Simplex TrueAlarm Fire Alarm Systems; Fire Alarm Network Annunciators; TrueSite Graphic Annunciator; for International Projects [For INTERNATIONAL USE ONLY];

File Preview
File Preview
Click below to download for free

Text Preview

ULC and CSFM Listed Approved Graphic Annunciator general features Simplex fire alarm network connected graphical Supports standard fire service annunciation icons to firefighter and first responders with critical fire information Custom alarm and system messages can intuitively emergency responders important information locations contact information etc can be presented Color graphical annunciation capacity for up to points Floatable and dockable windows allows windows to be fixed docked or floatable Password Security supports 8 to 16 alphanumeric with configurable lockout for quantity of attempts Quad monitor support allows multiple active windows as putting the Alarm List Window on one monitor the Graphics Window on another with up to 4 total monitors Pan and zoom features allow precise dynamic within a graphic screen for rapid and selection of the area of interest Configurable coverage zones allow user defined areas zones within a graphics screen to be highlighted to the area of activity without zooming into the of interest Auto jump allows the screen view to automatically to a graphic at a predetermined zoom level with the device centered on the screen alternately the can be selected to auto jump to the Alarm List Captive or Non Captive modes support dedicated operation captive or annunciator operation other Windows applications word processing etc where annunciator activity takes non captive Extensive historical logging up to 500,000 events is compatible with spreadsheet and database for report customization Multiple password controlled operator levels with Available optional connections for printers or other feature access systems Operating Systems Compatible with Windows 7 10 or Enterprise listings UL 864 and ULC S527 as Control Unit Annunciator Fire Alarm Systems Fire Alarm Network Annunciators Graphic Annunciators Version 4.02 Graphic Annunciator optional second monitor expanded desktop shown annunciator system features TrueSite Workstation Mobile Client allows iOS and Android devices to access system Export to XML allows TrueSite Workstation data to be exported for report generation and customization Node Name supports including a description of the building or area associated with a point in the views and reports Web Browser Command Link enables the ability to call up an external web page or link web cam with a single command button on a graphic screen RAID 1 Support provides a real time image on secondary hard drive Operation will automatically to the alternate drive on a drive failure without of operation RAID support is available to systems do not use the Backup Utility Backup Utility can be configured to automatically specified directories including TSW job data the secondary hard drive The Backup utility is to systems that do not use RAID Sound files WAV can be used to create custom audible annunciation using local onboard speakers Fahrenheit or Celsius temperatures can be displayed for showing heat sensor temperatures screens details Over 30,000 custom field generated and edited graphic capacity is available Multiple import and export formats are supported refer page 4 for details Fire Alarm Network capabilities Multiple annunciators can be nodes on the same fire network to provide redundant operations for survivability Connect to up to seven 7 separate network loops Graphical diagnostic tools identify network node and status Provides event printing with compatible printer or print of status and service report information print graphic screens see page 7 for printing See CSFM Listing 7300 0026 323 for allowable values and or conditions concerning presented in this document Additional listings may be applicable contact your Simplex product supplier for the latest status Listings and approvals under Simplex Recorder Co are the property of Tyco Fire Protection Products 1 2017 Product Image Reference Graphics not to scale Desktop Monitor Monitor PC Features Continued Fire Alarm Network capabilities Compatible with IMS Information Management and GCC Graphic Command Center on the fire alarm network 2120 Multiplex Serial Line Interface SLI allows to up to eight 2120 Multiplex systems computer and monitor options Computers are available as desktop or rack mount mouse operation and or touchscreen operation convenient user interface Desktop LCD widescreen high resolution LED backlit are 22 inch class 21.5 inch 546 mm diagonal 1920 x 1080 resolution and are available with without touchscreen Wall mount LCD widescreen high resolution are 42 inch 1067 mm diagonal provide x 1200 resolution and are available with or touchscreen Rack mount LCD high resolution monitors are 19 inch mm diagonal with touchscreen and provide x 1024 resolution Description Annunciation TrueSite Graphic provide annunciation and status display for Fire Alarm Networks using a personal computer graphical interface with a high resolution color When fire alarm network status changes the screen displays the type and location of the or other activity and the appropriate header appear In the historical log screen below in 1 Fire Priority 2 Supervisory and Trouble are shown with an active Trouble indicated Screens Figure 1 below is representative of log screen detail Figure 2 on page 4 is of a system graphic screen with icons the devices of interest Screen choices can be per system preference However when using optional monitors multiple windows can be simultaneously for operator convenience of Operation With touchscreen monitors the touches the screen area in alarm or uses the control to access a more detailed view of the zone or device With the proper password access operator has the ability to acknowledge alarm and conditions activate signal silence and perform reset directly from the workstation screens 1 2017 Continued Activity Timeout allows an monitor to revert to the login screen when the time period expires User Preferences appear when the user in Options include Font Size default or large Size small or large Interface Theme MS 2003 or System Floating Window Options select to show Menu bar or show Tool bar Log and List Details Figure 1 below historical log details The display format is similar the display for active list items such as the alarm list information can be sorted on screen by each shown number time date point name etc information can be reviewed on the screen or printed a local or remote system printer Response Custom alarm and trouble can be added and field edited to provide operator assistance Point specific information such as material storage and lists of people to notify can automatically or selectively displayed Password Control Multiple Access Levels Operator access level is during log in Select functional access to match training and responsibility of the operator Operators additional TrueSite Graphic Annunciator and fire alarm training may be qualified for access to more detail operators who are primarily concerned with immediate security a lower level access will provide the necessary for proper response but will not allow to areas beyond their training 1 TrueSite Workstation Sample Alarm Lists Screen 1 2017 Graphics Screens and Floor Plan Details Graphics screens can easily recognizable site plan and floor plan The level of detail can

Related Files