ULC CSFM Listed Approved Fire Alarm Systems Fire Alarm Network Annunciators Incident Commander Version 4.02 TrueSite Incident Commander provides 4100ES for the Simplex TrueSite Workstation All in one touchscreen computer monitor mounts in a cabinet and is powered from the fire alarm power supply including battery backup Seismic hardware 4100ES mounting with battery provides seismic area protection see page 4 High resolution touchscreen monitor Includes Windows 10 Enterprise 64 bit Hinged mounting bracket allows convenient service Available for desktop use operating at 120 VAC with included power supply module Incident Commander function summary Simplex fire alarm network connected graphical control Connects to the Simplex fire alarm Network as a node access to remote panel activity status and for a Notification System event or a fire alarm event can control of remote panel activity over the fire alarm Available TCP IP LAN WAN connections up to 20 clients can be connected to the server for multiple users with dedicated and listed Fire Alarm LAN listed remote clients can have control access Supports standard fire service annunciation icons to firefighter and first responders with critical fire information Custom alarm and system messages guide emergency with important information Color graphical annunciation and control capacity for to 100,000 points Floatable and dockable windows allows windows to be fixed docked or floatable Extensive historical logging up to 500,000 events with notations Password Security supports 8 to 16 alphanumeric with configurable lockout Optional interface to Digital Alarm Communicator DACR integrates multiple systems onto a Incident Commander Backup Utility can be configured to automatically backup directories including TSW job data to the hard drive The backup utility is available to that do not use RAID Multiple password controlled operator levels 3rd Party Interface open architecture solution provides information access for advanced users Available optional connections for printers or other systems Dual monitor support allows the Alarm List Window to on one monitor and the Graphics Window on the other Operating Systems Server and clients are compatible Windows 7 10 Professional or Enterprise also compatible with Windows 7 Home and Windows 10 Home 32 bit and 64 bit for options Incident Commander Mounts in Bay 2 of a 4100ES Panel shown with Master Controller TrueSite Incident Commander screens details Pan and zoom features allow precise navigation Configurable coverage zones allow highlighted areas of in user defined zones Auto jump allows the screen view to jump to a graphic or list menu Incident Commander system features TrueSite Workstation Mobile Client allows compatible and Android devices to access system information Export to XML feature allows TrueSite Workstation data to easily exported for report generation and customization Test Mode allows unobtrusive testing of selective devices nuisance interruptions Node Name allows a description of the specific building area associated with a point in views and reports Vector information to supervised remote clients select point event category panel or custom list Email generation is available to send updates to or to distribution lists with selectable content Sound files WAV can be used to create custom audible annunciation with Agency listed desktop PC model Fahrenheit or Celsius temperatures can be displayed Refer to pages 5 and 6 for specific product listing details CSFM Listing 7300 0026 323 listings may be applicable contact your local Simplex product supplier for the latest Listings and approvals under Simplex Time Recorder Co are the property of Tyco Fire Products 8 2017 system features Continued DACR Account Filter allows Historical Log Reports to Filtered by DACR Account for Quick Access and Operator Notes allows an operator to log operator notes with individual events for historical records retrieval Web Browser Command Link allows an external web or link web cam etc to be called with a single RAID 1 Support provides a real time image on secondary hard drive for enhanced life safety survivability RAID support is available to that do not use the Backup Utility listings UL 864 as Supervising Station Control Unit or ULC S527 as Fire Alarm System Annunciator UL 864 UUKL as Firefighter Smoke Control Station UL 2572 Mass Notification Systems as Supervising Control Unit or Annunciator see page 9 for UL 1076 as Proprietary Burglar Alarm Unit or UL 1610 as Central Station Burglar Alarm Control or Annunciator Fire Alarm Network capabilities Multiple TrueSite Incident Commanders and TrueSite can be nodes on the same fire alarm to provide redundant operations for improved Standard fire alarm network connection for wired or fiber media Graphical network diagnostic tools Set host service functions allow access to remote network data including individual TrueAlarm analog sensors Provides event printing with compatible printer view or of status and service report information and print screens see page 7 for printing details Please refer to TrueSite Workstation data sheet for additional operation detail TrueSite Incident Commander offers TrueSite operation in an all in one package providing touchscreen computer monitor hard drive and required connections in single assembly This allows within a 4100ES fire alarm control panel or annunciator with power supplied from the fire power supply and secondary batteries The all in computer is also available for desktop applications separate AC power Annunciation TrueSite Incident Commanders annunciation status display and control for Simplex Alarm Networks using a personal computer based interface with a high resolution color display buttons with realistic icons provide control specific to the operation being performed Clients For remote viewing of TrueSite Incident Server information remote clients are available connected using TCP IP LAN WAN Ethernet As discussed on pages 8 and 9 Remote can be annunciation only or capable of system when configured with agency listed hardware Description Continued DACR Compatible For systems requiring information remote control panels via DACTs Digital Alarm Transmitters Incident Commanders can be to communicate directly with a compatible DACR to data sheet S4190 0016 for more DACR details Incident Commander Operation Operation When fire alarm network status changes occur screen displays the type and location of the alarm or activity and the appropriate header buttons appear In historical log screen on page 3 Figure 1 Fire Priority 2 and Trouble buttons are shown with an active indicated Screens Figure 1 on page 3 is representative of historical view screen Figure 2 on page 4 is of a system graphic screen with icons the devices of interest Screen choices can be per system preference however when using an second monitor both screen types can be visible for convenience of Operation With touchscreen monitors the selects the area in alarm to access a more detailed of the alarmed zone or device Where control operation permitted by local listings the authority having jurisdiction Civil Defense or equal and with proper password the operator can acknowledge alarm and trouble activate signal silence and perform system reset from the Incident Commander screens Activity Timeout allows an unattended to revert to the login screen when the configured period expires Use

Related Files