Simplex TrueAlarm Analog Sensors Model 4098-9793, IDNet Isolator Base
File Preview
Click below to download for free
Click below to download for free
File Data
Name | simplex-truealarm-analog-sensors-model-4098-9793-idnet-isolator-base-0581273496.pdf |
---|---|
Type | |
Size | 895.09 KB |
Downloads |
Text Preview
ULC CSFM Listed FM Approved NYC Acceptance Analog Sensing TrueAlarm Analog Sensors 4098 9793 IDNet Isolator Base base for TrueAlarm analog sensors IDNet addressable communications Compatible with Simplex 4007ES 4008 4010 4100ES or 4100U Series fire alarm control IDNet Signaling Line Circuits SLCs providing IDNet IDNet 1 IDNet 2 or IDNet 2 2 output see additional information on pages 2 and 3 Can be installed up to 250 total allowing isolation to the device level 200 total with 4008 Operation is for ceiling or wall mounting Base mounted LED indicates sensor status Designed for EMI compatibility UL listed to Standard 268 ULC listed to Standard S529 circuit wiring isolation is automatically separated from output when an communications short circuit occurs fault isolation reduces time to fix wiring Built in control panel diagnostics assist in locating earth conditions the most common installation wiring base 4098 9793 is compatible with Photoelectric sensor model 4098 9714 Heat sensor model 4098 9733 Multi sensor model 4098 9754 Class B or Class A wiring Communications are received from either input or output bases with Class A wiring to isolate short while still operating their sensors Sensing and IDNet communication The 4098 9793 IDNet Communications Base provides Simplex TrueAlarm analog sensor and also provides IDNet communications to improve installation convenience and increase integrity Isolation is automatically activated at the when an output short circuit is detected and isolation also be selected per base manually from the control to assist with troubleshooting wiring problems Isolator bases power up in isolation mode are directed to connect by the control panel If the wiring is acceptable the isolator base will connect the rest of the circuit If the output wiring is shorted isolator remains isolated This product is listed by the California State Fire Marshal CSFM pursuant to Section of the California Health and Safety Code See CSFM Listing 7300 0026 0217 allowable values and or conditions concerning material presented in this document for use City of New York Department of Buildings MEA35 93E Additional may be applicable contact your local Simplex product supplier for the latest Listings and approvals under Simplex Time Recorder Co are the property of Fire Protection Products 24V IDNET PW R PW R TIME RECORDER CO ONITOR ZAM CLASS B INSTR 574 183 CODE addressable device sensor Isolator Base TrueAlarm Sensor DOWN station sensor Channel with a Single 4098 9793 Isolator Base Fire Alarm Control Panel shown for reference Continued Tracking The isolator reports back to the panel it is in isolator mode and the extent of shorted is reported back to the panel by identifying device that are not communicating Isolators are sequentially to low number addresses to expedite Line Circuit SLC power up Refer to Instructions 574 709 and 574 707 for information Faults During installation earth faults often and finding these faults normally requires extensive disconnection With the 4098 9793 isolator base suspected to have earth faults can be isolated to in their discovery and repair 10 2016 Multi Floor Isolator Example 1 one line diagram on this page shows a multiple floor with Class B IDNet communications for each starting at an isolator base If any floor wiring the isolator base should experience a short circuit floor can be individually separated from the next the short circuit from disabling the entire communications wiring the event of an earth connection each floor can be isolated using the built in control panel With individual floor control the earth fault be isolated to the floor level to narrow the search area floor floor floor floor communications 2 wire wiring notes B riser IDNet IDNet Isolator with TrueAlarm sensor Notes Operation of the 4090 9793 TrueAlarm Isolator base requires to a compatible 4007ES 4008 4010 4010ES or 4100U IDNet communications channel NOTE The 4100 3103 Panel Mounted Quad Isolator is only with MAPNET II Remote Isolators Maximum line resistance between the panel and an isolator between two isolators is 10 or 780 ft 238 m with AWG wire This is a one line drawing showing only IDNet communications Some IDNet devices require additional wiring for power Refer specific devices for details Simplex Fire Alarm Panel model 4010ES for reference 10 2016 Multi Floor Isolator Example 2 illustration below is a modification of Example 1 for each floor has an additional isolator base and IDNet circuit is wired as a Class A connection With addition of these isolator bases wiring between floors be better protected in the event of a short circuit in the event of an earth connection the additional base per floor allows earth fault isolation to be with better precision Assistance Communications from an 2 IDNet 2 2 or IDNet output provide individual circuit isolation and allow individual output control provide assistance in locating wiring faults When wiring Class A IDNet communications by IDNet or IDNet 1 outputs locate isolators the first and last devices in the loop close to the panel provide loop short circuit isolation operation as shown floor floor floor floor Wiring Example A riser with Isolator using Class B taps device device communications 2 wire Wiring Note 3 A Circuit IDNet IDNet Isolator with TrueAlarm sensor Notes Operation of the 4098 9793 TrueAlarm Isolator requires connection to a compatible 4008 4010 4010ES 4100ES or IDNet communications channel NOTE The 4100 3103 Panel Mounted Quad is compatible only with MAPNET II Isolators For Class A communications from IDNet or 1 outputs locate IDNet Isolators as the and last device in the loop close to the panel optimize loop short circuit protection This is required with IDNet 2 IDNet 2 2 or outputs Maximum line resistance between the panel and isolator and between two isolators is 10 or ft 238 m with 18 AWG wire This is a one line drawing showing only IDNet wiring Some IDNet devices require additional wiring for Refer to specific devices for details Simplex Fire Alarm Panel model 4100ES for reference 10 2016 Specifications for additional information refer to Installation Instructions 574 709 and 574 707 and Communications communications one address per base line resistance between panel and isolator or between isolators is 10 ohms AWG 0.82 mm2 780 ft 238 m terminals for in out wiring 18 to 14 AWG 0.82 to 2.08 mm2 Specification Connections Listed Temperature Range 32 F to 100 F 0 C to 38 C Temperature Range 15 F to 122 F 9 C to 50 C Temperature Range Range Color F to 140 F 18 C to 60 C to 95 RH from 32 F to 122 F 0 C to 50 C White 4098 9793 or Black 4098 9777 Photoelectric Sensor Photoelectric Sensor Heat Sensor Heat Sensor TrueSense Multi Sensor TrueSense Multi Sensor Remote IDNet Isolator Module not available with 4010 control panels S4090 0005 24 V Addressable Power Isolator not available with 4008 or 4010 panels Sheet Compatibility are ordered Isolator Products