Simplex True alarm Analog Sensing Sounder Base 4098-9794 for use with TrueAlarm Photoelectric Sensors; S4098-0028
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-true-alarm-analog-sensing-sounder-base-4098-9794-for-use-with-truealarm-photoelectric-sensors-s4098-0028-0928367145.pdf |
---|---|
Type | |
Size | 635.63 KB |
Downloads |
Text Preview
ULC CSFM Listed FM Approved NYC Acceptance Analog Sensing Sounder Base 4098 9794 for use with Photoelectric and Heat Sensors TrueAlarm sensor base with built in alarm sounder Piezoelectric sounder provides high output 88 dBA low current requirements 20 mA For use with interchangeable TrueAlarm photoelectric heat sensors ordered separately Operation is for ceiling or wall mounting operation details Powered from 24 VDC or from a compatible Appliance Circuit NAC Synchronized via communications or by the NAC if powered Sounder can be manually activated from the control panel Sensor and sounder operation is listed to UL Standard 268 Sounder operation is also listed to UL Standard 464 an audible notification appliance analog sensing operation Analog sensor information is digitally communicated the control panel via IDNet or MAPNET II communications Sensor information is processed by the control panel determine sensor status use with the following Simplex products 4007ES 4010 4010ES 4100ES and 4100U Series panels and 4008 Series control panels with feature set refer to data sheet S4008 0001 for 4020 4100 and 4120 Series control panels and Transponders equipped for MAPNET II features Louvered smoke sensor design enhances smoke by directing flow to chamber entrance areas minimally visible when ceiling mounted Designed for EMI compatibility Magnetic test feature is provided Optional accessories include remote LED alarm and output relays base reference For standard bases refer to data sheet S4098 0019 For isolator bases refer to data sheet S4098 0025 For photo heat sensors refer to data sheet S4098 0024 address and S4098 0033 dual address This product has been approved by the California State Fire Marshal CSFM pursuant to Section of the California Health and Safety Code See CSFM Listings 7300 0026 217 and for allowable values and or conditions concerning material presented in this Accepted for use City of New York Department of Buildings MEA35 93E Additional may be applicable contact your local Simplex product supplier for the latest status Listings approvals under Simplex Time Recorder Co are the property of Tyco Fire Protection Total quantity of sounder bases available for coding on the same communications channel may vary panel application and availability of NAC power Refer to specific control panel requirements Photoelectric Sensor Mounted in Base 4098 9794 Analog Sensing Description bases combine an audible notification appliance a TrueAlarm analog sensor to provide Communication of Analog Sensing provide an analog measurement that is digitally to the control panel where it is analyzed an average value is determined and stored An alarm other abnormal condition is determined by comparing sensor present value against its average value Data Evaluation Monitoring each sensor value provides a software filtering averaging that compensates for environmental factors dust etc and component aging providing an accurate for evaluating new activity The result is a reduction in the probability of false or alarms caused by shifts in sensitivity either up down Panel Selection Peak activity per sensor is to assist in evaluating specific locations The alarm point for each TrueAlarm sensor is determined at the panel selectable as more or less sensitive as the application requires Selection Alarm set points can be for timed automatic sensitivity selection as more sensitive at night less sensitive during Control panel programming can also provide operation per sensor For example a 0.2 may cause a warning to prompt investigation while a level may initiate an alarm Alarm and Trouble LED Indication Each base LED pulses to indicate communications the panel If the control panel determines that a is in alarm or that it is dirty or has some other type trouble the details are annunciated at the control panel that sensor base LED will be turned on steadily a system alarm the control panel will control the such that an LED indicating a trouble will return to to help identify the alarmed sensors 1 2015 Additional Sounder Base Features mounted address selection allows the address remain with its programmed location when the sensor removed for service or type change Access is from the under the removable sensor sensor type identification provides sensitivity when substituting sensor types sensor types can be easily interchanged to meet location requirements This feature also allows sensor substitution during building When conditions are temporarily dusty of covering the smoke sensors causing them to be heat sensors may be installed without the control panel red LED indicates power on by pulsing or or trouble when steady on The exact status is at the fire alarm control panel alarm control panel provides Peak value logging allowing accurate analysis of each for individual sensitivity selection Sensitivity monitoring satisfying NFPA 72 sensitivity requirements automatic individual sensor check verifies sensor integrity Automatic environmental compensation multi stage operation and display of sensitivity directly in per foot Ability to display and print detailed sensor in plain English language Accessories LED Annunciation Relay activates when LED is on steady indicating a local alarm or trouble are DPDT rated 2 A 30 VDC 1 2 A VAC for transient suppressed loads requires external VDC coil power Remote red LED Alarm Indicator mounts on single gang box to provide status indications where the location may not be readily visible Remote LED Alarm Indicator Mounting Reference Box Requirements boxes are by others relay 4 octagonal or 4 square 1 1 2 deep single gang deep relay 4 octagonal or 4 square 1 1 2 deep with 1 1 2 ring 102 mm Square Box mount reference 102 mm Octagonal Box 38 mm box depth Single gang plate RACO 787 or equal is when using 4 box by others mount reference mount even with final or with up to 1 4 6.4 mm maximum recess 4098 9822 Relay in base electrical box requires additional see notes below size X 1 1 2 X 1 mm X 38 mm X 25.4 mm 3.75 cubic inches Dia 1 4 thick mm Adapter Plate required for mounting surface mounted boxes mounts inverted 164 mm status output louvers from front to side sensor shown for reference Review actual wire size wire count box type and whether 4098 9822 relay is used before determining box size Mounting to flush mounted box also fits single gang handy box 2 1 8 51 mm deep if wiring allows Not applicable if 4098 9822 relay is used For surface mounted boxes use 4 square box with single gang adapter plate RACO No 787 or equal by others or 4 octagonal box both require 4098 9832 Adapter Plate When 4098 9822 relay is used mount relay in electrical box and use 1 1 2 extension ring by others on 4 square or octagonal box of 1 1 2 or 2 1 8 depth as required Refer to Installation Instructions 574 707 for additional information 1 2015 TrueAlarm Analog Sensor Features against rear air flow entry are EMI RFI shielded sensors Selectable rate compensated fixed temperature with or without rate of rise operation Rated spacing distance between sensors Temp F C F C ULC ft x 60 ft m ft x 40 ft m Spacing Either Fixed Setting ft x 20 ft 6.1 m for fixed only RTI Quick ft x 50 ft 15.2 m for fixed with either rate of rise RTI Ultra Fast Sensors Photoe