Simplex System Accessories; LCD Annunciators, Model 4603-9101
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-system-accessories-lcd-annunciators-model-4603-9101-9847526031.pdf |
---|---|
Type | |
Size | 903.31 KB |
Downloads |
Text Preview
ULC Listed FM CSFM MEA NYC Approved Accessories LCD Annunciators 4603 9101 LCD Annunciator for and 4100U Fire Alarm Control Panels LCD annunciator for use with Simplex 4100ES and 4100U fire alarm control panels Legacy products 4100 4120 and 4020 fire alarm control and 4100 4120 Universal Transponders display features Maintained display of first alarm is available with and with 4100U at software revision 11.11 or Wide viewing angle super twist LCD technology with LED backlighting Two lines of 40 characters each LED status indicators During battery backup backlighting is disabled until is switch activity include Switches for system acknowledge alarm silence and reset Four programmable control switches Lamp LCD test information RUI Remote Unit Interface communications require a twisted wire pair see p 3 for more information Separate wiring is required for 24 VDC control panel mount on standard electrical boxes 2975 9206 Surface mount box 4603 9111 Brushed stainless steel trim Listed to Standard 864 Remote Control and Annunciation is provided using 80 character back lit alphanumeric display is presented in clear descriptive English and includes Point Status alarm trouble etc Type smoke detector manual station etc of System Alarms Supervisory Conditions Trouble Conditions and a Custom Location Label A single twisted wire pair provides serial RUI that also supports other Simplex serial on the same wire pair Indications Alarm Supervisory and Trouble are also indicated by dedicated LEDs and a audible sounder Each condition has a dedicated push button switch that silences the but leaves the LED on until all conditions in category are restored to normal Switch operation is globally or individually acknowledgeable by the control panel operation LCD Annunciator Continued operation of the appropriate acknowledge will scroll the LCD display showing activity in the of occurrence The tone alert also pulses to the operation of any of the push button switches local code requirements for guidance in applications and location of the 4603 9101 annunciator System Controls Notification appliances can be by pressing the SILENCE switch operation is determined by the host control panel as visible appliances remaining on until system is Pressing the RESET switch restores system to normal operation When system activity is the LCD displays the time date and NORMAL Switches Four programmable and associated LEDs are included Typical include manual evacuation door holder bypass and elevator capture bypass Enable All switches on the annunciator are by the keyswitch with a key that is only in the disabled position A brief test is performed whenever the keyswitch is from enabled to disabled Backup Operation During battery backup LED backlighting is disabled to conserve battery When an annunciator switch is activated the is automatically enabled After 30 seconds of inactivity the backlighting again be disabled This product has been approved by the California State Fire Marshal CSFM pursuant to 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in document It is subject to re examination revision and possible cancellation for use City of New York Department of Buildings MEA35 93E Additional may be applicable contact your local Simplex product supplier for the latest Listings and approvals under Simplex Time Recorder Co are the property of Tyco Protection Products 8 2016 Product Selection LCD Annunciator with beige trim Remote LCD Annunciator with beige trim with French for Canada stainless steel trim option surface mount box ivory finish protector required where annunciator communications and power wiring exits and enters a refer to data sheet S2081 0016 for details to specifications on page 3 for details 4603 9101 Operator Information X 40 LCD READOUT green LED during normal conditions abnormal operating conditions PROGRAMMABLE Yellow LEDs with pushbutton switch and custom pocket STATUS INDICATOR LEDs provide system status in addition to LCD information LEDs flash to the condition and then when acknowledged on steady until reset Fire Alarm and Priority 2 are red System Supervisory System Trouble Alarm Silenced are yellow Power On is green 2 TIME time of last of event being displayed displays current when viewing status ACK FIRE ALARM acknowledges Fire Alarm condition and silences the and all annunciator tone alerts ACK PRIORITY 2 acknowledges Priority 2 Alarm condition and silences panel and all annunciator tone alerts ACK acknowledges System conditions and silences the and all annunciator tone alerts RESET restores panel to normal all alarmed inputs returned to normal ENABLE all switch functions is removable only in position SILENCE causes audible and notification appliances to be default operation may be through panel programming for with local requirements ACK acknowledges Troubles and silences the and all annunciator tone alerts 8 2016 4603 9101 LCD Annunciator Specifications additional information refer to Installation Instructions 579 979 Operating Specifications Operating Current Standby Current Current Temperature Range Humidity Range Capacity RUI Output Requirements to 32 VDC system supplied mA with LED backlighting on mA during battery backup LED backlighting is turned off after 30 seconds without activity mA maximum LED backlighting is on and tone alert is sounding to 120 F 0 to 49 C to 93 RH non condensing at 100 F 38 C RUI Remote Unit Interface external annunciator communications line SLC signaling circuit to 31 remote annunciators MINIPLEX transponders per channel including the LCD Annunciator the 4602 9101 Status Command Unit SCU and Remote Command Unit RCU refer to data sheet S4100 0031 for 4100ES information Wiring Type Unshielded twisted pair UTP 18 AWG 0.82 mm2 for most applications see below Characteristics 0.58 580 nF maximum capacitance between conductors 35 maximum total resistance Wiring that leaves the building Also requires Isolated Loop Circuit Protectors on Data Applications Shielded Pair STP end refer to data sheet S2081 0007 for 2081 9027 200 mA or for 2081 9028 5 A Wiring run in 500 ft 152 m or more of conduit Wiring closely bundled with standard IDNet communications or TrueAlert communications not required when run with IDNet B wiring Up to 10,000 ft 3048 m total wiring up to 2500 ft 762 m to farthest device X wiring distance Up to 2500 ft 762 m Wiring Wiring Information General Conduit Entrance Dimensions Trim Finish Optional Trim to 12 AWG 0.82 mm2 to 3.31 mm2 wires for 24 VDC system power dedicated earth ground connection to the electrical box is required for proper ESD EMI protection wire in accordance with NFPA 70 National Electrical Code 250 entrance must be located a minimum of 2 70 mm from the front of the to c