Simplex TrueAlarm Fire Alarm Sys PC Products for Life Safety 4190-9008 BACpac Portal

File Preview
File Preview
Click below to download for free

Text Preview

UL Listed BACpac portal provides fire alarm status using the ASHRAE BACnet automation communication protocol protocol reference BACnet stands for Building Automation Control Reference ANSI ASHRAE standard 135 1995 To fire alarm system via RS 232 computer output port Output port provides RS 232 Point to Point BACnet portal is pre programmed Up to 600 status changes monitor point status can be from the fire alarm control panel Custom programming is easily accomplished at the alarm control panel is mounted separately from fire alarm panel Cabinet is NEMA 1 Portal is UL Listed to Standard 2017 Category power is 120 VAC Signal Appliances Miscellaneous Simplex fire alarm control panels Simplex 4100U Series fire alarm control panels and Display Units NDU 4020 4100 and 4120 Series fire alarm panels and Network Display Units NDU Software revision updating may be required 4190 9008 BACpac portal provides a supplementary interface that converts computer terminal from a compatible Simplex fire alarm control into the building automation protocol of BACnet this portal status information from the fire alarm panel can be provided to other components of the automation network with the detail and format required This allows the other to properly respond to fire alarm system activity addition to the primary fire alarm response that is under control of the fire alarm control panel Fire Alarm Systems PC Products for Life Safety BACpac Portal LAN System Controllers with gateway router interfaces communications protocol DOWN DOWN alarm initiating devices Control Control Fire Alarm Panel Alarm System Control Alarm SYST EM IS NOR MAL 02 15pm Mon 8 Mar 99 RE LA RM STEM UPE RVI SOR Y YSTE M UBLE LA RM LE NCE D WE R LA RM CK PV UBLE K LA RM ILEN CE TEM ESE T IRE A LA RM ONTR OL I SC O NN EC T WER B EFO R E VI C IN G Control Building Automation LAN with Fire Alarm Control Panel and BACpac Portal document is a summary of the flexibility available BACnet communications Please contact your local product supplier for further information your specific application This product was not ULC or CSFM listed or approved by FM or accepted by MEA NYC as document revision date Additional listings may be applicable contact your local Simplex supplier for the latest status Listings and approvals under Simplex Time Recorder are the property of Tyco Safety Products Westminster 12 2005 Responsibilities Detection and Alarm Systems are distributed buildings to monitor for indications of the of smoke or fire When a fire alarm condition is the fire alarm system communicates that with sufficient detail to allow the proper fire to begin The fire alarm system may perform control functions such as fan shutdown and elevator or those actions may be performed by other that also handle those functions for normal as well as for abnormal conditions Automation Systems As buildings increase size and complexity control of the electrical and systems requires coordination This process evolved into the general category of Building Systems and includes systems such as heating and air conditioning HVAC elevator security controls lighting controls and other building functions responses to fire alarm system status changes include HVAC fan control operation elevator lighting control and security system awareness examples could include turning on lighting needed aiming security cameras on specific areas door release and implementing detailed fan and or pressurization instructions Communications Between Systems Building need to be integrated as fully as possible communications have included simple relay proprietary and complicated interface devices as well as using a single supplier for all of the automation functions Each of these compromises its limitations the Simplex BACpac portal the common building language of the BACnet protocol allows a Simplex alarm system to be considered based upon its fire alarm and not simply on its interconnection capability Example example to the right shows how a smoldering fire on the first floor can be detected by the fire alarm panel processed by the BACpac portal and then to the building automation system using the BACnet It is the responsibility of the fire alarm control to initiate the required notification and related fire However when connected to a BACpac portal fire alarm system can make status information to the other building systems allowing them to informed about facility fire detection activity FLOOR SMOKE ALARM protocol format Instance 1 4190 9008 Portal terminal format M1 1 IS NORMAL am 11 DEC 00 S STEM WARNINGS Power Alarm 2 Alarm Silenced T U W X Alarm 2 ore enu evious xt B C K L E F IG N O O 0 H I Q R DNet Z or Warning Condi tion indicator flashing Tone On to Acknowledge View Events ACK located under flas hing indicator operation until all events are acknowledged tone will silence to Silence Building Signals Alarm Silence to Reset System System Reset Ack to silence tone device Operating Instructions M1 1 Control fire Alarm Flow from Fire Alarm Control Panel to Portal to Building Automation Systems 12 2005 BACnet Protocol Implementation Conformance Statement PICS Details Conformance Class Supported 3 Functional Groups Supported Objects Supported Clocks Reinitialize Device Communications Binary input No Writeable Properties Binary Output Present Value Writeable Properties Binary Value Present Value Writeable Properties Device Link Layer Options RS 232 baud rates to 38,400 Sets Supported X3.4 Functionality Segmented Requests not supported Segmented Responses not supported Standard Application Services Supported SERVICE REQUESTS REQUESTS Property Property Multiple Property Property Multiple 12 2005 Specifications Power Input Output Range mA 120 VAC 60 Hz Class 2 input transformer rated 40 VA type RS 232 ASCII data from fire alarm control panel via computer terminal port Pluggable terminal block connections type RS 232 communications formatted with BACnet protocol Fixed terminal block connections Temperature Range F to 113 cid 113 F 0 cid 113 C to 45 cid 113 C to 95 RH from 32 cid 113 F to 122 cid 113 F 0 cid 113 C to 50 cid 113 C non condensing 1 enclosure UL and CSA listed Hoffman Cabinet catalog A HE12X12X4 Portal Electronic Module voltage UL listed to standard 916 Open Energy Management Equipment Color Dimensions to diagram below

Related Files