Simplex System Accessories Battery Brackets for Seismic Activity Applications
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-system-accessories-battery-brackets-for-seismic-activity-applications-4731956280.pdf |
---|---|
Type | |
Size | 747.68 KB |
Downloads |
Text Preview
Accessories Brackets for Seismic Activity Applications secured battery mounting for areas where seismic activity is Available for use with compatible Simplex fire alarm panel Model Series 4100ES 4010ES 4100U 4005 4009 IDNet NAC Extender 4009A Addressable Controller 4009T and Available for use with EZCare 2 bay cabinet with Ethernet Switches and related Design was laboratory shake table tested and certified resist the maximum considered earthquake in the States on site to either surface mount or flush mount see installation reference below One bracket holds two 2 compatible batteries Galvanized steel construction with insulation near terminals Refer to page 2 for selection information For additional information on seismically compliant under the State of California Statewide Office Housing and Development OSHPD Special Seismic SSC program guidelines refer to Seismic Guide 579 1213 the following requirements 2012 International Building Code CBC 2013 California Building Code ASCE 7 categories A F and all building heights Battery Mounting For geographic regions earthquake activity is a building design criteria battery brackets will hold the system batteries in place Tested Independent laboratory testing was to ensure these battery brackets meet the of ASCE 7 categories A through F per the Ss 3.73 G Sds 2.5 G z h 1.0 2012 and CBC 2013 Certified AC156 Testing Standard Factor 1.5 the highest category Bracket Shown in a 2 Bay 4100ES Cabinet Reference Install bracket hardware into flush boxes before box installation for easier Always mount boxes solidly Align mounting with wall studs Refer to the product box instructions for additional information For additional battery bracket installation refer to Installation Instructions This product was not agency listed as of document revision date 6 2015 4010ES 4007ES 4009TPS 4009 IDNet Extender 4009A Addressable 4009T 4007ES 4010ES 4005 4005 systems with require 4005 9860 per below 4010ES 4100U EZCare 2 Bay with Ethernet Switches related equipment Requires 5009 9906 Kit per below and 4100U 2 or 3 Bay Cabinet 1 or 2 bay and 4100U Bay Cabinet Only Requires use of Battery Shelf separately per below Battery Bracket Selection Reference No Batteries V sealed lead acid Compatible Products Dimension Reference Dimensions 1.5 mm Thick 12.7 Ah W x 4 D x 4 H mm x 102 mm x 102 mm mm mm Ah W x 3 3 8 D x 6 5 8 H mm x 86 mm x 168 mm mm mm Ah W x 5 D x 7 H mm x 127 mm x 178 mm mm mm Ah W x 5 1 4 D x 6 3 4 H mm x 133 mm x 171 mm mm 167 mm Ah W x 5 1 2 D x 8 7 8 H mm x 140 mm x 225 mm mm mm Note These brackets mount two of these 12 VDC batteries wired in series for 24 VDC systems Refer to data sheet S2081 0006 additional battery information Alternate batteries must be of identical dimensions Battery Equipment Battery Shelf required when using 50 Ah batteries in 4100ES and 4100U cabinets Retrofit DACT Bracket required when adding the 2081 9401 battery bracket to a 4005 Series Fire Alarm Control mount supplied DACT on this bracket for seismic rated mounting Bracket will become standard production during 2012 identify by metal snap connections replaced with for screw connections Rated Screw Kit required for the 5009 9724 cabinet assembly use one kit per Ethernet Switch Screws will become standard production during 2012 identify as nylon screws with steel core SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited 2015 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Fire Protection Products Westminster MA 01441 0001 USA 6 2015