Simplex TrueAlarm Analog Sensing, 4098-9846 Sensor Guard for TrueAlarm Photoelectric Sensor 4098-9714
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truealarm-analog-sensing-4098-9846-sensor-guard-for-truealarm-photoelectric-sensor-4098-9714-2510976843.pdf |
---|---|
Type | |
Size | 701.43 KB |
Downloads |
Text Preview
ULC CSFM Listed Simplex TrueAlarm sensors and ordered separately 4098 9714 Photoelectric sensor 4098 9754 Multi Sensor Photoelectric and Heat 4098 9733 Heat Sensor 4098 9792 Standard Sensor Base 4098 9791 Relay Control Base 4098 9789 LED Output Base 4098 9793 IDNet Isolator Base features For ceiling or wall mounted sensor applications Combines accurate individually addressable analog and or heat sensing with physical protection TrueAlarm analog sensing provides compensation for flow restriction by providing maintained high Photoelectric smoke sensitivity is selectable from 0.5 1.5 ft at the fire alarm control panel The host control panel automatically compensates for shifts caused by contamination and reports dirty devices UL listed to Standard 268 URRQ and 521 UQKE ULC listed to Standard S529 URRQC and S530 options Standard mounting of 4098 9846 is for use with flush electrical boxes Extension box 4098 9847 is required for mounting to mounted electrical box resistant design Heavy duty steel construction single wall Tamper resistant grill mounting screws Guard 4098 9846 combines the sensitivity maintained accuracy of Simplex TrueAlarm sensors a rugged tamper resistant enclosure Typical are Correctional Detention facilities Mental Industrial areas Educational facilities and many other locations where the smoke may be intentionally or accidentally subjected to Reference With this combination the sensor be located directly in the ceiling of a detention cell or area and can provide accurate and quick sensing smoke and or heat conditions Additionally after the tamper resistant hardware the sensor is accessible for cleaning when the TrueAlarm automatically identifies the need for maintenance Analog Sensing Sensor Guard for Sensors TrueAlarm Sensor Guard Mounting Reference mount shown with optional surface mount see page 2 for details Material Pattern Frame Mounting Screws Removal Tool to page 2 wall construction 22 gauge 0.025 thick 0.64 mm 6.4 mm hex holes staggered 1 4 6.4 mm centers at corners baked enamel 1 4 see page 2 tamper resistant screws hex head supplied with Secure Hex Key separately Reference Sensors and Bases 4098 9754 IDNet Isolator Base This product has been approved by the California State Fire Marshal CSFM pursuant to Sheet 13144.1 of the California Health and Safety Code See CSFM Listing for allowable values and or conditions concerning material presented in this It is subject to re examination revision and possible cancellation This product not approved by FM as of document revision date Additional listings may be contact your local Simplex product supplier for the latest status Listings and under Simplex Time Recorder Co are the property of Tyco Fire Protection 12 2016 Mounting Information IMPORTANT See Warning and Installation Notes Below box 4 square or 4 octagonal supplied others see installation notes below for box information box using 3M Weatherban 606 or equal Photoelectric Sensor Multi Sensor or 4098 9733 Sensor ordered separately warning below mm mm mm mm mm Adapter Plate ordered separately when electrical box is surface base 4098 9789 4098 9791 4098 9792 or ordered separately see installation notes additional information Extension Box ordered separately when electrical box is surface bolts are supplied to fasten guard to Extension Box Do not use with flush mounted box guard mounting frame with 4098 9846 1 4 diameter mounting bolts hardware mounting frame to ceiling or wall is by others Extension Box includes to attach the guard frame guard cover with 4098 9846 mm tamper resistant supplied 76 mm mm mm NFPA 72 the National Fire Alarm and Signaling Code 5.4.3 2007 Edition subject to mechanical an initiating device shall be protected A mechanical used to protect a smoke heat or radiant energy shall be listed for use with the detector Sensor guard is for use only with a Simplex 4098 9714 Sensor or a 4098 9754 Photo Heat Sensor with restricted sensitivity range of 0.5 to 1.5 per foot or with a 4098 9733 Heat Sensor and for use with sensor bases 4098 9789 4098 9791 4098 9792 or This will ensure the sensor will activate within the listed obscuration range when mounted in the sensor guard NOTE For proper performance follow instructions and review sensor and guard carefully Wall mounting may not be appropriate institutional or detention applications Issue The presence of debris on the sensor grill will significantly restrict airflow into the sensor It is that increased visual maintenance be performed to proper operation Notes For additional information refer to Installation 579 116 Ceiling mount is shown above for reference if installations can be wall mounted Flush mounted electrical box must be flush to surface recessed no more than 1 4 6.4 mm Select box to accommodate selected base options For surface electrical box mounting only Extension 4098 9847 and Adapter Plate 4098 9832 are required ordered separately Electrical box be 1 1 2 deep NOTE Do not use Extension 4098 9847 with FLUSH mounted electrical sensor will not be properly positioned to wall or ceiling requires solid use 1 4 bolts by others Hardware is with the 4098 9847 Extension Box for the sensor guard frame SIMPLEX and the product names listed in this material are marks and or registered marks Unauthorized use is strictly prohibited NFPA 72 and National Fire Alarm are trademarks of the National Fire Protection Association NFPA Weatherban and 3M are trademarks of the Minnesota Mining and Manufacturing company 3M Fire Protection Products Westminster MA 01441 0001 USA 12 2016 2016 Tyco Fire Protection Products All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice