Simplex System Accessories, LCD Annunciators 4606-9101 LCD Annunciator for 4010, 4006, and 4008 Fire Alarm Control Panels

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed FM Approved NYC Acceptance Accessories LCD Annunciators 4606 9101 LCD Annunciator for 4010 and 4008 Fire Alarm Control Panels LCD annunciator for use with Simplex 4010 4006 and 4008 fire alarm control readout provides Two lines of 40 characters each Wide viewing angle super twist design LED backlighting switches and status LEDs for Alarm supervisory or trouble acknowledge access controlled Alarm silence System reset programmable LED indicators Two LEDs are selectable as red or yellow One LED is selectable as green or yellow With provisions for custom labeling features is transmitted over a single twisted pair separate wiring is required for 24 VDC panel power Tone alert sounder provides local audible indication Lamp and LCD are functionally tested each time the is turned on Mounts flush on standard 6 gang electrical box and trim options Surface mount box model 2975 9206 ordered see additional information on page 3 Brushed stainless steel trim model 4603 9111 ordered Annunciation 4606 9101 LCD Annunciators compatible fire alarm control panels to provide and control switches at convenient locations from the control panel The LCD is an 80 character alphanumeric display with information presented clear and descriptive English Typical content includes status alarm trouble etc alarm type smoke manual station etc number of system alarms conditions troubles and custom location up to 40 characters long Some 4006 4008 are limited to 20 characters refer to the control documentation for additional information LCD Annunciator Continued Data communications require a twisted shielded pair that supports other on the same communications channel 4010 Series panels control up to six annunciators 4006 and 4008 Series panels control up to four Alarm Supervisory and Trouble are also indicated by dedicated LEDs and a audible indication Each condition has a acknowledge push button switch that silences tone alert but leaves the LED on until all conditions in category are restored to normal Scrolling Repeated operation of the acknowledge switch will scroll the LCD showing activity in the sequence of occurrence internal tone alert also sounds to indicate the of any of the push button switches Access All switches on the annunciator are by the keyswitch with a key that is only in the disabled position Operations When enabled notification can be deactivated by pressing the switch Pressing the RESET restores the system to normal operation When activity is normal the LCD displays the time and IS NORMAL This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document It is subject to re examination revision and possible cancellation Accepted use City of New York Department of Buildings MEA35 93E Additional listings may applicable contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Fire Protection 8 2016 Product Selection Remote LCD Annunciator with beige trim Brushed stainless steel trim option Matching surface mount box ivory finish Overvoltage protector required where annunciator communications and power wiring exits and enters a matching resistor harness 100 1 2 W reference no 733 974 to specifications on page 3 additional details refer to data sheet S2081 0016 for details 4606 9101 Operator Information X 40 LCD READOUT green LED during normal conditions abnormal operating conditions PROGRAMMABLE Yellow each with custom labeling pocket STATUS INDICATOR LEDs provide system status in addition to LCD information LEDs flash to the condition and then when acknowledged on steady until reset Fire Alarm is red System System Trouble and Alarm Silenced are Power On is green ACK FIRE ALARM acknowledges Fire Alarm condition and silences the and all annunciator tone alerts ACK acknowledges System conditions and silences the and all annunciator tone alerts RESET restores panel to normal all alarmed inputs returned to normal ENABLE all switch functions is removable only in position ACK acknowledges Troubles and silences the and all annunciator tone alerts SILENCE causes audible and notification appliances to be default operation may be through panel programming for with local requirements 8 2016 4606 9101 LCD Annunciator Specifications Operating Specifications refer to Installation Instructions 579 978 for additional information Operating Current to 32 VDC system supplied mA with LED backlighting on mA during battery backup LED backlighting is turned off after 30 seconds switch activity mA maximum LED backlighting is on and tone alert is sounding to 120 F 0 to 49 C to 93 RH non condensing at 100 F 38 C Standby Current Current Temperature Range Humidity Range 4010 Panels 4006 4008 N2 external annunciator communications line Up to 6 annunciator modules total 4606 9101 or 4605 series 24 point I O modules N2 communications format but with different capacity Up to 4 annunciator modules total compatible with 4606 9101 4610 9111 and mounted LED annunciator Single twisted shielded pair 18 AWG 0.82 mm2 and Earth 18 to 12 AWG 0.82 mm2 to 3.31 mm2 wires for 24 VDC system power and Earth for electrical box ground per local code wiring Up to 4000 ft 1219 m 0.58 580 nF maximum capacitance 35 maximum wiring Up to 10,000 ft 3048 m total wiring up to 2500 ft 762 m to farthest device Matching wiring Connect one at panel and one at end of line wiring Connect one at panel and one at farthest device 1 2 W PID 4081 9011 number 733 974 Information Dimensions Depth Trim Finish Optional Trim H x 11 13 W 114 mm x 300 mm 5 33 mm 1 at terminal block location 38 mm painted beige stainless steel ordered separately supplied with both slotted and tamper screws boxes Six gang box Steel City GW 635 G 3 89 mm deep or equal gang boxes Six single gang boxes 3 89 mm deep minimum RACO 590 or equal selection note Conduit entrance is box dependent refer to additional mounting information on 4 and Installation Instructions 579 978 for by Surface Mount Box Option ordered separately 31 W x 4 H x 2 D 304 mm x 117 mm x 70 mm steel ivory finish Refer to control panel data sheets S4010 0001 S4006 0001 and S4008 0001 for additional information 8 2016 Mounting Information Review box choice with assembly layout before selecting conduit location to allow easy access to terminals Mount Ganged Boxes 6 gang box 3 1 2 89 mm min use 6 RACO 590 or equal separately Mount Masonry Box Steel City GW 635 G or equal 3 1 2 mm deep or equal supplied Mount Box model 2975 9206 deep 70 mm separately Annunciator Assembly plate block at rear of

Related Files