Simplex TrueAlarm Analog Sensing, Air Aspiration Addressable Duct Smoke Detection with TrueAlarm Photoelectric Sensors

File Preview
File Preview
Click below to download for free

Text Preview

TrueAlarm Analog Sensing Aspiration Addressable Duct Smoke Detection with TrueAlarm Photoelectric Sensors Listed ULC Listed CSFM Features aspiration duct smoke detection system provides remote location for ducts with difficult service access Available as either a single or dual inlet detection system includes a photoelectric sensor and addressable base per inlet For use with Simplex addressable fire alarm control units FACUs IDNet or MAPNET II communications Supports remote housing up to 82 ft 25 m with 1.05 in 26.7 mm Supports remote housing up to 50 ft 15 m with 3 4 in 19 mm O D rigid pipe tubing controlled aspiration system provides Adjustable air speed settings for easy setup Monitoring of airflow from the HVAC ducts Integral indicators located under the front cover for convenient and status indications Easily accessible air filter element 4098 XAD 110 Single inlet housing with one smoke sensor Duct probe kit 4098 XAD 210 Dual inlet housing with two smoke sensors one per inlet Duct probe kit Compatability with ducts wider than 90 in 2286 mm features UL listed to Standards 268 and 268A ULC listed to Standard S529 Requires separate 24 VDC power Duct sensor housing with supervised output for multiple remote relays Relay output control through programming at the FACU that can be or deactivated manually in response to a separate alarm or input or can be bypassed for unobtrusive system testing functions on interface board accessed by removing the Remote functional smoke testing Magnetic testing feature for alarm initiation at housing tubes ordered separately Available in multiple lengths to match duct size 1 Single inlet Duct Housing duct probe kit not shown 2 Dual inlet Duct Housing duct probe kit not shown module options ordered separately Remote red status alarm LED 2098 9808 Remote test station with LED 2098 9806 4098 9843 remote relays Please note that smoke detection in air ducts indicates the of smoke in the duct Smoke detection in air ducts does not smoke detection requirements for open areas or other non applications located smoke sensors For smoke detection in HVAC or other area locations that are inconvenient or difficult to access smoke sensing systems mount the sensor remotely and sample air using traditional air aspiration techniques Smoke Sensing Mounted in the smoke sensor housings a Simplex TrueAlarm photoelectric smoke sensor that samples the and reports its analog monitoring information to the FACU for This provides the TrueAlarm smoke sensing feature set with environmental compensation including Dirty Excessively and Almost Dirty trouble detection Aspiration Air draws from the ducts through sampling holes in sampling tubes Sampled air then filters before analysis the TrueAlarm sensor Single or dual sensor versions are available These products have been approved by the California State Fire Marshal CSFM pursuant to Section 13144.1 of the California Health and Safety Code See CSFM Listing 3240 0026.0367 for allowable and or conditions concerning material presented in this document It is subject to re examination revision and possible cancellation Additional listings may be applicable contact your local product supplier for the latest status Rev 4 11 2019 Aspiration Addressable Duct Smoke Detection with TrueAlarm Photoelectric Sensors 4 Test Station Fire Alarm Control Unit Features Individual smoke sensitivity selection Sensitivity monitoring that meets NFPA 72 and CAN ULC S536 S537 testing requirements Peak value logging allows accurate analysis for sensitivity selection Automatic individual sensor calibration check every 60 seconds to sensor integrity Automatic environmental compensation Smoke sensitivity displays in percent per foot Displays and prints easy to understand sensor information 4098 9843 Remote relay is under unit control for ON OFF or override Supervision A high performance aspirator with programmable and monitoring circuitry provides airflow Airflow displays on a ten bar graph under the front cover that can be adjusted for high low flow thresholds Flow failure reports as a trouble to the FACU for humid environments An optional water trap with a ball can be ordered The water from condensation that accumulates in clear water trap is clearly visible and can be drained with a ball valve before nuisance alarms or troubles develop due to moisture configuration programming requirements Function to setup the Simplex XAD are located on the housing The XAD minimal settings the aspirator speed and air flow monitoring configured during commissioning phase without the use of special Unlike other aspirating systems no special engineering software is to design the Simplex XAD detection system air filter element The Simplex XAD includes a air inlet filter It is recommended that the filter element changed every 12 months or as necessary such as when the dust impede airflow The frequency of filter replacement depends on conditions Test Capability You can test the XAD at the remote location it is mounted A convenient test port is located in the inlet tubes that a functional test that requires smoke or simulated smoke to the detection chamber can be initiated TrueAlarm Sensor Operation Communication of Analog Sensing Analog information from sensor transmits to the control unit for analysis The system stores tracks sensor input as an average value and uses this information a reference to detect an alarm or abnormal condition Data Evaluation The sytem monitors each photoelectric average value and compensates for environmental factors such dust dirt or component aging This provides an accurate reference evaluating new activity and reduces the probability of false alarms Unit Selection The system stores peak activity for each sensor evaluate specific locations The alarm set point for each sensor is at the control unit selectable as the individual application Status LED Each sensor s red status LED located on the interface board accessed by removing the cover pulses to communications with the unit If the control unit determines a sensor is in alarm or that it is dirty or has some other type of the details are annunciated at the control unit and that sensor status LED turns on steadily During a system alarm any LEDs indicate a trouble will pulse to identify an alarmed sensor Status Alarm LEDs track the operation of the duct sensor LED See Figure 3 and Figure 4 3 Remote Status Alarm Indicator 2 Rev 4 11 2019 Aspiration Addressable Duct Smoke Detection with TrueAlarm Photoelectric Sensors Product Selection 1 Single inlet Duct Detection Application Tubes Select one pair of single core flex tubes either 25 ft or 50 ft length sensor housing with single duct probe kit LF42241 see Figure 5 for included equipment Table 2 ft 7.5 m Flexible single core tubing ft 15m Flexible single core tubing water trap kit Optional recommended for humid environments 2 Sampling Tubes Selection Chart Ordered Separately Per Duct Width Select One Duct Width Up to in 686 mm Kit Required in 1372 mm in 2286 mm one 18 in 457 mm Inlet Sampling Tube 2 Holes and one 8 in 203 mm Tube 2 Holes one 36 in 914 mm Inlet Sampling Tube 3 Holes and one 8 in 203 mm Tube 3 Holes one 60 in 1524 mm Inlet Sampling Tube 4 Holes and one 8 in 203 mm Tube 4 Holes 3 Dual inlet Duct Detection Application Tubes Dual inlet Duct detection requires three single core flex tubes select either 25 ft or 50 ft length sensor housing with dual duct probe kit LF42243 see Figure 6 for included equipment Table 4 ft 7.5 m Flexible single core tubing ft 15m Flexible single core tubing water trap kit Optional recommended for humid environments Duct Width Up to in 686 mm 4 Sampling Tubes Selection Chart Ordered Separately Per Duct Width Select One Kit Required

Related Files