Simplex SX501 Addressable Sensors [INTERNATIONAL USE ONLY]
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-sx501-addressable-sensors-international-use-only-5408167329.pdf |
---|---|
Type | |
Size | 686.65 KB |
Downloads |
Text Preview
Addressable Sensors Addressable Sensors are for use in an addressable system using MX Digital Protocol where sensors are placed in key areas around building The sensor measures environmental parameters and the values to the fire alarm control panel The control panel incoming data to decide if an alarm needs to be issued on the model environmental variables monitored are one a combination of Temperature Smoke Density Concentration of Carbon monoxide CO used either in Toxic Gas or Fire Detection mode not both Heat Sensor Sensor Sensor Number and Base compatibility Monitoring The sensors are able to identify the following faults Heat temperature sensor A normal output level is expected around temperature CO sensor The integrity of the sensor cell is monitored Optical smoke sensors The optical chamber is periodically stimulated testing Fire conditions are artificially simulated in the detector to prompt a fire response indicator The status indicator has 3 states Yellow flashing a sensor fault Red flashing normal operation flashes on detector poll This can be enabled disabled using the panel configuration software Red continuous the sensor is in alarm LED The sensors are capable of driving a Remote LED Programming By docking the sensor into an 801AP MX Service Tool or an 850EMT you can programme the sensor address Addressable Sensors are installed by fitting into a specially designed base Features of the base are Detector Locking The locking pin prevents unauthorised removal of the detector head Lock release A suitable tool is inserted into the access hole on the detector cover to release the locking pin Park Position Securely holds the detector in the base without making electrical contact a detector Position the detector marker approximately 15mm 15 anticlockwise from the base marker Rotate the detector to mate it to the base Ensure the detector rib and base rib are aligned with each other and connect base wires according to instructions supplied with the base the raised rib alignment markers on the edges of the detector and base version 1.0 Table following table shows the features functions and characteristics of the models in this product series Name Addressable Sensors with Isolator optical Monitoring Indicator LED Base Compatibility Circuit Line Isolator Programming Continuity Base Toxic Gas Mode Compensation Logic with Standard Base temperature temperature humidity Rating to 70 to 80 to 70 to 80 to 70 to 80 non condensing 42 mm Diameter 108 mm cover and closure White flame Retardant ABS use in an addressable system with MX Digital Protocol not expose to direct sunlight in accordance with BS EN 60529 1992 A2 2013 NUMBER of Performance Heat Sensor Sensor APPROVAL required Declarations and certificates are publically available on the website www simplex fire com and are searchable by number or model name above fire detection products are components designed for use in Addressable Systems exclusively available to registered partners only They are intended for installation trained registered personnel only Systems should be installed and configured according to local regulations doc version 1.0 29 June 2018 2018 Johnson Controls All rights reserved All specifications and other information shown were current as of revision date and are subject to change without notice Fire Security GmbH Victor von Bruns Strasse 21 8212 Neuhausen am Rheinfall Switzerland