Simplex TrueAlarm Fire Alarm Systems; Fire Alarm Network Annunciators; TrueSite Incident Commander Graphic Annunciator; For International Projects [For INTERNATIONAL USE ONLY];

File Preview
File Preview
Click below to download for free

Text Preview

ULC CSFM Listed Approved Fire Alarm Systems Fire Alarm Network Annunciators TrueSite Incident Graphic Annunciator Version 4.02 Incident Commander Graphic Annunciator 4100ES mounting for the Simplex Graphical Annunciator All in one touchscreen computer monitor mounts in 4100ES cabinet and is powered from the fire alarm power supply including battery backup Seismic hardware 4100ES mounting with battery provides seismic area protection see page 2 High resolution touchscreen monitor Includes Windows 10 Enterprise 64 bit Hinged mounting bracket allows convenient service Available for desktop use operating at 120 VAC with included power supply module Annunciator function summary Simplex fire alarm network connected graphical Connects to the Simplex fire alarm Network as a node access to remote panel activity status Supports standard fire service annunciation icons to firefighter and first responders with critical fire information Custom alarm and system messages HAZMAT contact information etc can intuitively guide responders Color graphical annunciation capacity for up to points Extensive historical logging up to 500,000 events Multiple password controlled operator levels Available optional connections for printers or other systems Backup Utility can be configured to automatically specified directories including TSW job data to secondary hard drive The backup utility is available systems that do not use RAID Password Security supports 8 to 16 alphanumeric with configurable lockout for quantity of failed Dual monitor support allows the Alarm List to be on monitor and the Graphics Window on the other Operating Systems Server and clients are compatible Windows 7 10 Professional or Enterprise also compatible with Windows 7 Home and Windows 10 Home 32 bit and 64 bit for options screens details Pan and zoom features allow precise navigation Configurable coverage zones allow user defined zones highlight the area of activity without zooming in Auto jump allows the screen view to jump to a graphic alarm list menu listings UL 864 and ULC S527 as Control Unit Annunciator See CSFM Listing 7300 0026 323 for allowable values and or conditions concerning presented in this document Additional listings may be applicable contact your Simplex product supplier for the latest status Listings and approvals under Simplex Recorder Co are the property of Tyco Fire Protection Products Incident Commander Graphic Annunciator in Bay 2 of a 4100ES Control Panel TrueSite Incident Commander Annunciator system features Continued Node Name allows a description of the specific building area associated with a point in views and reports TrueSite Workstation Mobile Client allows mobile devices to access system information Export to XML feature allows TrueSite Workstation to be easily exported Sound files WAV can be used to create custom status annunciation with PC model 4190 7014 Fahrenheit or Celsius temperatures can be displayed Web Browser Command Link allows an external web or link to be launched with a single command on a graphic screen RAID 1 Support provides a real time mirror image on a hard drive operation will automatically to the alternate drive on a drive failure without of operation RAID support is available to systems do not use the Backup Utility Fire Alarm Network capabilities Multiple Graphic Annunciators can be nodes on the fire alarm network for improved survivability Standard fire alarm network connection for wired or optic media Graphical network diagnostic tools Provides event printing with compatible printer view print of status and service report information and graphic screens see page 6 for printing details 1 2017 Description TrueSite Incident Commander Graphical offers TrueSite Graphical Annunciator in an all in one package providing a computer monitor hard drive and required connections all in single assembly This installation within a 4100ES fire alarm control or remote annunciator with power supplied from the alarm power supply and secondary batteries This is also available for desktop applications Annunciation Graphic Annunciators provide and status display for Simplex Fire Alarm using a personal computer based graphical with a high resolution color display Annunciator Operation Operation When fire alarm network status changes the screen displays the type and location of the or other activity and the appropriate header appear In the historical log screen on page 3 1 Fire Priority 2 Supervisory and Trouble are shown with an active Trouble indicated Screens Figure 1 on page 3 is representative a historical view screen Figure 2 on page 4 is of a system graphic screen with icons the devices of interest Screen choices can be per system preference however when using optional second monitor both screen types can be for operator convenience of Operation With touchscreen monitors the touches the screen area in alarm or uses the control to access a more detailed view of the zone or device With the proper password access operator has the ability to acknowledge alarm and conditions activate signal silence and perform reset directly from the Graphic Annunciator Activity Timeout allows an monitor to revert to the login screen when the time period expires User Preferences appear when the user in Options include Font Size default or large Size small or large Interface Theme MS 2003 or System Floating Window Options select to show Menu bar or show Tool bar Log and List Details Figure 1 on page 3 historical log details The display format is similar the display for active list items such as the alarm list information can be sorted on screen by each shown number time date point name etc information can be reviewed on the screen or printed a local or remote system printer Response Custom alarm and trouble can be added and field edited to provide operator assistance Point specific information such as material storage and lists of people to notify can automatically or selectively displayed Password Control Multiple Access Levels Operator access level is during log in Select functional access to match training and responsibility of the operator Operators additional TrueSite Graphic Annunciator and fire alarm training may be qualified for access to more detail operators who are primarily concerned with immediate security a lower level access will provide the necessary for proper response but will not allow to areas beyond their training Graphics Screens and Floor Plan Details Graphics screens can easily recognizable site plan and floor plan The level of detail can be customized for the facility to easily and accurately direct the to the immediate area of interest Screen Controls refer to graphic screen on 4 Icons can be added to identify the location and of the device of interest and the graphics control located at the top of the graphic can be used to and zoom for more precise detail Programmable zones can be added with selectable area and level A fixed area site plan key plan with action and screen locator can be added as shown Pan zoom are tracked by a green rectangle in the key plan Banner and Main Screen Background banner area shown with a Simplex logo in Figure 1 be customized bitmap area is 1750 x 68 pixels The screen background viewable prior to login can be with a bitmap of up to 1000 x 525 pixels Messages In addition to screen text or graphic the operator can be presented with specific messages that provide emergency response and directions These action messages are field edited for local requirements The appropriate message in a graphics screen would be found in an dialog box as shown on page 4 to Graphics or Alarm List Select

Related Files