance Approval Type Approvals required Declarations and certificates are publicly available on the website www simplex fire com and are searchable by number or model name above fire detection products are components designed for use in Addressable Systems exclusively available to registered partners only They are intended for installation trained registered personnel only Systems should be installed and configured according to local regulations doc version 1.0 9 April 2018 Johnson Controls All rights reserved All specifications and other information shown were current as of revision date and are subject to change without notice Fire Security GmbH Victor von Bruns Strasse 21 8212 Neuhausen am Rheinfall Switzerland